Paperdoi:10.3390/s26227229
TinyML-Based Photoplethysmography (PPG) Analysis for Atrial Fibrillation Detection
Sensors (MDPI), published 2026-11-16
TL;DR
Compares CNN, autoencoder and Transformer PPG AF classifiers on MIMIC PERform AF and ports the Transformer to an nRF52840. Post-training quantization dropped average accuracy from 98.66% to 95.23%; quantization-aware training avoided the drop. Unsupported TFLite Micro layers were replaced and multi-head attention approximated with a CNN block, giving a 107 KB model at 98.09% accuracy on device.
- Form factor: fingertip ICU PPG for training (MIMIC PERform AF); edge target nRF52840
Abstract
This paper proposes an atrial fibrillation detection algorithm using PPG signals and presents a method to port it to edge devices such as the nRF52840. To classify the PPG signals, simple CNN-based, Autoencoder-based, and Transformer-based Deep Neural Networks (DNNs) were implemented and comparatively analyzed using the MIMIC PERform AF dataset. As a result, the Transformer-based algorithm exhibited the best performance with an average accuracy of 98.66%. While post-training quantization (PTQ) of the Transformer-based algorithm caused the average accuracy to degrade to 95.23%, applying Quantization-Aware Training (QAT) prevented this performance drop. Because some layers of the Transformer are not supported in TensorFlow Lite for Microcontrollers (TFLite Micro), they were modified, and the Multi-Head Attention was approximated using a CNN-based network for porting to the edge device, resulting in a final model size of 107 KB. The ported network demonstrated excellent performance, maintaining an average accuracy of 98.09%.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
Datasets used
How it works
Cite this paper
Choi, K. (2026). TinyML-Based Photoplethysmography (PPG) Analysis for Atrial Fibrillation Detection. Sensors. https://doi.org/10.3390/s26227229
Choi, Kyoungtaek. 2026. "TinyML-Based Photoplethysmography (PPG) Analysis for Atrial Fibrillation Detection." Sensors. https://doi.org/10.3390/s26227229.
Choi, K. (2026) 'TinyML-Based Photoplethysmography (PPG) Analysis for Atrial Fibrillation Detection', Sensors. doi: 10.3390/s26227229.
Choi, Kyoungtaek "TinyML-Based Photoplethysmography (PPG) Analysis for Atrial Fibrillation Detection." Sensors, 2026. https://doi.org/10.3390/s26227229.
K. Choi, "TinyML-Based Photoplethysmography (PPG) Analysis for Atrial Fibrillation Detection," Sensors, 2026, doi: 10.3390/s26227229.
@article{choi2026tinymlbased,
title = {{TinyML-Based Photoplethysmography (PPG) Analysis for Atrial Fibrillation Detection}},
author = {Choi, Kyoungtaek},
year = {2026},
journal = {Sensors},
publisher = {MDPI},
doi = {10.3390/s26227229}
}Added to the ChatPPG research hub