Paperdoi:10.64898/2026.11.17.26368305
ProbeFit: one-seizure qualification and personalisation of multimodal wearable seizure detectors (SeizeIT2, 125 patients; predicts later sensitivity AUC 0.74–0.76 vs 0.59 for an HR rule)
medRxiv preprint (neurology), posted 2026-11-19
TL;DR
Preprint: ProbeFit uses the first recorded seizure to judge whether a multimodal wearable seizure detector will work for a given patient and to personalise it. On SeizeIT2 recordings (behind-the-ear EEG, ECG, EMG and movement) from 125 patients, developed on 96 and applied unchanged to 29 held-out patients, the qualification score identified patients with later sensitivity of at least 0.5 at AUC 0.74, and 0.76 across 97 evaluable patients versus 0.59 for a first-seizure heart-rate rule. At equal false-alarm rates, personalisation raised later sensitivity by 2.2 points in held-out patients.
Abstract
Background and Objective
Missed seizures hinder assessment of seizure frequency and treat-ment. Although wearables can detect seizures automatically, performance varies between pa-tients. Before deployment, it remains difficult to identify suitable patients, and personalisation usually requires several recorded seizures. We propose ProbeFit to predict later seizure sensi-tivity and personalise a wearable detector from the first recorded seizure.
Methods
We used multicentre SeizeIT2 recordings of behind-the-ear EEG, ECG, EMG and movement from 125 patients. Two generic detectors’ peak responses to the first seizure gener-ated a qualification probability. The same seizure and preceding background personalised the detector. ProbeFit was developed on 96 patients and applied unchanged to 29 held-out patients. Expert-labelled video-EEG seizures provided the reference. Evaluation compared qualification with the first-seizure heart-rate rule and measured discrimination, calibration and net benefit, and it compared later sensitivity of the generic and personalised detectors at equal false-alarm rates.
Results
Among 27 held-out patients with 152 later seizures, qualification correlated with later sensitivity at Spearman ρ = 0.38, with one-sided p = 0.033. It identified patients with later sensitivity ≥ 0.5 with an area under the ROC curve (AUC) of 0.74. Across all 97 evaluable patients, AUC was 0.76 against 0.59 for the heart-rate rule, a difference of 0.17 with a 95% confidence interval of 0.05 to 0.29. At the qualification threshold of 0.5, ProbeFit withheld deployment from 9 of 15 held-out patients below the sensitivity criterion, and its net benefit was 0.074 against −0.111 for selecting everyone. At equal false-alarm rates between 0.25 and 2 per day, personalisation raised later sensitivity by 2.2 percentage points in held-out patients and by 6.3 points in development patients. Both confidence intervals excluded zero, and no held-out patient lost sensitivity.
Conclusions
ProbeFit uses the first recorded seizure to predict whether a wearable detector will detect at least half of a patient’s later seizures, and it personalises that detector without waiting for further seizures. It supports patient selection and adaptation during the first moni-toring admission.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://www.medrxiv.org/about/FAQ#license
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Signals
Keywords
Datasets used
How it works
Cite this paper
Cui, H., Zhu, Y., Huang, S., & Xu, T. (2026). ProbeFit: one-seizure qualification and personalisation of multimodal wearable seizure detectors (SeizeIT2, 125 patients; predicts later sensitivity AUC 0.74–0.76 vs 0.59 for an HR rule). medRxiv preprint , posted. https://doi.org/10.64898/2026.11.17.26368305
Cui, Han, Yuge Zhu, Shaojia Huang, and Tao Xu. 2026. "ProbeFit: one-seizure qualification and personalisation of multimodal wearable seizure detectors (SeizeIT2, 125 patients; predicts later sensitivity AUC 0.74–0.76 vs 0.59 for an HR rule)." medRxiv preprint , posted. https://doi.org/10.64898/2026.11.17.26368305.
Cui, H., Zhu, Y., Huang, S. and Xu, T. (2026) 'ProbeFit: one-seizure qualification and personalisation of multimodal wearable seizure detectors (SeizeIT2, 125 patients; predicts later sensitivity AUC 0.74–0.76 vs 0.59 for an HR rule)', medRxiv preprint , posted. doi: 10.64898/2026.11.17.26368305.
Cui, Han, et al. "ProbeFit: one-seizure qualification and personalisation of multimodal wearable seizure detectors (SeizeIT2, 125 patients; predicts later sensitivity AUC 0.74–0.76 vs 0.59 for an HR rule)." medRxiv preprint , posted, 2026. https://doi.org/10.64898/2026.11.17.26368305.
H. Cui, Y. Zhu, S. Huang, and T. Xu, "ProbeFit: one-seizure qualification and personalisation of multimodal wearable seizure detectors (SeizeIT2, 125 patients; predicts later sensitivity AUC 0.74–0.76 vs 0.59 for an HR rule)," medRxiv preprint , posted, 2026, doi: 10.64898/2026.11.17.26368305.
@misc{cui2026probefit,
title = {{ProbeFit: one-seizure qualification and personalisation of multimodal wearable seizure detectors (SeizeIT2, 125 patients; predicts later sensitivity AUC 0.74–0.76 vs 0.59 for an HR rule)}},
author = {Cui, Han and Zhu, Yuge and Huang, Shaojia and Xu, Tao},
year = {2026},
howpublished = {medRxiv preprint , posted},
doi = {10.64898/2026.11.17.26368305}
}Added to the ChatPPG research hub