Paperdoi:10.1016/j.sleep.2026.109103

Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry

Venue listedDated Jun 29, 2026Added Nov 20, 2026

  • PT
  • CG
  • DL

Authors: Pasquale Tondo, Crescenzio Gallo, Donato Lacedonia

Sleep Medicine (2026), article 109103

TL;DR

DEPH expresses nocturnal hypoxic burden as a unitless ratio, desaturation area over the total area, so it works on plain overnight oximetry and outside OSA. On 1,000 recordings from patients with mixed chronic respiratory diseases it was compared with three existing hypoxic-burden definitions (fixed 100% and 90% baselines and a fully automated one) after standardizing them to be comparable.

  • Form factor: nocturnal pulse oximetry (finger, clinical)

Abstract

BackgroundNocturnal hypoxic burden (HB) has been described using multiple algorithmic definitions, each based on different assumptions regarding signal segmentation and baseline reference, in obstructive sleep apnea (OSA). However, existing approaches share several methodological limitations and lack a standardization. These metrics have been applied almost exclusively in OSA and only on polysomnographic recordings, rendering the resulting indices non-comparable across methods. To address these gaps, we introduce the Dynamic Evaluation of Peripheral Hypoxia (DEPH), a method applicable to nocturnal pulse-oximetry and across heterogeneous respiratory diseases.MethodsA retrospective analysis was conducted on 1000 consecutive nocturnal pulse-oximetry recordings from patients with heterogeneous chronic respiratory disorders referred for suspected nocturnal hypoxemia. DEPH was designed to express HB as a dimensionless measure through the ratio of two areas (desaturation area/global area). The performance of DEPH was compared with that of three other methods (HB100, fixed 100% SpO2 baseline; HB90, fixed 90% baseline; HBFA, fully automated) already used for HB determination, after standardizing the HB (sHB), so that the resulting indices were directly comparable.ResultsThe cohort had a mean age of 65.9 ± 13.1 years (60% male) and a mean BMI of 34.6 ± 9.0 kg m-2. Mean SpO2 was 90.0 ± 4.7%, nadir 75.3 ± 10.6%, SpO2stDev 2.8 ± 1.8% and T90 34.4 ± 33.9%, reflecting marked variability in oximetric patterns across individuals. The estimation of sHB was statistically different between the four methods used (sHBDEPH 4.1 ± 2.8%, sHBFA 2.4 ± 1.6%, sHB100 9.8 ± 3.9%, sHB90 1.9 ± 3.0%, p ConclusionsDEPH appears to provide a more complete representation of desaturation areas and hypoxic burden applicable to nocturnal pulse-oximetry across heterogeneous chronic respiratory diseases, while its standardization (sHB) offers a common scale on which existing HB methods can be directly compared. As a methodological exploration rather than a clinical validation, the approach requires further study in larger, external cohorts to establish its clinical and prognostic value.

Verbatim from Europe PMC (opens in a new tab) · Licence: cc by

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

SpO₂

Signals

Keywords

SpO₂Hypoxic BurdenNocturnal OximetryCOPDOSAMetric Design

How it works

How Method works: Setup → Method → TargetSetup: Signals (SpO2 (pulse oximetry)); Form factor (nocturnal pulse oximetry (finger, clinical)). Method: Method. Target: SpO₂.SetupSignals: SpO2 (pulse oximetry)R / IRSignalsSpO2 (pulse oximetry)Form factor: nocturnal pulse oximetry (finger, clinical)Form factornocturnal pulse oximetry (finger…MethodMethodTargetSpO₂O₂SpO₂

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Tondo, P., Gallo, C., & Lacedonia, D. (2026). Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry. Sleep Medicine, 109103. https://doi.org/10.1016/j.sleep.2026.109103
Tondo, Pasquale, Crescenzio Gallo, and Donato Lacedonia. 2026. "Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry." Sleep Medicine, 109103. https://doi.org/10.1016/j.sleep.2026.109103.
Tondo, P., Gallo, C. and Lacedonia, D. (2026) 'Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry', Sleep Medicine, p. 109103. doi: 10.1016/j.sleep.2026.109103.
Tondo, Pasquale, et al. "Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry." Sleep Medicine, 2026, p. 109103. https://doi.org/10.1016/j.sleep.2026.109103.
P. Tondo, C. Gallo, and D. Lacedonia, "Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry," Sleep Medicine, p. 109103, 2026, doi: 10.1016/j.sleep.2026.109103.
@article{tondo2026dynamic,
  title         = {{Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry}},
  author        = {Tondo, Pasquale and Gallo, Crescenzio and Lacedonia, Donato},
  year          = {2026},
  journal       = {Sleep Medicine},
  pages         = {109103},
  doi           = {10.1016/j.sleep.2026.109103}
}

Added to the ChatPPG research hub