Paperdoi:10.3390/s26227356

A Pulse Ahead: Cross-Modal Knowledge Distillation from Arterial Blood Pressure to Photoplethysmography for Compensatory Reserve Prediction

Venue listed2026Added Nov 23, 2026

  • BP

Authors: Benjamin J. McCloskey; Michael L. Tibbs; Lonnie G. Petersen

Sensors 26(22):7356 (published 2026-11-20)

TL;DR

Cross-modal distillation that aligns a lightweight PPG transformer's embeddings with ABP-trained Vision Transformer teachers for compensatory reserve measurement (CRM). In 9 subjects under graded lower body negative pressure (ground and in aeromedical evacuation flight), the PPG-only student reached held-out R² 0.616 (0.714 ground, 0.525 flight) versus −0.264 when the ABP model was fed PPG directly, with AUC 0.92 for critically low CRM.

  • Form factor: PPG (site not stated in abstract)

Abstract

The Compensatory Reserve Measurement (CRM) provides high-fidelity situational awareness of a patient’s proximity to hemodynamic decompensation, yet existing CRM models depend on arterial blood pressure (ABP) waveforms that are largely inaccessible in prehospital settings. Photoplethysmography (PPG) offers a field-deployable alternative, but state-of-the-art CRM models are trained on ABP waveforms. Prior efforts have therefore forwarded PPG through ABP-trained convolutional networks, producing out-of-distribution predictions. We present a cross-modal distillation framework that aligns PPG representations with embeddings from ABP-trained CRM Vision Transformer (ViT) teachers, transferring arterial waveform information to PPG. Time-aligned ABP and PPG waveforms were collected from nine human subjects during graded lower body negative pressure (LBNP) simulating progressive hemorrhage, both on the ground and during aeromedical evacuation flight. A lightweight transformer student encoder was trained using latent representation alignment and fine-tuned for CRM regression on PPG inputs alone. The model achieved an R2 of 0.616 on held-out subjects (0.714 ground, 0.525 flight), substantially outperforming the direct application of the ABP-trained model on PPG (R2=−0.264). The detection of critically low CRM yielded an area under the curve of 0.92, and predicted CRM tracked LBNP more closely than the arterial teacher (Spearman ρ=0.791 vs. 0.691). These findings support the feasibility of PPG-based CRM estimation for physiological monitoring during emergency first response.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Compensatory ReserveCRMHemorrhageLBNPHypovolemiaKnowledge DistillationCross ModalABP to PPG

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG, ABP); Form factor (PPG (site not stated in abstract)). Method: Method (Transformer).SetupSignals: PPG, ABPSignalsPPG, ABPForm factor: PPG (site not stated in abstract)Form factorPPG (site not stated in abstract)Method×NMethodTransformer

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

McCloskey, B. J., Tibbs, M. L., & Petersen, L. G. (2026). A Pulse Ahead: Cross-Modal Knowledge Distillation from Arterial Blood Pressure to Photoplethysmography for Compensatory Reserve Prediction. Sensors, 26(22), 7356. https://doi.org/10.3390/s26227356
McCloskey, Benjamin J., Michael L. Tibbs, and Lonnie G. Petersen. 2026. "A Pulse Ahead: Cross-Modal Knowledge Distillation from Arterial Blood Pressure to Photoplethysmography for Compensatory Reserve Prediction." Sensors 26 (22): 7356. https://doi.org/10.3390/s26227356.
McCloskey, B. J., Tibbs, M. L. and Petersen, L. G. (2026) 'A Pulse Ahead: Cross-Modal Knowledge Distillation from Arterial Blood Pressure to Photoplethysmography for Compensatory Reserve Prediction', Sensors, 26(22), p. 7356. doi: 10.3390/s26227356.
McCloskey, Benjamin J., et al. "A Pulse Ahead: Cross-Modal Knowledge Distillation from Arterial Blood Pressure to Photoplethysmography for Compensatory Reserve Prediction." Sensors, vol. 26, no. 22, 2026, p. 7356. https://doi.org/10.3390/s26227356.
B. J. McCloskey, M. L. Tibbs, and L. G. Petersen, "A Pulse Ahead: Cross-Modal Knowledge Distillation from Arterial Blood Pressure to Photoplethysmography for Compensatory Reserve Prediction," Sensors, vol. 26, no. 22, p. 7356, 2026, doi: 10.3390/s26227356.
@article{mccloskey2026pulse,
  title         = {{A Pulse Ahead: Cross-Modal Knowledge Distillation from Arterial Blood Pressure to Photoplethysmography for Compensatory Reserve Prediction}},
  author        = {McCloskey, Benjamin J. and Tibbs, Michael L. and Petersen, Lonnie G.},
  year          = {2026},
  journal       = {Sensors},
  volume        = {26},
  number        = {22},
  pages         = {7356},
  doi           = {10.3390/s26227356}
}

Added to the ChatPPG research hub