Re-implements the published evaluation of the only public wristband dataset that combines induced stress with structured exercise (36 participants), then repeats it with participants held out. The re-implementation did not match all published accuracies, held-out evaluation lowered exercise-recognition balanced accuracy by 0.05, and elapsed time alone separated stress from rest above chance. A physiology-only stress detector flagged 96% of exercise-session windows, which matters for automated insulin delivery systems that react to detected stress.

Abstract

Psychological stress tends to raise blood glucose and moderate exercise to lower it, so automated insulin delivery in type 1 diabetes could use wrist-worn stress detection that does not mistake exercise for stress. The only public wristband dataset known to us that combines induced stress with structured exercise (36 participants) reports accuracies of 0.84–0.93, but its evaluation did not keep participants apart, and each class was recorded in a separate session. Under a pre-registered plan, we re-implemented the published evaluation and repeated it on held-out participants, tested whether elapsed time and motion alone separated the classes, and counted stress-detector alarms during exercise. Our re-implementation did not match all published accuracies, held-out evaluation lowered exercise-recognition balanced accuracy by 0.05, and elapsed time alone separated stress from rest above chance. A physiology-only stress detector flagged 96% of exercise-session windows, including 80% of seated windows before exercise began (post hoc). In exploratory analyses, a detector trained with exercise examples rarely flagged exercise within the dataset, although motion features alone did almost as well (post hoc), and it missed a social stress test in an external dataset. Stress detectors for insulin delivery need validation on independent recordings combining strong stress with exercise.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Stress

Keywords

Stress DetectionExercise ConfoundLeakageParticipant SplitPre RegisteredReplicationAutomated Insulin DeliveryType 1 Diabetes

Datasets used

How it works

How Method works: Setup → Method → TargetSetup: Signals (eda, bvp, acc, temp, hr). Method: Method. Target: Stress.SetupSignals: eda, bvp, acc, temp, hrSignalseda, bvp, acc, temp, hrMethodMethodTargetStressStress

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Owida, H. A., Alsarhan, A., Banat, M., Al-Fraihat, D., & Algarni, A. (2026). Revealing Misclassification of Exercise Sessions in Wearable Stress Detection for Automated Insulin Delivery. Sensors , 2026, 26(22), 7340. https://doi.org/10.3390/s26227340
Owida, Hamza Abu, Ayoub Alsarhan, Mohannad Banat, Dimah Al-Fraihat, and Abdulmohsen Algarni. 2026. "Revealing Misclassification of Exercise Sessions in Wearable Stress Detection for Automated Insulin Delivery." Sensors , 2026 26 (22): 7340. https://doi.org/10.3390/s26227340.
Owida, H. A., Alsarhan, A., Banat, M., Al-Fraihat, D. and Algarni, A. (2026) 'Revealing Misclassification of Exercise Sessions in Wearable Stress Detection for Automated Insulin Delivery', Sensors , 2026, 26(22), p. 7340. doi: 10.3390/s26227340.
Owida, Hamza Abu, et al. "Revealing Misclassification of Exercise Sessions in Wearable Stress Detection for Automated Insulin Delivery." Sensors , 2026, vol. 26, no. 22, 2026, p. 7340. https://doi.org/10.3390/s26227340.
H. A. Owida, A. Alsarhan, M. Banat, D. Al-Fraihat, and A. Algarni, "Revealing Misclassification of Exercise Sessions in Wearable Stress Detection for Automated Insulin Delivery," Sensors , 2026, vol. 26, no. 22, p. 7340, 2026, doi: 10.3390/s26227340.
@article{owida2026revealing,
  title         = {{Revealing Misclassification of Exercise Sessions in Wearable Stress Detection for Automated Insulin Delivery}},
  author        = {Owida, Hamza Abu and Alsarhan, Ayoub and Banat, Mohannad and Al-Fraihat, Dimah and Algarni, Abdulmohsen},
  year          = {2026},
  journal       = {Sensors , 2026},
  volume        = {26},
  number        = {22},
  pages         = {7340},
  publisher     = {MDPI},
  doi           = {10.3390/s26227340}
}

Added to the ChatPPG research hub