Paperdoi:10.5281/zenodo.24176147

Hemodynamic Fidelity Across Anatomical Acquisition Sites: Stationary Blood Pressure Concordance and Dynamic Treadmill Heart Rate Tracking of a Plantar Multi-Sensor Platform Versus Finger and Wrist Photoplethysmography in 483 Adults

Venue listedDated Nov 12, 2026Added Nov 13, 2026

  • KW
  • EU
  • S

Authors: Kai Weng, Ethan Wei (listed affiliation: James Cook University, Singapore)

Journal of Human Science & Technology 1(2) Article 7 (ISSN 3144-6914), deposited on Zenodo

TL;DR

483 owners of Oura rings and WHOOP straps ran 30 minutes on a treadmill (8:00 min/mile). At minute 3 both lagged the reference HR by about 10–11 bpm. Across minutes 3–30, MAE was 8.4 bpm (Oura) and 7.7 bpm (WHOOP), and 24–33% of late-exercise readings were off by more than 10 bpm despite near-zero mean bias.

  • Form factor: ring, wrist, standing plantar platform

Abstract

ABSTRACTBackground: Resting agreement between wearable sensors and clinical reference standards does not establish fidelity during dynamic cardiovascular exertion, nor do software-imported blood pressure logs represent direct hemodynamic sensing. This study evaluated stationary blood pressure (BP) and heart rate (HR) agreement of a fixed ground-contact plantar platform alongside resting and dynamic treadmill HR tracking of finger-worn (OURA) and volar wrist-worn (WHOOP) photoplethysmography (PPG) devices in an established user cohort.

Methods: In 483 adults (267 women, 216 men) recruited from active personal owners with mature device baselines, the Deep Health® plantar platform (model PH-CS20C3) was compared concurrently against manual brachial auscultation and 60-second radial pulse counts during quiet stance. OURA and WHOOP HR outputs were evaluated at rest and across a 30-minute treadmill protocol (8:00 min/mile [7.5 mph], 2.0° incline) sampled at baseline and every 3 minutes (5,313 paired observations per wearable). Agreement was assessed via mean bias (MD), standard deviation of differences (SDD), Bland–Altman 95% limits of agreement (LoA), mean absolute error (MAE), root mean square error (RMSE), Lin’s concordance correlation coefficient (CCC), and 10,000-iteration participant-level bootstrap confidence intervals. Wearable BP entries were excluded from primary accuracy testing because audit confirmed they reflected static external cuff imports or uncalibrated overnight estimates rather than contemporaneous sensor measurements.

Results: Stationary plantar SBP and DBP biases were both −0.01 mmHg, with SDDs of 1.09 mmHg (95% LoA: −2.15 to +2.13 mmHg; CCC = 0.9890) and 0.75 mmHg (95% LoA: −1.48 to +1.45 mmHg; CCC = 0.9932), respectively, with 93.8% of SBP and 99.6% of DBP readings falling within ±2.0 mmHg of manual auscultation. Stationary plantar HR bias was +0.04 bpm (MAE = 0.34 bpm), whereas stationary OURA and WHOOP HR MAEs were 8.50 and 13.85 bpm. During treadmill exercise, reference HR surged by +60.38 bpm at minute 3 (145.51 bpm), whereas OURA and WHOOP lagged at 134.04 bpm (MD = −11.47 bpm) and 135.23 bpm (MD = −10.28 bpm). Across minutes 3–30, overall exercise MAE was 8.43 bpm (95% CI: 8.27–8.59) for OURA and 7.66 bpm (95% CI: 7.50–7.81) for WHOOP. During late exercise (minutes 12–30), cohort mean signed errors converged near zero (+0.81 bpm for OURA; +0.08 bpm for WHOOP), yet individual MAEs remained persistently elevated at 8.37 and 7.56 bpm, with 32.6% of OURA and 24.4% of WHOOP readings exceeding ±10 bpm error.

