Paperdoi:10.64898/2026.08.01.26359472

Skin-tone-robust topological signal processing (Melanin Absorption Invariance) for optical pulse measurement (Oladunni & Adewumi, medRxiv 2026)

Preprint2026Added Nov 5, 2026

  • TO
  • FA

Authors: Timothy Oladunni, Farouk Ganiyu Adewumi

medRxiv preprint, 2026-08-03

First page or project page of “Skin-tone-robust topological signal processing (Melanin Absorption Invariance) for optical pulse measurement (Oladunni & Adewumi, medRxiv 2026)” (opens in a new tab)

Timothy Oladunni et al., "Skin-Tone-Robust Topological Signal Processing: A Framework for Bias-Reducing Optical Measurement Systems", doi:10.64898/2026.08.01.26359472, CC BY-NC 4.0

TL;DR

Proposes a label-free 'Melanin Absorption Invariance' framework that keeps topological (attractor) rather than geometric signal structure, with two theorems bounding bias under Z-normalisation and SNR-adaptive correction. Validated on MMPD (smartphone camera rPPG; 656 recordings, 33 subjects, Fitzpatrick III–VI, 4 lighting, 5 motion types). Claims 2× greater bias reduction than geometric-only methods (abstract truncated before further comparisons).

  • Form factor: camera

Abstract

Photoplethysmography (PPG, optical measurement of cardiac blood volume changes) is the foundation of wearable cardiac monitoring, but systematically fails on dark skin due to melanin absorption. We present the Melanin Absorption Invariance (MAI) framework: a label-free method that substantially reduces cross-skin-tone bias in cardiac feature extraction by preserving topological rather than geometric signal structure. We prove two theorems: Theorem 1 bounds attractor bias to

under Z-normalization; Theorem 2 reduces residual bias to

via SNR-adaptive correction. Empirical validation confirms these theoretical predictions on real dark-skin PPG signals.

Comprehensive empirical validation on the complete MMPD dataset (Fitzpatrick III–VI, n = 656 recordings, 33 subjects, spanning all 4 lighting conditions and 5 motion types, Samsung Galaxy mobile phone) demonstrates MAI generalization across real-world deployment conditions. Results show substantial attractor bias reduction across all skin tone groups, with largest effects for Fitzpatrick IV and VI populations most affected by current systems. Direct empirical comparison shows MAI achieves 2× greater bias reduction than geometric-only methods and 1.7× greater than standard Z-normalization alone, validating that topological analysis is essential for skin-tone-robust measurement. This work demonstrates a theoretically grounded, label-free, skin-tone-robust cardiac monitoring framework.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: http://creativecommons.org/licenses/by-nc/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Skin ToneFairnessMelaninTopological Data AnalysisAttractorMmpd

Datasets used

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG, rPPG); Form factor (camera). Method: Method.SetupSignals: PPG, rPPGSignalsPPG, rPPGForm factor: cameraForm factorcameraMethodMethod

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Oladunni, T., & Adewumi, F. G. (2026). Skin-tone-robust topological signal processing (Melanin Absorption Invariance) for optical pulse measurement (Oladunni & Adewumi, medRxiv 2026). medRxiv preprint. https://doi.org/10.64898/2026.08.01.26359472
Oladunni, Timothy and Farouk Ganiyu Adewumi. 2026. "Skin-tone-robust topological signal processing (Melanin Absorption Invariance) for optical pulse measurement (Oladunni & Adewumi, medRxiv 2026)." medRxiv preprint. https://doi.org/10.64898/2026.08.01.26359472.
Oladunni, T. and Adewumi, F. G. (2026) 'Skin-tone-robust topological signal processing (Melanin Absorption Invariance) for optical pulse measurement (Oladunni & Adewumi, medRxiv 2026)', medRxiv preprint. doi: 10.64898/2026.08.01.26359472.
Oladunni, Timothy, and Farouk Ganiyu Adewumi "Skin-tone-robust topological signal processing (Melanin Absorption Invariance) for optical pulse measurement (Oladunni & Adewumi, medRxiv 2026)." medRxiv preprint, 2026. https://doi.org/10.64898/2026.08.01.26359472.
T. Oladunni and F. G. Adewumi, "Skin-tone-robust topological signal processing (Melanin Absorption Invariance) for optical pulse measurement (Oladunni & Adewumi, medRxiv 2026)," medRxiv preprint, 2026, doi: 10.64898/2026.08.01.26359472.
@misc{oladunni2026skintonerobust,
  title         = {{Skin-tone-robust topological signal processing (Melanin Absorption Invariance) for optical pulse measurement (Oladunni \& Adewumi, medRxiv 2026)}},
  author        = {Oladunni, Timothy and Adewumi, Farouk Ganiyu},
  year          = {2026},
  howpublished  = {medRxiv preprint},
  doi           = {10.64898/2026.08.01.26359472}
}

Added to the ChatPPG research hub