Paperdoi:10.1364/OL.38.001401

Deep tissue flowmetry based on diffuse speckle contrast analysis

Venue listed2013Added Oct 29, 2026

  • RB
  • JD
  • KU

Authors: Renzhe Bi, Jing Dong, Kijoon Lee (Nanyang Technological University)

Optics Letters 38(9):1401, 2013

TL;DR

Diffuse speckle contrast analysis (DSCA) showed that deep-tissue blood-flow information similar to diffuse correlation spectroscopy can be obtained from a simple camera image of the speckle pattern instead of expensive single-photon counters. It was demonstrated on a flow phantom and during cuff occlusion in vivo.

  • Form factor: lab

Abstract

Diffuse correlation spectroscopy (DCS) is an emerging modality for noninvasive deep tissue blood flow monitoring that is becoming increasingly popular; it conducts an autocorrelation analysis of fast fluctuating photon count signals from a single speckle. In this Letter, we show that the same level of deep tissue flow information can be obtained from a much simpler analysis on the spatial distribution of the speckles that is obtained by a CCD camera, which we named diffuse speckle contrast analysis (DSCA). Both the flow phantom experiment and in vivo cuff occlusion data are presented. DSCA can be considered a new optical modality that combines DCS and laser speckle contrast imaging (LSCI), which exploits simple instrumentation and analysis and yet is sensitive to deep tissue flow.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Speckle PlethysmographyFoundationsDiffuseDeep TissueNtu

How it works

How Method works: Setup → Method → TargetSetup: Signals (DSCA); Wavelengths (NIR laser (λ not in abstract)); Form factor (lab). Method: Method.SetupSignals: DSCASignalsDSCAWavelengths: NIR laser (λ not in abstract)WavelengthsNIR laser (λ not in abstract)Form factor: labForm factorlabMethodMethod
Wavelengths
NIR laser (λ not in abstract)

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Bi, R., Dong, J., & Lee, K. (2013). Deep tissue flowmetry based on diffuse speckle contrast analysis. Optics Letters , 2013, 38(9), 1401. https://doi.org/10.1364/OL.38.001401
Bi, Renzhe, Jing Dong, and Kijoon Lee. 2013. "Deep tissue flowmetry based on diffuse speckle contrast analysis." Optics Letters , 2013 38 (9): 1401. https://doi.org/10.1364/OL.38.001401.
Bi, R., Dong, J. and Lee, K. (2013) 'Deep tissue flowmetry based on diffuse speckle contrast analysis', Optics Letters , 2013, 38(9), p. 1401. doi: 10.1364/OL.38.001401.
Bi, Renzhe, et al. "Deep tissue flowmetry based on diffuse speckle contrast analysis." Optics Letters , 2013, vol. 38, no. 9, 2013, p. 1401. https://doi.org/10.1364/OL.38.001401.
R. Bi, J. Dong, and K. Lee, "Deep tissue flowmetry based on diffuse speckle contrast analysis," Optics Letters , 2013, vol. 38, no. 9, p. 1401, 2013, doi: 10.1364/OL.38.001401.
@article{bi2013deep,
  title         = {{Deep tissue flowmetry based on diffuse speckle contrast analysis}},
  author        = {Bi, Renzhe and Dong, Jing and Lee, Kijoon},
  year          = {2013},
  journal       = {Optics Letters , 2013},
  volume        = {38},
  number        = {9},
  pages         = {1401},
  doi           = {10.1364/OL.38.001401}
}

Added to the ChatPPG research hub