Paper

Deep CNN-based detection of cardiac rhythm disorders using PPG signals from wearable devices

Venue listedDated Feb 2025

Authors: Miray Gunay Bulut, Sencer Unal, Mohamed Hammad, Paweł Pławiak

PLOS ONE

TL;DR

This PLOS ONE paper trains a 1D CNN to detect heart rhythm disorders from 30-second PPG segments, using ECG from the same University of Massachusetts Medical Center dataset as the reference. It reported 95.17% accuracy in separating normal sinus rhythm, atrial fibrillation and premature atrial contractions. In July 2026 the PLOS ONE editors issued an Expression of Concern about retracted references and authorship policy compliance, advising readers to interpret the article with caution.

  • Data: UMMC Pulsewatch dataset, 30 s segments
  • Result: 95.17% accuracy (NSR / AF / PAC)
  • Notice: Expression of Concern, July 2026
  • Code: GitHub

Abstract

Cardiac rhythm disorders can manifest in various ways, such as the heart rate being too fast (tachycardia) or too slow (bradycardia), irregular heartbeats (like atrial fibrillation-AF, ventricular fibrillation-VF), or the initiation of heartbeats in different areas from the norm (extrasystole). Arrhythmias can disrupt the balanced circulation, leading to serious complications like heart attacks, strokes, and sudden death. Medical devices like electrocardiography (ECG) and Holter monitors are commonly used for diagnosing and monitoring cardiac rhythm disorders. However, in recent years, the development of wearable devices has played a significant role in the detection and diagnosis of rhythm disorders through the use of photoplethysmography (PPG) signals. Wearable devices enable patients to continuously monitor their health status and allow doctors to provide earlier diagnoses and interventions. In this study, a 1D-CNN model is proposed to detect arrhythmias using PPG signals. A dataset prepared by the University of Massachusetts Medical Center (UMMC) containing both ECG and PPG signal data was utilized. In this dataset, ECG signals are filtered with a bandpass filter and raw PPG signals are divided into 30-second segments. Accuracy values were obtained by classifying ECG and PPG signals using a 1D CNN model. ECG signals were used as a reference. The proposed model achieved a 95.17% accuracy rate in detecting normal sinus rhythm (NSR), atrial fibrillation (AF), and premature atrial contractions (PAC) from PPG signals. Datasets are available for download on https://www.synapse.org/pulsewatch . The codes used in this study are available on the https://github.com/miraygunay/PPG-Code.git website.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: http://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

How it works

How Method works: Setup → Method → ResultSetup: Signals (PPG (ECG reference)); Data (UMMC Pulsewatch dataset, 30 s segments). Method: Method. Result: Result (95.17% accuracy (NSR / AF / PAC)).SetupSignals: PPG (ECG reference)SignalsPPG (ECG reference)Data: UMMC Pulsewatch dataset, 30 s segmentsDataUMMC Pulsewatch dataset, 30 s segmentsMethodMethodResultResult: 95.17% accuracy (NSR / AF / PAC)Result95.17% accuracy (NSR / AF / PAC)

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Deep CNN-based detection of cardiac rhythm disorders using PPG signals from wearable devices. (2025). PLOS ONE. https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0314154
@article{deepcnnppgafibbu2025deep,
  title         = {{Deep CNN-based detection of cardiac rhythm disorders using PPG signals from wearable devices}},
  year          = {2025},
  journal       = {PLOS ONE},
  url           = {https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0314154}
}

Source metadata: 2025