Paperdoi:10.1109/access.2026.3730539
Interpretable Reliability Control for Wearable PPG Heart Rate Estimation
IEEE Access
TL;DR
Interpretable reliability / selective-reporting control for wearable PPG heart-rate estimation. Adjacent to CITRUS-style accept/hold/reject policies.
- Form factor: wrist
Abstract
Wearable photoplethysmography (PPG) can return a plausible heart rate (HR) after motion or poor optical coupling has made the measurement unreliable. We treat HR reporting as a reliability-control problem and introduce an interpretable signal quality index (SQI) layer that reports coverage and residual error. On PPG-DaLiA, electrocardiography (ECG) supplied offline targets only; inference used PPG and accelerometer (ACC) features. The Cascade Veto defined three reliability states, while a HistGradientBoosting (HGB) regressor ranked continuous error risk. In 15-fold leave-one-subject-out testing, random forest classification attained a mean macro-F1 of 0.8995. Its static High-only policy achieved 1.479 bpm mean absolute error (MAE) with subject-adaptive coverage averaging 19.95%. Strict and permissive label configurations shifted High-only coverage to 16.54% and 22.79%, with MAEs of 1.257 and 1.666 bpm. At matched 10%, 20%, and 40% coverage, HGB achieved 1.006, 1.428, and 2.699 bpm, compared with 5.464, 5.605, and 7.043 bpm for ACC-energy ranking. Within activities at 20% coverage, HGB achieved 3.957 bpm versus 11.537 bpm for ACC and 16.714 bpm for random selection. Accepted windows clustered over time: the median subject-level maximum HGB blackout was 1356, 684, and 312 s. On an independent device, HGB trained on PPG-DaLiA reduced MAE by 61.2% relative to the full-coverage baseline at 10% coverage without external refitting. HGB provided the lower fixed-coverage MAE, whereas Cascade retained interpretable release states. The matched controls indicate that PPG/ACC features contain reliability information across subjects, activities, and the independent device.
Verbatim from Semantic Scholar (opens in a new tab) · Abstract via Semantic Scholar; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
APA
Liang, Y., Zhang, S., & Yang, Z. (2026). Interpretable Reliability Control for Wearable PPG Heart Rate Estimation. IEEE Access. https://doi.org/10.1109/access.2026.3730539
BibTeX
@article{liang2026interpretable,
title = {{Interpretable Reliability Control for Wearable PPG Heart Rate Estimation}},
author = {Liang, Yekun and Zhang, Shiwei and Yang, Zhou},
year = {2026},
journal = {IEEE Access},
doi = {10.1109/access.2026.3730539}
}Built from the hub record. Check it against the publisher before submitting.