Paperdoi:10.1038/s41598-021-86280-5

Characterization of laser speckle flowgraphy pulse waveform parameters for the evaluation of the optic nerve head and retinal circulation

Venue listed2021Added Oct 29, 2026

  • NE
  • AA
  • GT
  • AI
  • MM
  • J

Authors: Nobuko Enomoto, Akane Anraku, Goji Tomita, Aiko Iwase, … Makoto Araie (multicentre, Japan)

Scientific Reports 11:6847, 2021

TL;DR

Laser speckle flowgraphy is a clinical eye-imaging method that reads blood flow in the optic nerve head from laser speckle blur. In 111 eyes of 86 healthy adults, the shape of its pulse waveform (skew, flow acceleration and related indices) related to systemic factors and retinal vessel measures, which supports waveform features as markers of ocular circulation.

  • Form factor: other

Abstract

To characterize laser speckle flowgraphy (LSFG) pulse waveform parameters for ocular circulation evaluation, a multicenter, prospective, cross-sectional study was conducted in 111 eyes of 86 healthy Japanese individuals. Optic nerve head (ONH) tissue-area, vessel-area mean blur rate (MT and MV, respectively), and MT and MV pulse waveform parameters were obtained using LSFG and ONH structural parameters using planimetry. Multivariate linear mixed-effects modeled regression analysis identified factors contributing to MT- or MV-waveforms using age, gender, smoking history, body mass index, systolic and diastolic blood pressure, heart rate, intraocular pressure, axial length, disc, rim, and β-peripapillary atrophy areas, MT or MV, central retinal artery, and vein equivalents (CRAE and CRVE) as explanatory variables. MT- and MV-waveforms significantly correlated with one or more systemic factors, consistent with previous studies. Following confounding factor adjustment, MT-Skew significantly negatively correlated with β-PPA area ( P  = 0.026); MT- and MV-flow acceleration index positively correlated with CRAE, MT, and MV ( P  = 0.041–< 0.001), compatible with these parameters’ observed correlations to systemic factors. Significantly negative correlations of the blowout score and acceleration time index to CRAE partly conflicted with their correlations to systemic factors, and other waveform parameters showed little correlation to ocular factors. Thus, Skew and flow acceleration index assisted the in vivo ocular circulation characterization.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Speckle PlethysmographyLaser Speckle FlowgraphyOphthalmologyPulse WaveformMean Blur RateJapan

How it works

How Method works: Setup → Method → TargetSetup: Signals (LSFG); Wavelengths (laser (λ not in abstract)); Form factor (other). Method: Method.SetupSignals: LSFGSignalsLSFGWavelengths: laser (λ not in abstract)Wavelengthslaser (λ not in abstract)Form factor: otherForm factorotherMethodMethod
Wavelengths
laser (λ not in abstract)

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Characterization of laser speckle flowgraphy pulse waveform parameters for the evaluation of the optic nerve head and retinal circulation. (2021). Scientific Reports , 2021, 11, 6847. https://doi.org/10.1038/s41598-021-86280-5
@article{enomotolsfgpulse2021characterization,
  title         = {{Characterization of laser speckle flowgraphy pulse waveform parameters for the evaluation of the optic nerve head and retinal circulation}},
  year          = {2021},
  journal       = {Scientific Reports , 2021},
  volume        = {11},
  pages         = {6847},
  doi           = {10.1038/s41598-021-86280-5}
}

Added to the ChatPPG research hub