Paperdoi:10.5281/zenodo.24451554

ecg-coding-agents: local and commercial coding agents computing QT, QTc, and HRV from PhysioNet ECG recordings (manuscript: Four Coding Agents Against Expert ECG Annotations: One Outscored Signal-Free Answers on HRV, Not Demonstrably on QT)

Venue listedDated Nov 22, 2026Added Nov 23, 2026

Zenodo software records 10.5281/zenodo.24432257 (v1.0.0, 2026-11-22) and 10.5281/zenodo.24451554 (v1.1.0, 2026-11-23); manuscript in preparation

TL;DR

Zenodo software (MIT) for a benchmark in which coding agents write and run Python in a network-free container to compute QT, QTc and frequency-domain HRV from PhysioNet ECG recordings, scored against expert annotations (QT Database and Fantasia) over 99 tasks with five runs per model. It compares three local models (Qwen2.5-Coder 7B and 3B, Llama-3.1-8B) and one hosted model with a fixed NeuroKit2 pipeline, constant-answer and RR-model baselines, and version 1.1.0 adds a preregistered confirmatory QT test on 31 held-out records.

Abstract

Harness, task set, expert-derived references, scoring, and aggregate results for a preregistered evaluation of language-model coding agents that write and run Python to measure QT, corrected QT, and frequency-domain heart-rate variability from PhysioNet recordings (QT Database, Fantasia, MIT-BIH Arrhythmia Database). Three locally run open-weight models (Qwen2.5-Coder-7B-Instruct, Qwen2.5-Coder-3B-Instruct, Llama-3.1-8B-Instruct) and one commercial model (DeepSeek-V4-flash) run 99 tasks five times each, with the agent's code executed in a network-free container; a library-only NeuroKit2 pipeline is the baseline, and an exploratory arm appends a reference of the installed library functions to the system prompt of the local models. Version 1.1.0 adds the post hoc checks (constant-answer and RR-model baselines, run-level QT agreement, provenance of answered numbers) and a preregistered confirmatory QT test on 31 held-out QT Database records (155 runs), with its plan, scripts, outputs, and transcripts. No PhysioNet data are included.

Verbatim from DataCite (opens in a new tab) · Licence: https://opensource.org/licenses/MIT

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Llm AgentsCoding AgentsBenchmarkPreregisteredQt IntervalQtcHRVNeurokit2

Datasets used

How it works

How Method works: Setup → Method → TargetSetup: Signals (ecg). Method: Method (Language-aligned).SetupSignals: ecgSignalsecgMethodMethodLanguage-aligned

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

ecg-coding-agents: local and commercial coding agents computing QT, QTc, and HRV from PhysioNet ECG recordings (manuscript: Four Coding Agents Against Expert ECG Annotations: One Outscored Signal-Free Answers on HRV, Not Demonstrably on QT). (2026). Zenodo software records 10.5281/zenodo.24432257 and 10.5281/zenodo.24451554. https://doi.org/10.5281/zenodo.24451554
@article{halimecgcodingag2026ecgcodingagents,
  title         = {{ecg-coding-agents: local and commercial coding agents computing QT, QTc, and HRV from PhysioNet ECG recordings (manuscript: Four Coding Agents Against Expert ECG Annotations: One Outscored Signal-Free Answers on HRV, Not Demonstrably on QT)}},
  year          = {2026},
  journal       = {Zenodo software records 10.5281/zenodo.24432257 and 10.5281/zenodo.24451554},
  doi           = {10.5281/zenodo.24451554}
}

Added to the ChatPPG research hub