Dataset

Finger-contact ECG + dual-wavelength (660/940 nm) PPG, rest + post-exercise recovery (n=148, 444 records)

This dataset has synchronized single-lead ECG and dual-wavelength PPG (660 and 940 nm) from 148 healthy subjects, recorded with a handheld finger-contact prototype. Each subject gave three seated records: one at rest, one after light treadmill running and one after moderate running, for 444 records in total.

Published
Data, 2026
Cohort
148 healthy subjects, 444 records
Device
handheld card-type finger-contact prototype
License
CC BY 4.0
Protocol

seated rest, recovery after light and after moderate treadmill running

At a glance
Type
Dataset
Host
Not reported
Access
Not reported
Subjects
148
Signals
PPGECG
PPG sites
Not reported
Setting
In the wild, Lab
Wrist
No
Raw waveforms
Yes
Tasks
Heart rate estimationMotion SQI
Updated
Nov 13, 2026

Original description

Electrocardiogram (ECG) and photoplethysmogram (PPG) signals are widely used noninvasive methods for assessing cardiovascular activity and provide complementary information about the cardiac cycle. ECG records cardiac electrical activity, whereas PPG records optically detected blood-volume changes in peripheral tissue. This paper describes a synchronized ECG-PPG dataset collected from 148 apparently healthy subjects under a controlled seated protocol at rest and during post-exercise recovery after two treadmill-running conditions. Signals were acquired using a custom card-type handheld finger-contact prototype that records single-lead ECG and dual-wavelength PPG at 660 nm and 940 nm concurrently. The dataset contains 444 condition-specific records, with each subject contributing one seated resting record, one seated recovery record after light treadmill running, and one seated recovery record after moderate treadmill running. Both raw ADC-count signals and preprocessed signals are provided, and the accompanying software and example code are publicly available. The dataset is intended for research on synchronized ECG-PPG signal analysis, waveform-quality assessment, controlled post-exercise recovery physiology, and exploratory PPG-to-ECG reconstruction under controlled conditions. It should not be interpreted as a free-living wearable dataset or as clinical diagnostic ECG ground truth without external validation.

Verbatim fromthe publisher's DOI record· Publisher licence: https://creativecommons.org/licenses/by/4.0/

Finger-contact ECG + dual-wavelength (660/940 nm) PPG, rest + post-exercise recovery (n=148, 444 records): ChatPPG research summary card

Key numbers

148
Subjects
2
Reference labels
ECG, HR

How it works

How Finger-contact ECG + dual-wavelength (660/940 nm) PPG, rest + post-exercise recovery (n=148, 444 records) works: Devices & body sites → Signals recorded → TasksSignals recorded: Finger-contact ECG + dual-wavelength (660/940 nm) PPG, rest + post-exercise recovery (n=148, 444 records), 148 subjects, signals PPG, ECG. Tasks: Heart rate; Signal quality.Signals recordedFinger-contact ECG +…148 subjectsPPGECGTasksHeart rateHeart rateSignal qualitySignal quality

No model in the hub reports results on this dataset yet.

Reference labels
ecg, hr

Cite this dataset

Cite this dataset with the fields recorded here. Check it against the publisher before submitting.

Finger-contact ECG + dual-wavelength (660/940 nm) PPG, rest + post-exercise recovery (n=148, 444 records) [Data set]. (n.d.). https://doi.org/10.3390/data11070155
@misc{fingercontactecgfingercontact,
  title         = {{Finger-contact ECG + dual-wavelength (660/940 nm) PPG, rest + post-exercise recovery (n=148, 444 records)}},
  doi           = {10.3390/data11070155}
}

Cite the ChatPPG record

Cite the dated snapshot 2026-10 for a fixed, reproducible version. Please also cite the original publications listed above.

APA

ChatPPG. (2026). Finger-contact ECG + dual-wavelength (660/940 nm) PPG, rest + post-exercise recovery (n=148, 444 records): dataset record (Version 2026-10) [Data set]. ChatPPG Research Hub. https://chatppg.com/research/datasets/finger-contact-ecg-dual-wavelength-ppg-post-exercise

BibTeX
@misc{chatppg_dataset_finger_contact_ecg_dual_wavelength_ppg_post_exercise,
  author       = {{ChatPPG}},
  title        = {{Finger-contact ECG + dual-wavelength (660/940 nm) PPG, rest + post-exercise recovery (n=148, 444 records): dataset record}},
  year         = {2026},
  month        = nov,
  version      = {2026-10},
  howpublished = {\url{https://chatppg.com/research/datasets/finger-contact-ecg-dual-wavelength-ppg-post-exercise}},
  note         = {ChatPPG Research Hub, Snapshot 2026-10, https://chatppg.com/research/snapshots/2026-10}
}
CITATION.cff
cff-version: 1.2.0
message: "If you use this resource, please cite it as below."
type: dataset
title: "Finger-contact ECG + dual-wavelength (660/940 nm) PPG, rest + post-exercise recovery (n=148, 444 records): dataset record"
authors:
  - name: "ChatPPG"
url: "https://chatppg.com/research/datasets/finger-contact-ecg-dual-wavelength-ppg-post-exercise"
repository-artifact: "https://chatppg.com/research/snapshots/2026-10"
version: "2026-10"
date-released: "2026-11-13"

History

  1. Record updated