PaperarXiv:2608.01820
Reassessing the Feasibility of PPG-Based Non-Invasive Blood Glucose Level Estimation
arXiv preprint
TL;DR
This paper re-tests five published methods for estimating blood glucose from PPG with a reproducible pipeline and three increasingly strict ways of splitting the data. The models looked competitive when windows were split at random but collapsed once the same person could not appear in both training and test sets, with R² near zero or negative, no better than predicting the mean. Over 90% of predictions still landed in the Clarke Error Grid A+B zones, including the mean baseline, which shows that metric alone is misleading.
- Result: near-zero or negative R² under participant-aware splits
- Result: >90% Clarke A+B even for the mean baseline
Abstract
Non-invasive blood glucose level (BGL) estimation from photoplethysmography (PPG) holds great promise for wearable health monitoring, but results across studies are hard to compare due to inconsistent datasets, data leakage, and non-standardized evaluation metrics. We present the first reproducible, extensible evaluation pipeline and use it to reassess five representative PPG-based BGL methods on published datasets under three increasingly strict data-split protocols: random window-level, participant-aware, and leave-some-participants-out (LSPO). Models appeared competitive under random splitting but collapsed under participant-aware and LSPO evaluation, with nearly all yielding near-zero or negative R^2 values comparable to a mean-prediction baseline. Critically, across every model and split, over 90% of predictions fell within clinically acceptable zones (Clarke Error Grid A+B), including the baseline. This reveals a fundamental disconnect: clinical zone metrics systematically conceal model failure in this domain. Our findings demonstrate that random train-test splits substantially overestimate the generalization of PPG-based BGL models due to sample-level data leakage, and that robust ML evaluation must precede clinical validation to meaningfully assess real-world utility.
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Signals
How it works
- Methods re-tested
- 5 published PPG glucose models
Cite this paper
Ramesh, S., Neufeld, M., Küttner, M., Röddiger, T., & Beigl, M. (2026). Reassessing the Feasibility of PPG-Based Non-Invasive Blood Glucose Level Estimation. arXiv preprint. https://arxiv.org/abs/2608.01820
Ramesh, Supraja, Markus Neufeld, Michael Küttner, Tobias Röddiger, and Michael Beigl. 2026. "Reassessing the Feasibility of PPG-Based Non-Invasive Blood Glucose Level Estimation." arXiv preprint. https://arxiv.org/abs/2608.01820.
Ramesh, S., Neufeld, M., Küttner, M., Röddiger, T. and Beigl, M. (2026) 'Reassessing the Feasibility of PPG-Based Non-Invasive Blood Glucose Level Estimation', arXiv preprint. Available at: https://arxiv.org/abs/2608.01820
Ramesh, Supraja, et al. "Reassessing the Feasibility of PPG-Based Non-Invasive Blood Glucose Level Estimation." arXiv preprint, 2026. https://arxiv.org/abs/2608.01820.
S. Ramesh, M. Neufeld, M. Küttner, T. Röddiger, and M. Beigl, "Reassessing the Feasibility of PPG-Based Non-Invasive Blood Glucose Level Estimation," arXiv preprint, 2026, [Online]. Available: https://arxiv.org/abs/2608.01820.
@misc{ramesh2026reassessing,
title = {{Reassessing the Feasibility of PPG-Based Non-Invasive Blood Glucose Level Estimation}},
author = {Ramesh, Supraja and Neufeld, Markus and Küttner, Michael and Röddiger, Tobias and Beigl, Michael},
year = {2026},
howpublished = {arXiv preprint},
eprint = {2608.01820},
archivePrefix = {arXiv}
}