Foundation model

ECG-JEPA (Samsung Medical Center; 12-lead ECG JEPA)

Year
2026
Form factor
Clinical
ECGOpen codeWeights: open
Kim, Sehun, "Learning General Representation of 12-Lead Electrocardiogram with a Joint-Embedding Predictive Architecture", arXiv:2410.08559, CC BY 4.0
Venue listedCatalog paper date: 2026Added to atlas: Oct 21, 2026Source

Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.

ECG-JEPA is a 12-lead ECG foundation model that adapts joint-embedding predictive architecture training with cross-pattern attention for multi-lead structure. Code and weights are released; the work appears in Neural Networks 2026 (arXiv 2410.08559; DOI 10.1016/j.neunet.2026.109334).

Signals
ECG
Form factor
Clinical
Year
2026
Architecture

JEPA: ViT student/teacher (12 layers, 16 heads, 768-d) + predictor (6 layers, 12 heads, 384-d) regressing EMA-teacher latents of masked patches; Cross-Pattern Attention (CroPA) masked attention for 12-lead structure; random or multi-block masking

Pretraining data

Chapman + Ningbo (43,240) + CODE-15 (130,900) 10-s 12-lead ECGs ≈ 174k (paper rounds to ~180k)

License

MIT (code repository); checkpoints: no separate licence stated

At a glance
Type
Foundation model
Modalities
ECG
Form factor
Clinical
Parameters
Not reported
Architecture
JEPA: ViT student/teacher (12 layers, 16 heads, 768-d) + predictor (6 layers, 12 heads, 384-d) regressing EMA-teacher latents of masked patches; Cross-Pattern Attention (CroPA) masked attention for 12-lead structure; random or multi-block masking
Venue
Not reported
Year
2026
Weights
Open
Licence
MIT (code repository); checkpoints: no separate licence stated
Caveats
Not reported
Added
Oct 21, 2026
Updated
Oct 26, 2026

Abstract

Electrocardiogram (ECG) captures the heart's electrical signals, offering valuable information for diagnosing cardiac conditions. However, the scarcity of labeled data makes it challenging to fully leverage supervised learning in the medical domain. Self-supervised learning (SSL) offers a promising solution, enabling models to learn from unlabeled data and uncover meaningful patterns. In this paper, we show that masked modeling in the latent space can be a powerful alternative to existing self-supervised methods in the ECG domain. We introduce ECG-JEPA, an SSL model for 12-lead ECG analysis that learns semantic representations of ECG data by predicting in the hidden latent space, bypassing the need to reconstruct raw signals. This approach offers several advantages in the ECG domain: (1) it avoids producing unnecessary details, such as noise, which is common in ECG; and (2) it addresses the limitations of naive L2 loss between raw signals. Another key contribution is the introduction of Cross-Pattern Attention (CroPA), a specialized masked attention mechanism tailored for 12-lead ECG data. ECG-JEPA is trained on the union of several open ECG datasets, totaling approximately 180,000 samples, and achieves state-of-the-art performance in various downstream tasks including diagnostic classification, feature extraction, and segmentation. Our code is openly available at https://github.com/sehunfromdaegu/ECG_JEPA.

Verbatim fromarXiv· arXiv metadata (abstracts are released under CC0)

How it works

How ECG-JEPA (Samsung Medical Center; 12-lead ECG JEPA) works: Input signals → Foundation model → Downstream tasksInput signals: ECG (Electrocardiogram). Datasets: Chapman–Shaoxing–Ningbo 12-lead ECG arrhythmia database (PhysioNet), CODE-15%: large annotated 12-lead ECG dataset (Telehealth Network of Minas Gerais), PTB-XL. Foundation model: ECG-JEPA (Samsung Medical Center; 12-lead ECG JEPA) (Transformer · Convolutional network).Input signalsECG: ElectrocardiogramECGElectrocardiogramDatasets: Chapman–Shaoxing–Ningbo 12-lead ECG arrhythmia database (PhysioNet), CODE-15%: large annotated 12-lead ECG dataset (Telehealth Network of Minas Gerais), PTB-XLDatasetsChapman–Shaoxing–Ningbo 12-lead ECG…Foundation model×NECG-JEPA (Samsung Medical…Transformer · Convolutional network

Datasets linked in the hub; pretraining vs evaluation roles follow the paper.

Pretraining data
Chapman + Ningbo (43,240) + CODE-15 (130,900) 10-s 12-lead ECGs ≈ 174k (paper rounds to ~180k)
Architecture
JEPA: ViT student/teacher (12 layers, 16 heads, 768-d) + predictor (6 layers, 12 heads, 384-d) regressing EMA-teacher latents of masked patches; Cross-Pattern Attention (CroPA) masked attention for 12-lead structure; random or multi-block masking
Inputs
ECG
Approach
foundation model · ECG · JEPA · self supervised · CroPA · open weights

Datasets· 3

Papers· 1

Cite

APA

ECG-JEPA: Learning General Representation of 12-Lead ECG with a Joint-Embedding Predictive Architecture. (2026). Neural Networks. https://doi.org/10.1016/j.neunet.2026.109334

BibTeX

@article{ecgjepa2026ecgjepa,
  title         = {{ECG-JEPA: Learning General Representation of 12-Lead ECG with a Joint-Embedding Predictive Architecture}},
  year          = {2026},
  journal       = {Neural Networks},
  doi           = {10.1016/j.neunet.2026.109334},
  eprint        = {2410.08559},
  archivePrefix = {arXiv}
}

Built from the hub record. Check it against the publisher before submitting.

History

  1. Record updated

  2. Added to the ChatPPG research hub