ECG-JEPA (Samsung Medical Center; 12-lead ECG JEPA)
- Year
- 2026
- Form factor
- Clinical
Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.
ECG-JEPA is a 12-lead ECG foundation model that adapts joint-embedding predictive architecture training with cross-pattern attention for multi-lead structure. Code and weights are released; the work appears in Neural Networks 2026 (arXiv 2410.08559; DOI 10.1016/j.neunet.2026.109334).
- Signals
- ECG
- Form factor
- Clinical
- Year
- 2026
- Architecture
JEPA: ViT student/teacher (12 layers, 16 heads, 768-d) + predictor (6 layers, 12 heads, 384-d) regressing EMA-teacher latents of masked patches; Cross-Pattern Attention (CroPA) masked attention for 12-lead structure; random or multi-block masking
- Pretraining data
Chapman + Ningbo (43,240) + CODE-15 (130,900) 10-s 12-lead ECGs ≈ 174k (paper rounds to ~180k)
- License
MIT (code repository); checkpoints: no separate licence stated
- Type
- Foundation model
- Modalities
- ECG
- Form factor
- Clinical
- Parameters
- Not reported
- Architecture
- JEPA: ViT student/teacher (12 layers, 16 heads, 768-d) + predictor (6 layers, 12 heads, 384-d) regressing EMA-teacher latents of masked patches; Cross-Pattern Attention (CroPA) masked attention for 12-lead structure; random or multi-block masking
- Venue
- Not reported
- Year
- 2026
- Weights
- Open
- Licence
- MIT (code repository); checkpoints: no separate licence stated
- Caveats
- Not reported
- Datasets
- Added
- Oct 21, 2026
- Updated
- Oct 26, 2026
Abstract
Electrocardiogram (ECG) captures the heart's electrical signals, offering valuable information for diagnosing cardiac conditions. However, the scarcity of labeled data makes it challenging to fully leverage supervised learning in the medical domain. Self-supervised learning (SSL) offers a promising solution, enabling models to learn from unlabeled data and uncover meaningful patterns. In this paper, we show that masked modeling in the latent space can be a powerful alternative to existing self-supervised methods in the ECG domain. We introduce ECG-JEPA, an SSL model for 12-lead ECG analysis that learns semantic representations of ECG data by predicting in the hidden latent space, bypassing the need to reconstruct raw signals. This approach offers several advantages in the ECG domain: (1) it avoids producing unnecessary details, such as noise, which is common in ECG; and (2) it addresses the limitations of naive L2 loss between raw signals. Another key contribution is the introduction of Cross-Pattern Attention (CroPA), a specialized masked attention mechanism tailored for 12-lead ECG data. ECG-JEPA is trained on the union of several open ECG datasets, totaling approximately 180,000 samples, and achieves state-of-the-art performance in various downstream tasks including diagnostic classification, feature extraction, and segmentation. Our code is openly available at https://github.com/sehunfromdaegu/ECG_JEPA.
Verbatim fromarXiv· arXiv metadata (abstracts are released under CC0)
How it works
Datasets linked in the hub; pretraining vs evaluation roles follow the paper.
- Pretraining data
- Chapman + Ningbo (43,240) + CODE-15 (130,900) 10-s 12-lead ECGs ≈ 174k (paper rounds to ~180k)
- Architecture
- JEPA: ViT student/teacher (12 layers, 16 heads, 768-d) + predictor (6 layers, 12 heads, 384-d) regressing EMA-teacher latents of masked patches; Cross-Pattern Attention (CroPA) masked attention for 12-lead structure; random or multi-block masking
- Inputs
- ECG
- Approach
- foundation model · ECG · JEPA · self supervised · CroPA · open weights
Datasets· 3
Papers· 1
Cite
APA
ECG-JEPA: Learning General Representation of 12-Lead ECG with a Joint-Embedding Predictive Architecture. (2026). Neural Networks. https://doi.org/10.1016/j.neunet.2026.109334
BibTeX
@article{ecgjepa2026ecgjepa,
title = {{ECG-JEPA: Learning General Representation of 12-Lead ECG with a Joint-Embedding Predictive Architecture}},
year = {2026},
journal = {Neural Networks},
doi = {10.1016/j.neunet.2026.109334},
eprint = {2410.08559},
archivePrefix = {arXiv}
}Built from the hub record. Check it against the publisher before submitting.
History
Record updated
Added to the ChatPPG research hub
Connections
Open in the graph explorerPapers
ECG-JEPA: Learning General Representation of 12-Lead ECG with a Joint-Embedding Predictive ArchitecturePaper on this modelNeural Networks · 2027
QECGBERT: a scalable ECG foundation model based on self-supervised language learning via VQ-VAE waveform tokenizationAlso uses Chapman–Shaoxing–Ningbo 12-lead ECG arrhythmia database (PhysioNet)arXiv 2610.33964v1 · 2026
SimAuthor: Harnessing Foundation Models for Persistent Scientific Simulator AuthoringAlso uses Chapman–Shaoxing–Ningbo 12-lead ECG arrhythmia database (PhysioNet)arXiv preprint · 2026
Models
IECGAlso uses Chapman–Shaoxing–Ningbo 12-lead ECG arrhythmia database (PhysioNet)weakly-supervised interpretability-enhancing ECG foundation modelFoundation modelECGText2026
QECGBERT (VQ-VAE beat-token BERT ECG FM; Afghah lab)Also uses Chapman–Shaoxing–Ningbo 12-lead ECG arrhythmia database (PhysioNet)Foundation modelECG2026