Paper

Foundation Model Artificial Intelligence for Electrocardiogram Detection of Rheumatic Mitral Stenosis

Raghav Sriram, Ivan Nenadic, Zak Loring, Marat Fudim, Anthony Mazella, Anil K. Gehi +1 more
openRxiv2026ECGCC BY 4.0 (preprint)
PreprintCatalog paper date: Oct 13, 2026Added to atlas: Oct 14, 2026Source
Citations0Crossref referencesChecked Oct 16, 2026
GitHub stars—Not available
HF downloads—Not available

Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.

This study tested whether an ECG foundation model can detect rheumatic mitral stenosis from a limited set of indirectly labelled ECGs. The model was fine-tuned on 804 positive ECGs per fold and validated externally on clinical and wearable lead setups. AUROC was 0.89, 0.87 and 0.87 in held-out testing for 12, 6 and 1 leads, and 0.82, 0.80 and 0.77 in external validation.

  • Signals: ECG
  • Result: Internal AUROCs were 0.89, 0.87, and 0.87, for 12-Lead, 6-Lead, and 1-Lead respectively.
  • Result: External AUROCs were 0.82, 0.80, and 0.77.
At a glance
Venue
openRxiv
Published
2026
arXiv
Not reported
PMID
Not reported
Signals
ECG
Form factor
Clinical
Subjects
Not reported
Code
Not reported
Added
Oct 14, 2026

Abstract

Background: Rheumatic mitral stenosis (RMS) disproportionately affects low-resource settings where echocardiography is limited. We evaluated foundation model (FM) feasibility for RMS detection using limited, indirectly labeled ECGs. Methods: An ECG-FM was fine-tuned using 804 RMS-positive ECGs per fold and externally validated across clinical and wearable lead configurations. Results: Internal AUROCs were 0.89, 0.87, and 0.87, for 12-Lead, 6-Lead, and 1-Lead respectively. External AUROCs were 0.82, 0.80, and 0.77. Performance remained comparable across demographic subgroups. Conclusions: FM fine-tuning enables RMS detection using limited ICD-derived labels, supporting further evaluation of reduced-lead ECG screening and echocardiography triage in resource-constrained settings.

Verbatim fromthe publisher's DOI record· Publisher licence: http://creativecommons.org/licenses/by/4.0/

Foundation Model Artificial Intelligence for Electrocardiogram Detection of Rheumatic Mitral Stenosis: ChatPPG research summary card

Key results

0.89
AUROC
AUROC was 0.89, 0.87 and 0.87 in held-out testing for 12, 6 and 1 leads, and 0.82, 0.80 and 0.77 in external validation.

How it works

How Method works: Setup → Method → ResultSetup: Signals (ECG). Method: Method. Result: Result (Internal AUROCs were 0.89, 0.87, and 0.87, for 12-Lead, 6-Lead, and 1-Lead respectively.); Result (External AUROCs were 0.82, 0.80, and 0.77.).SetupSignals: ECGSignalsECGMethodMethodResultResult: Internal AUROCs were 0.89, 0.87, and 0.87, for 12-Lead, 6-Lead, and 1-Lead respectively.ResultInternal AUROCs were 0.89, 0.87, and…Result: External AUROCs were 0.82, 0.80, and 0.77.ResultExternal AUROCs were 0.82, 0.80, and…

Cite

@article{rmsecgfmreducedleadrheum2026,
  title = {{Foundation Model Artificial Intelligence for Electrocardiogram Detection of Rheumatic Mitral Stenosis}},
  author = {Raghav Sriram and Ivan Nenadic and Zak Loring and Marat Fudim and Anthony Mazella and Anil K. Gehi and Venkatesh L. Murthy},
  year = {2026},
  journal = {openRxiv},
  doi = {10.64898/2026.10.12.26365300}
}

History

  1. Added to the ChatPPG research hub