Conclusions: The Deep Health® plantar platform achieved sub-millimeter-of-mercury agreement with manual auscultation during quiet stance within the normotensive-to-prehypertensive range studied. Conversely, consumer upper-limb wearables exhibited severe initial algorithmic lag during rapid exertion and substantial participant-level error dispersion during sustained running that was masked by near-zero group mean bias. Furthermore, neither ring nor wrist PPG platforms possess the physical counter-bearing or hydrostatic transduction architecture required for instantaneous, uncalibrated blood pressure measurement.

Verbatim from DataCite (opens in a new tab) · Licence: https://creativecommons.org/licenses/by/4.0/legalcode

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Heart rateBlood pressure

Signals

Keywords

Consumer Wearable ValidationHeart RateExercise LagOuraWHOOPTreadmillBland AltmanPlantar BP

How it works

How Method works: Setup → Method → TargetSetup: Signals (ppg, bp, hr); Form factor (ring, wrist, standing plantar platform). Method: Method. Target: Heart rate; Blood pressure.SetupSignals: ppg, bp, hrSignalsppg, bp, hrForm factor: ring, wrist, standing plantar platformForm factorring, wrist, standing plantar platformMethodMethodTargetHeart rateHeart rateBlood pressureBlood pressure

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Weng, K., & Wei, E. (2026). Hemodynamic Fidelity Across Anatomical Acquisition Sites: Stationary Blood Pressure Concordance and Dynamic Treadmill Heart Rate Tracking of a Plantar Multi-Sensor Platform Versus Finger and Wrist Photoplethysmography in 483 Adults. Journal of Human Science & Technology 1 Article 7 , deposited on Zenodo. https://doi.org/10.5281/zenodo.24176147
Weng, Kai and Ethan Wei. 2026. "Hemodynamic Fidelity Across Anatomical Acquisition Sites: Stationary Blood Pressure Concordance and Dynamic Treadmill Heart Rate Tracking of a Plantar Multi-Sensor Platform Versus Finger and Wrist Photoplethysmography in 483 Adults." Journal of Human Science & Technology 1 Article 7 , deposited on Zenodo. https://doi.org/10.5281/zenodo.24176147.
Weng, K. and Wei, E. (2026) 'Hemodynamic Fidelity Across Anatomical Acquisition Sites: Stationary Blood Pressure Concordance and Dynamic Treadmill Heart Rate Tracking of a Plantar Multi-Sensor Platform Versus Finger and Wrist Photoplethysmography in 483 Adults', Journal of Human Science & Technology 1 Article 7 , deposited on Zenodo. doi: 10.5281/zenodo.24176147.
Weng, Kai, and Ethan Wei "Hemodynamic Fidelity Across Anatomical Acquisition Sites: Stationary Blood Pressure Concordance and Dynamic Treadmill Heart Rate Tracking of a Plantar Multi-Sensor Platform Versus Finger and Wrist Photoplethysmography in 483 Adults." Journal of Human Science & Technology 1 Article 7 , deposited on Zenodo, 2026. https://doi.org/10.5281/zenodo.24176147.
K. Weng and E. Wei, "Hemodynamic Fidelity Across Anatomical Acquisition Sites: Stationary Blood Pressure Concordance and Dynamic Treadmill Heart Rate Tracking of a Plantar Multi-Sensor Platform Versus Finger and Wrist Photoplethysmography in 483 Adults," Journal of Human Science & Technology 1 Article 7 , deposited on Zenodo, 2026, doi: 10.5281/zenodo.24176147.
@article{weng2026hemodynamic,
  title         = {{Hemodynamic Fidelity Across Anatomical Acquisition Sites: Stationary Blood Pressure Concordance and Dynamic Treadmill Heart Rate Tracking of a Plantar Multi-Sensor Platform Versus Finger and Wrist Photoplethysmography in 483 Adults}},
  author        = {Weng, Kai and Wei, Ethan},
  year          = {2026},
  journal       = {Journal of Human Science \& Technology 1 Article 7 , deposited on Zenodo},
  doi           = {10.5281/zenodo.24176147}
}

Added to the ChatPPG research hub