Dataset

Continuous cuffless BP via graphene bioimpedance tattoos (PhysioNet)

This PhysioNet dataset measures blood pressure without a cuff using atomically thin graphene electronic tattoos that record bioimpedance over the radial and ulnar arteries at the wrist. It includes raw 4-channel bioimpedance with synchronized PPG and reference blood pressure from a Finapres NOVA. Seven people were monitored for about 4 hours each, giving 18,667 beat-level blood pressure data points.

Sensor
graphene e-tattoo bioimpedance (4 channels, wrist)
Reference
Finapres NOVA continuous BP
Size
18,667 BP data points (~4 h per person)
Access
PhysioNet open
At a glance
Type
Dataset
DOI
Not reported
Licence
Not reported
Access
Not reported
Subjects
8
PPG sites
Finger
Setting
Lab
Wrist
Yes
Raw waveforms
Yes
Updated
Nov 13, 2026

Original description

Continuous monitoring of arterial blood pressure (BP) in non-clinical (ambulatory) settings is essential for a proper understanding of numerous health conditions. While conventional ambulatory BP devices exist, they are uncomfortable, bulky, and intrusive. In this work, we introduce a dataset of BP measurement using atomically-thin graphene electronic tattoos (GETs) and bioimpedance (Bio-Z) as measurement modality. The Bio-Z is measured from radial and ulnar arteries on the wrist. Afterward, a machine learning regression model is employed to relate the recorded bioimpedance to BP, yielding an effective beat-to-beat BP monitoring platform. In this database, we are sharing the raw time data for the 4-channel GET Bioimpedance signals with BP and PPG signals. The GETs are used to monitor arterial blood pressure from N=7 individuals for 300+ minutes each. A medical-grade BP monitoring device, Finapres NOVA, was used to measure the subject's control BP during the experiments. On average, each participant underwent 4±1 hours of continuous BP monitoring. Altogether, we performed on average ~2500±600 BP measurements per participant, which resulted in a total of 18667 datapoints.

Verbatim fromPhysioNet· Licence: Open Data Commons Attribution License v1.0

Continuous cuffless BP via graphene bioimpedance tattoos (PhysioNet): ChatPPG research summary card

Key numbers

8
Subjects
2
Reference labels
CUFF BP, BP
200 Hz
Released sampling rate
fingertip PPG 1250 Hz; Finapres PPG 75 Hz; wrist BioZ 1250 Hz; Finapres brachial BP 200 Hz

How it works

How Continuous cuffless BP via graphene bioimpedance tattoos (PhysioNet) works: Devices & body sites → Signals recorded → TasksDevices & body sites: Finapres NOVA (Finapres Medical Systems · Finger). PPG sites: Finger. Signals recorded: Continuous cuffless BP via graphene bioimpedance tattoos (PhysioNet), 8 subjects · 200 Hz, signals PPG, ABP, Bioimpedance. Tasks: Blood pressure.Devices & body sitesFinapres NOVA: Finapres Medical Systems · FingerFinapres NOVAFinapres Medical Systems · FingerPPG sites: FingerPPG sitesFingerSignals recordedContinuous cuffless BP via…8 subjects · 200 HzPPGABPBioimpedanceTasksBlood pressureBlood pressure

No model in the hub reports results on this dataset yet.

Sampling
fingertip PPG 1250 Hz; Finapres PPG 75 Hz; wrist BioZ 1250 Hz; Finapres brachial BP 200 Hz
Reference labels
cuff bp, bp
Device roles
Clinical reference (BP) · Reference PPG

Devices· 1

Full photo credits, sources and licences are on each device page.

FAQ

How many subjects are in Continuous cuffless BP via graphene bioimpedance tattoos?

Continuous cuffless BP via graphene bioimpedance tattoos has data from 8 subjects, as listed in its research record.

What signals does Continuous cuffless BP via graphene bioimpedance tattoos include?

Continuous cuffless BP via graphene bioimpedance tattoos includes PPG, continuous blood pressure and bioimpedance data. Sampling rate as recorded: fingertip PPG 1250 Hz; Finapres PPG 75 Hz; wrist BioZ 1250 Hz; Finapres brachial BP 200 Hz. Raw waveforms are included.

What can Continuous cuffless BP via graphene bioimpedance tattoos be used for?

Research tasks it supports: cuffless blood pressure estimation. Reference labels: cuff blood pressure and blood pressure.

How do I get Continuous cuffless BP via graphene bioimpedance tattoos, and what is its licence?

It is hosted on PhysioNet at https://physionet.org/content/bp-graphene-bioimpedance/1.0.0/. No licence is recorded for it here, so check the terms on the source page before you use it.

Cite

No citation metadata yet.

Cite the ChatPPG record

Cite the dated snapshot 2026-10 for a fixed, reproducible version. Please also cite the original publications listed above.

APA

ChatPPG. (2026). Continuous cuffless BP via graphene bioimpedance tattoos (PhysioNet): dataset record (Version 2026-10) [Data set]. ChatPPG Research Hub. https://chatppg.com/research/datasets/bp-graphene-bioimpedance

BibTeX
@misc{chatppg_dataset_bp_graphene_bioimpedance,
  author       = {{ChatPPG}},
  title        = {{Continuous cuffless BP via graphene bioimpedance tattoos (PhysioNet): dataset record}},
  year         = {2026},
  month        = nov,
  version      = {2026-10},
  howpublished = {\url{https://chatppg.com/research/datasets/bp-graphene-bioimpedance}},
  note         = {ChatPPG Research Hub, Snapshot 2026-10, https://chatppg.com/research/snapshots/2026-10}
}
CITATION.cff
cff-version: 1.2.0
message: "If you use this resource, please cite it as below."
type: dataset
title: "Continuous cuffless BP via graphene bioimpedance tattoos (PhysioNet): dataset record"
authors:
  - name: "ChatPPG"
url: "https://chatppg.com/research/datasets/bp-graphene-bioimpedance"
repository-artifact: "https://chatppg.com/research/snapshots/2026-10"
version: "2026-10"
date-released: "2026-11-13"

History

  1. Record updated