Uncertainty-aware fourier-encoded attentive Bi-GRU for non-invasive blood glucose estimation from multimodal PPG and GSR signals

Venue listedDated Oct 28, 2026Added Nov 12, 2026

  • AP
  • HJ
  • MA

Authors: Allam Jaya Prakash, Herbert F. Jelinek, Mohamed Atef

Frontiers in Medical Technology 8:1979468, 2026

First page or project page of “Uncertainty-aware fourier-encoded attentive Bi-GRU for non-invasive blood glucose estimation from multimodal PPG and GSR signals” (opens in a new tab)

Allam Jaya Prakash et al., "Uncertainty-aware fourier-encoded attentive Bi-GRU for non-invasive blood glucose estimation from multimodal PPG and GSR signals", doi:10.3389/fmedt.2026.1979468, CC BY 4.0

TL;DR

PPG+GSR Bi-GRU glucose regressor on PhysioCGM (10 adults with T1D, CGM reference). Random 80/20 split: MAE 3.09 mg/dL, 96.3% Clarke zone A; leave-one-subject-out: MAE 16.75 mg/dL with weak hypoglycaemia agreement. The gap is the finding.

Abstract

Noninvasive estimation of glucose from wearable physiological signals remains challenging because sensor–glucose relationships vary across individuals and point estimates do not convey reliability. This article presents an uncertainty-aware regression framework that combines photoplethysmography and galvanic skin response. Synchronized signal segments are transformed using deterministic harmonic Fourier features and processed by a dense projection, a bidirectional gated recurrent unit with additive attention, and a multilayer regressor. Training uses a composite objective comprising mean absolute error, input-gradient smoothness, and a soft constraint on standardized outputs, while Monte Carlo dropout estimates model uncertainty during inference. The framework was evaluated on PhysioCGM recordings from 10 adults with type 1 diabetes, with continuous glucose monitor measurements used as reference values. A random sample-wise 80/20 split yielded a mean absolute error of 3.09 mg/dL, a root mean-square error of 4.72 mg/dL, and a coefficient of determination of 0.960; 96.3% and 99.1% of predictions were located in Clarke Error Grid Zone A and Zones A+B, respectively. In contrast, ten-fold leave-one-subject-out evaluation yielded a mean absolute error of 16.75 mg/dL with a between-fold standard deviation of 0.44 mg/dL and substantially weaker agreement in the hypoglycemic range. These findings indicate strong within-cohort interpolation but limited generalization to unseen individuals and underrepresented glycemic extremes. Larger participant-disjoint studies and calibrated uncertainty estimates are required before clinical or wearable deployment.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Glucose

Signals

Keywords

GlucoseNon Invasive GlucoseGSRBi GRUAttentionMonte Carlo DropoutUncertaintyLOSO

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG, EDA). Method: Method (Transformer). Target: Glucose.SetupSignals: PPG, EDASignalsPPG, EDAMethod×NMethodTransformerTargetGlucoseGlucose

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Prakash, A. J., Jelinek, H. F., & Atef, M. (2026). Uncertainty-aware fourier-encoded attentive Bi-GRU for non-invasive blood glucose estimation from multimodal PPG and GSR signals. Frontiers in Medical Technology , 2026, 8, 1979468. https://doi.org/10.3389/fmedt.2026.1979468
Prakash, Allam Jaya, Herbert F. Jelinek, and Mohamed Atef. 2026. "Uncertainty-aware fourier-encoded attentive Bi-GRU for non-invasive blood glucose estimation from multimodal PPG and GSR signals." Frontiers in Medical Technology , 2026 8: 1979468. https://doi.org/10.3389/fmedt.2026.1979468.
Prakash, A. J., Jelinek, H. F. and Atef, M. (2026) 'Uncertainty-aware fourier-encoded attentive Bi-GRU for non-invasive blood glucose estimation from multimodal PPG and GSR signals', Frontiers in Medical Technology , 2026, 8, p. 1979468. doi: 10.3389/fmedt.2026.1979468.
Prakash, Allam Jaya, et al. "Uncertainty-aware fourier-encoded attentive Bi-GRU for non-invasive blood glucose estimation from multimodal PPG and GSR signals." Frontiers in Medical Technology , 2026, vol. 8, 2026, p. 1979468. https://doi.org/10.3389/fmedt.2026.1979468.
A. J. Prakash, H. F. Jelinek, and M. Atef, "Uncertainty-aware fourier-encoded attentive Bi-GRU for non-invasive blood glucose estimation from multimodal PPG and GSR signals," Frontiers in Medical Technology , 2026, vol. 8, p. 1979468, 2026, doi: 10.3389/fmedt.2026.1979468.
@article{prakash2026uncertaintyaware,
  title         = {{Uncertainty-aware fourier-encoded attentive Bi-GRU for non-invasive blood glucose estimation from multimodal PPG and GSR signals}},
  author        = {Prakash, Allam Jaya and Jelinek, Herbert F. and Atef, Mohamed},
  year          = {2026},
  journal       = {Frontiers in Medical Technology , 2026},
  volume        = {8},
  pages         = {1979468},
  doi           = {10.3389/fmedt.2026.1979468}
}

Added to the ChatPPG research hub