Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.
This entry covers the PPG and ECG foundation models from Apple described in "Large-scale Training of Foundation Models for Wearable Biosignals" by Salar Abbaspourazad, Oussama Elachqar, Andrew C. Miller, Saba Emrani, Udhyakumar Nallasamy and Ian Shapiro. The camera-ready version appeared at ICLR 2024; the paper lists Apple as the authors' affiliation.
The motivation is a common one in wearable health. Watches record a lot of biosignal data, but medical labels are scarce and medical datasets tend to be small. The authors used self-supervised learning on unlabeled data from the Apple Heart and Movement Study (AHMS), collected under informed consent, to train separate foundation models for two signals recorded on Apple Watch: PPG and ECG. The curated datasets include data from about 141K participants spanning about 3 years.
The training recipe has three parts: positive pairs chosen at the participant level, a stochastic augmentation module, and a regularized contrastive loss trained with a momentum (exponential moving average) encoder. The regularizer is a KoLeo differential entropy estimator that spreads embeddings out within each batch. The same framework works for both PPG and ECG.
The paper's main finding is that the pre-trained embeddings encode information about participants' demographics and health conditions, which makes them useful starting points for new digital biomarkers with fewer labels. The authors describe it as the first study to build PPG and ECG foundation models from large-scale data collected with consumer wearables, where earlier work had mostly relied on smaller clinical or experimental datasets.
There is no public download. Because of the consent terms of AHMS, the authors state that they cannot share the sensor data, and code may be available on request from the corresponding author. In practice the model is a reference point. The Pulse-PPG authors describe it as a closed-source model whose weights and training data are private. Apple's later Wearable Behavioral Model also draws on the Apple Heart and Movement Study.
Signals
PPG, ECG
Year
2023
Paper
Large-scale Training of Foundation Models for Wearable Biosignals (Abbaspourazad et al.), ICLR 2024
Data
Apple Heart and Movement Study (AHMS), about 141K participants spanning about 3 years
Method
participant-level positive pairs, stochastic augmentations, regularized contrastive loss (KoLeo) with momentum training
Finding
embeddings encode participant demographics and health conditions
Availability
sensor data cannot be shared; code may be available on request
Demographics from PPG · Apple Heart and Movement Study
age regression · linear probe (ridge) on participant-mean embeddings
Best comparison: ECG encoder (participant-level) 6.33
Results as reported by the authors; not independently reproduced. A SOTA star marks the best value among results reported under the same evaluation protocol; ties go to the earlier publication.
Tracking biosignals is crucial for monitoring wellness and preempting the development of severe medical conditions. Today, wearable devices can conveniently record various biosignals, creating the opportunity to monitor health status without disruption to one's daily routine. Despite widespread use of wearable devices and existing digital biomarkers, the absence of curated data with annotated medical labels hinders the development of new biomarkers to measure common health conditions. In fact, medical datasets are usually small in comparison to other domains, which is an obstacle for developing neural network models for biosignals. To address this challenge, we have employed self-supervised learning using the unlabeled sensor data collected under informed consent from the large longitudinal Apple Heart and Movement Study (AHMS) to train foundation models for two common biosignals: photoplethysmography (PPG) and electrocardiogram (ECG) recorded on Apple Watch. We curated PPG and ECG datasets from AHMS that include data from ~141K participants spanning ~3 years. Our self-supervised learning framework includes participant level positive pair selection, stochastic augmentation module and a regularized contrastive loss optimized with momentum training, and generalizes well to both PPG and ECG modalities. We show that the pre-trained foundation models readily encode information regarding participants' demographics and health conditions. To the best of our knowledge, this is the first study that builds foundation models using large-scale PPG and ECG data collected via wearable consumer devices x2013 prior works have commonly used smaller-size datasets collected in clinical and experimental settings. We believe PPG and ECG foundation models can enhance future wearable devices by reducing the reliance on labeled data and hold the potential to help the users improve their health.
Verbatim fromarXiv· arXiv metadata (abstracts are released under CC0)
How it works
Architecture
1D-EfficientNet-style CNN (16 MBConv blocks); separate PPG and ECG encoders
It is a self-supervised foundation model for Apple Watch PPG (with a sister ECG model) trained on data from about 141K participants in the Apple Heart and Movement Study, described in the ICLR 2024 paper Large-scale Training of Foundation Models for Wearable Biosignals.
Can I download Apple's PPG foundation model?
No. The paper says the AHMS sensor data cannot be shared, and code may be available on request from the corresponding author. Open alternatives include PaPaGei and Pulse-PPG.
Apple PPG foundation model vs PaPaGei?
Apple's model was trained on Apple Watch PPG from about 141K participants and is not released. PaPaGei is open, with weights on Zenodo, and was pre-trained on more than 57,000 hours of public clinical PPG.
What did the Apple biosignal foundation model show?
The paper reports that the pre-trained PPG and ECG embeddings encode participants' demographics and health conditions, which supports building new biomarkers with less labeled data.
Cite this model
Cite the publication recorded for this model. Check it against the publisher before submitting.
Abbaspourazad, S., Elachqar, O., Miller, A. C., Emrani, S., Nallasamy, U., & Shapiro, I. (2023). Large-scale Training of Foundation Models for Wearable Biosignals. ICLR 2024. https://doi.org/10.48550/ARXIV.2312.05409
Abbaspourazad, Salar, Oussama Elachqar, Andrew C. Miller, Saba Emrani, Udhyakumar Nallasamy, and Ian Shapiro. 2023. "Large-scale Training of Foundation Models for Wearable Biosignals." ICLR 2024. https://doi.org/10.48550/ARXIV.2312.05409.
Abbaspourazad, S., Elachqar, O., Miller, A. C., Emrani, S., Nallasamy, U. and Shapiro, I. (2023) 'Large-scale Training of Foundation Models for Wearable Biosignals', ICLR 2024. doi: 10.48550/ARXIV.2312.05409.
Abbaspourazad, Salar, et al. "Large-scale Training of Foundation Models for Wearable Biosignals." ICLR 2024, 2023. https://doi.org/10.48550/ARXIV.2312.05409.
S. Abbaspourazad, O. Elachqar, A. C. Miller, S. Emrani, U. Nallasamy, and I. Shapiro, "Large-scale Training of Foundation Models for Wearable Biosignals," ICLR 2024, 2023, doi: 10.48550/ARXIV.2312.05409.
@misc{abbaspourazad2023largescale,
title = {{Large-scale Training of Foundation Models for Wearable Biosignals}},
author = {Abbaspourazad, Salar and Elachqar, Oussama and Miller, Andrew C. and Emrani, Saba and Nallasamy, Udhyakumar and Shapiro, Ian},
year = {2023},
howpublished = {ICLR 2024},
publisher = {arXiv},
doi = {10.48550/ARXIV.2312.05409},
eprint = {2312.05409},
archivePrefix = {arXiv}
}
History
Record updated
Added to the ChatPPG research hub
Newsletter
Get new PPG datasets, papers and models
Get alerts when Apple wearable biosignals FM is benchmarked on new datasets, plus the weekly digest.
New datasets, papers and models
Practical guides from the hub
Unsubscribe anytime
The waveform is an illustration of a PPG pulse, not a recording.