Paperdoi:10.1364/BOE.494720
Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage
Biomedical Optics Express 14(10):5338–5357, 2023 (preprint bioRxiv 10.1101/2023.02.20.529156)
TL;DR
A low-cost wearable laser speckle sensor measured peripheral blood flow (laser speckle flow index) to catch the vasoconstriction the body uses to compensate for bleeding. In six pigs with controlled blood loss, the flow index tracked blood-volume loss with a correlation of −0.95, outperforming the standard shock index, and tracked recovery during resuscitation. The work targets early detection of postpartum hemorrhage.
- Form factor: other
Abstract
Postpartum hemorrhage (PPH) is the leading and most preventable cause of maternal mortality, particularly in low-resource settings. PPH is currently diagnosed through visual estimation of blood loss or monitoring of vital signs. Visual assessment routinely underestimates blood loss beyond the point of pharmaceutical intervention. Quantitative monitoring of hemorrhage-induced compensatory processes, such as the constriction of peripheral vessels, may provide an early alert for PPH. To this end, we developed a low-cost, wearable optical device that continuously monitors peripheral perfusion via laser speckle flow index (LSFI) to detect hemorrhage-induced peripheral vasoconstriction. The measured LSFI signal produced a linear response in phantom models and a strong correlation coefficient with blood loss averaged across subjects (>0.9) in a large animal model, with superior performance to vital sign metrics.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://doi.org/10.1364/OA_License_v2#VOR-OA
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Signals
Keywords
How it works
- Wavelengths
- laser (λ not in abstract)
Cite this paper
Bonetta-Misteli, F., Collins, T., Pavek, T., Carlgren, M., Bashe, D., Frolova, A., Shmuylovich, L., & O'Brien, C. M. (2023). Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage. Biomedical Optics Express , 2023, 14(10), 5338–5357. https://doi.org/10.1364/BOE.494720
Bonetta-Misteli, Francesca, Toi Collins, Todd Pavek, Madison Carlgren, Dara Bashe, Antonina Frolova, Leonid Shmuylovich, and Christine M. O'Brien. 2023. "Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage." Biomedical Optics Express , 2023 14 (10): 5338–5357. https://doi.org/10.1364/BOE.494720.
Bonetta-Misteli, F., Collins, T., Pavek, T., Carlgren, M., Bashe, D., Frolova, A., Shmuylovich, L. and O'Brien, C. M. (2023) 'Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage', Biomedical Optics Express , 2023, 14(10), pp. 5338–5357. doi: 10.1364/BOE.494720.
Bonetta-Misteli, Francesca, et al. "Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage." Biomedical Optics Express , 2023, vol. 14, no. 10, 2023, pp. 5338–5357. https://doi.org/10.1364/BOE.494720.
F. Bonetta-Misteli et al., "Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage," Biomedical Optics Express , 2023, vol. 14, no. 10, pp. 5338–5357, 2023, doi: 10.1364/BOE.494720.
@article{bonettamisteli2023development,
title = {{Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage}},
author = {Bonetta-Misteli, Francesca and Collins, Toi and Pavek, Todd and Carlgren, Madison and Bashe, Dara and Frolova, Antonina and Shmuylovich, Leonid and O'Brien, Christine M.},
year = {2023},
journal = {Biomedical Optics Express , 2023},
volume = {14},
number = {10},
pages = {5338--5357},
doi = {10.1364/BOE.494720}
}Added to the ChatPPG research hub