PaperarXiv:2611.14849

Generalize Then Personalize: Wearable-Based Heart Rate Forecasting Under Scarce Ruck-March Data

PreprintDated Nov 10, 2026Added Nov 13, 2026

  • MR
  • RM
  • JR
  • DC

Authors: Muntaqim Ahmed Raju, Ruizhe Ma, John W. Ramsay, David J. Cornell

IEEE BIBM 2026 (arXiv preprint)

TL;DR

HR forecasting (30/60 s ahead) during loaded ruck marches by 8 US Army medics. Population pretraining then per-person fine-tuning (PPFT) beat population-only and personal-from-scratch models. A naive persistence baseline still had the best 30 s MAE.

Abstract

Heart rate (HR) forecasting may provide advance information about near-future cardiovascular response, potentially supporting physiological monitoring and workload-management decisions during ruck marching. However, robust model development is constrained by the difficulty of collecting large-scale ruck-march datasets, creating a scarce-data problem in which models must generalize across participants while adapting to individuals from limited personal data. To address this problem, we benchmark population-only training (POT), personalized-from-scratch training (PFST), and population-pretrained fine-tuning (PPFT) for HR forecasting during loaded ruck marching using data from eight active-duty U.S. Army medics across thirteen sessions. LSTM, Attention-LSTM, and CNN-LSTM backbones were evaluated against a persistence baseline at 30 s and 60 s horizons. Across all neural architectures and horizons, PPFT yielded lower mean MAE, RMSE, and endpoint MAE than both POT and PFST. Participant-level paired analysis after averaging across three training seeds showed that, relative to PFST, PPFT reduced trajectory MAE by 2.22-4.30 bpm and endpoint MAE by 1.24-2.88 bpm. All six trajectory-MAE comparisons remained significant after Holm adjustment (p_adj = 0.0469), while four of six endpoint-MAE comparisons remained significant after adjustment. At 30 s, persistence achieved the lowest MAE (3.555 ± 1.274 bpm), while CNN-LSTM PPFT achieved the lowest RMSE (4.669 ± 1.916 bpm); LSTM PPFT achieved the lowest endpoint MAE (5.093 ± 2.365 bpm). At 60 s, Attention-LSTM PPFT achieved the lowest MAE (5.573 ± 1.939 bpm) and RMSE (7.134 ± 2.260 bpm), while CNN-LSTM PPFT achieved the lowest endpoint MAE (7.553 ± 2.357 bpm). These results suggest that population pretraining followed by participant-specific fine-tuning may provide a practical strategy for scarce-data wearable HR forecasting.

Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Heart rateMental workload

Signals

Keywords

MilitaryRuck MarchHR ForecastingPersonalizationFine TuningLstmCnn LstmScarce Data

How it works

How Method works: Setup → Method → TargetSetup: Signals (hr, accelerometer, gps). Method: Method (Convolutional network). Target: Heart rate; Mental workload.SetupSignals: hr, accelerometer, gpsSignalshr, accelerometer, gpsMethodMethodConvolutional networkTargetHeart rateHeart rateMental workloadMental workload

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Raju, M. A., Ma, R., Ramsay, J. W., & Cornell, D. J. (2026). Generalize Then Personalize: Wearable-Based Heart Rate Forecasting Under Scarce Ruck-March Data. IEEE BIBM 2026. https://arxiv.org/abs/2611.14849
Raju, Muntaqim Ahmed, Ruizhe Ma, John W. Ramsay, and David J. Cornell. 2026. "Generalize Then Personalize: Wearable-Based Heart Rate Forecasting Under Scarce Ruck-March Data." IEEE BIBM 2026. https://arxiv.org/abs/2611.14849.
Raju, M. A., Ma, R., Ramsay, J. W. and Cornell, D. J. (2026) 'Generalize Then Personalize: Wearable-Based Heart Rate Forecasting Under Scarce Ruck-March Data', IEEE BIBM 2026. Available at: https://arxiv.org/abs/2611.14849
Raju, Muntaqim Ahmed, et al. "Generalize Then Personalize: Wearable-Based Heart Rate Forecasting Under Scarce Ruck-March Data." IEEE BIBM 2026, 2026. https://arxiv.org/abs/2611.14849.
M. A. Raju, R. Ma, J. W. Ramsay, and D. J. Cornell, "Generalize Then Personalize: Wearable-Based Heart Rate Forecasting Under Scarce Ruck-March Data," IEEE BIBM 2026, 2026, [Online]. Available: https://arxiv.org/abs/2611.14849.
@article{raju2026generalize,
  title         = {{Generalize Then Personalize: Wearable-Based Heart Rate Forecasting Under Scarce Ruck-March Data}},
  author        = {Raju, Muntaqim Ahmed and Ma, Ruizhe and Ramsay, John W. and Cornell, David J.},
  year          = {2026},
  journal       = {IEEE BIBM 2026},
  eprint        = {2611.14849},
  archivePrefix = {arXiv}
}

Source metadata: 2026

Record updated Nov 13, 2026

Added to the ChatPPG research hub