}ToLife provides simultaneous consumer-watch wrist PPG, contact finger PPG, and ECG. It is especially useful for learning timing/rate relationships and testing cross-site representations without assuming that fingertip contour or amplitude is preserved at the wrist.
This dataset was created in the context of the EU project Tolife, which aims at validating an artificial intelligence solution to process daily life patient data captured by non-obtrusive sensors to enable personalized treatment, assessment of health outcomes and improved quality of life in chronic obstructive pulonary disease patients.
In the last years, commercial smartwatches have gained popularity as non-invasive and wearable devices to be exploited for the monitoring of the cardiovascular system in daily-life settings. However, their reliability is still unclear. To this aim, we have created a dataset to evaluate the accuracy of heart rate (HR) and HR variability (HRV) estimates obtained from the Samsung Galaxy Watch 5 (SGW5) compared to a common research-grade ECG sensor, i.e., the Shimmer3 ECG unit (ShimECG), during both a resting and walking condition.
The dataset consiststs of photopletismographic (PPG) signal acquired using the SGW5 and Shimmer GSR+, as well as ECG signal acquired using the Shimmer3 ECG, from 20 healthy volunteers performing 1min of resting-state with the arm resting on a table and 1min of walk respectively.
Both PPG and ECG data have been synchronized using their respective timestamps.
The data is given without any preprocessing.
Shimmer PPG and ECG data is sampled at 404Hz.
SGW5 PPG data is sampled at 25Hz.
When using this dataset, please cite Rho, Gianluca, et al. "Preliminary Assessment of the Samsung Galaxy Watch 5 Accuracy for the Monitoring of Heart Rate and Heart Rate Variability Parameters." Mediterranean Conference on Medical and Biological Engineering and Computing. Cham: Springer Nature Switzerland, 2023.
Verbatim fromZenodo· Licence: cc-by-4.0

No model in the hub reports results on this dataset yet.


Full photo credits and licences are on each device page. An icon means we have no openly licensed or manufacturer-cleared photo of that exact device yet.
ToLife has data from 20 subjects, as listed in its research record.
ToLife includes PPG and ECG data. Sampling rate as recorded: Galaxy Watch 5 wrist PPG 25 Hz; Shimmer finger PPG 404 Hz; Shimmer ECG reported as 400 or 404 Hz depending on release metadata. Raw waveforms are included.
It is hosted on Zenodo at https://zenodo.org/records/10717903. No licence is recorded for it here, so check the terms on the source page before you use it.
Yes. Its record lists wrist-worn recording.
ToLife [Data set]. (n.d.). zenodo. https://doi.org/10.5281/zenodo.10717903
@misc{tolifegw5tolife,
title = {{ToLife}},
howpublished = {zenodo},
doi = {10.5281/zenodo.10717903}
}Cite the dated snapshot 2026-10 for a fixed, reproducible version. Please also cite the original publications listed above.
ChatPPG. (2026). ToLife: dataset record (Version 2026-10) [Data set]. ChatPPG Research Hub. https://chatppg.com/research/datasets/tolife-gw5
@misc{chatppg_dataset_tolife_gw5,
author = {{ChatPPG}},
title = {{ToLife: dataset record}},
year = {2026},
month = nov,
version = {2026-10},
howpublished = {\url{https://chatppg.com/research/datasets/tolife-gw5}},
note = {ChatPPG Research Hub, Snapshot 2026-10, https://chatppg.com/research/snapshots/2026-10}
}cff-version: 1.2.0 message: "If you use this resource, please cite it as below." type: dataset title: "ToLife: dataset record" authors: - name: "ChatPPG" url: "https://chatppg.com/research/datasets/tolife-gw5" repository-artifact: "https://chatppg.com/research/snapshots/2026-10" version: "2026-10" date-released: "2026-11-13"
Record updated