Paperdoi:10.1117/1.JBO.31.2.025002

Comparing multi- and single-exposure speckle contrast optical spectroscopy methods as estimators of blood flow in the diffuse regime

Venue listed2026Added Oct 29, 2026

  • SA
  • AE
  • AF

Authors: Sean Aleman, Arnold D. Estrada, Ashwin B. Parthasarathy (University of South Florida)

Journal of Biomedical Optics 31(02):1, 2026

TL;DR

A simulation study compared estimating blood flow from speckle contrast at a single camera exposure (as standard SCOS and SPG do) with fitting a curve over many exposures (multi-exposure speckle imaging). Multi-exposure kept errors under 1 % even when calibration and noise were off, while single-exposure methods could be off by up to 90 % and misjudge pulsatile flow by 22 % or more.

  • Form factor: lab

Abstract

SignificanceSpeckle contrast optical spectroscopy (SCOS) and speckle plethysmography (SPG) are increasingly used to measure deep tissue blood flow from tissues. However these methods derive flow from measurements at a single exposure duration, which could introduce errors due to inefficient choice of a single integration time, changes in speckle averaging factors (β), and noise.AimThe aims are to compare and evaluate the robustness of single- and multi-exposure speckle contrast methods in estimating blood flow changes under experimental conditions such as β mismatch, noise, and pulsatile flow.ApproachSpeckle visibility was simulated at 10,000 logarithmically spaced exposure durations (0.01 to 10 ms), incorporating ±5 to 15% noise, using a semi-infinite diffusion model at different physiologically relevant steady state and pulsatile flow rates. Speckle visibility was used to estimate blood flow changes using both the multi-exposure approach (non-linear fitting of the full curve) and conventional single exposure approach at 0.1, 1, and 5 ms durations (SCOS, SPG, and look-up-table), under different noise conditions and mismatches in β.ResultsMulti-exposure speckle imaging (MESI) maintained <1% mean error despite β mismatch or noise while maintaining ≤12% pulsatile-flow error at ±5% noise. Single-exposure methods showed errors up to 90% for β mismatch/noise and ≥22% pulsatile-flow errors.ConclusionsMESI outperformed single-exposure approaches in estimating blood flow changes by reducing β bias, minimizing noise sensitivity, and accurately tracking pulsatile dynamics.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Keywords

Speckle PlethysmographyExposure TimeBetaSimulationUsf

How it works

How Method works: Setup → Method → TargetSetup: Signals (SCOS, SPG, MESI); Wavelengths (n/a (simulation)); Form factor (lab). Method: Method.SetupSignals: SCOS, SPG, MESISignalsSCOS, SPG, MESIWavelengths: n/a (simulation)Wavelengthsn/a (simulation)Form factor: labForm factorlabMethodMethod
Wavelengths
n/a (simulation)

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Aleman, S., Estrada, A. D., & Parthasarathy, A. B. (2026). Comparing multi- and single-exposure speckle contrast optical spectroscopy methods as estimators of blood flow in the diffuse regime. Journal of Biomedical Optics , 2026, 31(02), 1. https://doi.org/10.1117/1.JBO.31.2.025002
Aleman, Sean, Arnold D. Estrada, and Ashwin B. Parthasarathy. 2026. "Comparing multi- and single-exposure speckle contrast optical spectroscopy methods as estimators of blood flow in the diffuse regime." Journal of Biomedical Optics , 2026 31 (02): 1. https://doi.org/10.1117/1.JBO.31.2.025002.
Aleman, S., Estrada, A. D. and Parthasarathy, A. B. (2026) 'Comparing multi- and single-exposure speckle contrast optical spectroscopy methods as estimators of blood flow in the diffuse regime', Journal of Biomedical Optics , 2026, 31(02), p. 1. doi: 10.1117/1.JBO.31.2.025002.
Aleman, Sean, et al. "Comparing multi- and single-exposure speckle contrast optical spectroscopy methods as estimators of blood flow in the diffuse regime." Journal of Biomedical Optics , 2026, vol. 31, no. 02, 2026, p. 1. https://doi.org/10.1117/1.JBO.31.2.025002.
S. Aleman, A. D. Estrada, and A. B. Parthasarathy, "Comparing multi- and single-exposure speckle contrast optical spectroscopy methods as estimators of blood flow in the diffuse regime," Journal of Biomedical Optics , 2026, vol. 31, no. 02, p. 1, 2026, doi: 10.1117/1.JBO.31.2.025002.
@article{aleman2026comparing,
  title         = {{Comparing multi- and single-exposure speckle contrast optical spectroscopy methods as estimators of blood flow in the diffuse regime}},
  author        = {Aleman, Sean and Estrada, Arnold D. and Parthasarathy, Ashwin B.},
  year          = {2026},
  journal       = {Journal of Biomedical Optics , 2026},
  volume        = {31},
  number        = {02},
  pages         = {1},
  doi           = {10.1117/1.JBO.31.2.025002}
}

Added to the ChatPPG research hub