Paperdoi:10.3389/fphys.2026.1956566
Differences in pulse oximetry saturation from sea level to high altitude among subjects with and without respiratory disease. A population-based, cross-sectional study
Frontiers in Physiology
TL;DR
PREPOCOL II, population-based cross-sectional study of adults >=40 y in Colombian cities from 18 to 3,030 m: 1,146 with chronic respiratory disease vs 4,613 controls. Altitude was the strongest SpO2 correlate (standardized beta -0.69 controls, -0.71 disease), then age and BMI; the per-altitude SpO2 drop was steeper with respiratory disease (B -1.15 vs -0.80), and the gap showed by ~1,500 m (median 97.0% vs 95.5%).
Abstract
Introduction
Oxygen saturation (SpO 2 ) is used to detect hypoxemia and guide oxygen therapy, but its interpretation varies with altitude, age, and lung disease. Although >500 million people live at ≥1,500 m, population-based data comparing SpO 2 across altitudes in adults with and without chronic respiratory disease are scarce. We aimed to compare SpO 2 between these groups from sea level to 3,030 m, identify factors associated with SpO 2 , and describe SpO 2 by altitude and age in adults without respiratory disease. We hypothesized that SpO 2 would be lower in participants with respiratory disease, with differences increasing with altitude.
Methods
PREPOCOL II is a population-based, cross-sectional study with a probabilistic, two-stage, clustered sampling design to estimate the prevalence and risk factors for respiratory disease among adults ≥40 years in Colombian cities at different altitudes (18-3030 m). All participants completed a standardized questionnaire, spirometry, and SpO 2 measurement. Participants with respiratory disease (RDP), including chronic obstructive pulmonary disease, asthma, chronic bronchitis, obstructive sleep apnea, and interstitial lung disease, were compared with controls using Mann-Whitney and Kruskal-Wallis tests, multivariable linear regression, and comparisons of altitude coefficients between groups.
Results
A total of 1146 RDP and 4613 controls were included. RDP were older, and had lower BMI and lung function. SpO 2 was lower in RDP than in controls at all altitudes and decreased in both groups as altitude and age increased (p2 (standardized β −0.69 in controls and −0.71 in RDP), followed by age and BMI (and FEV 1 in RDP). The decrease in SpO 2 per unit of altitude was larger in RDP (B −1.15 vs. −0.80; difference p Conclusion
Among lifelong residents living at altitudes from sea level to 3,030 m, SpO 2 was lower in RDP than in controls. SpO 2 decreased with altitude and age in both groups, with altitude being the variable most strongly associated with SpO 2 . SpO 2 values should be interpreted in relation to specific altitude and age. In RDP, the lower SpO 2 was most evident at altitudes of ~1,500 m and above.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
Gonzalez-Garcia, M., Torres-Duque, C. A., Aguirre-Franco, C., Alí-Munive, A., Proaños, N. J., Perez, C., & Casas-Herrera, A. (2026). Differences in pulse oximetry saturation from sea level to high altitude among subjects with and without respiratory disease. A population-based, cross-sectional study. Frontiers in Physiology. https://doi.org/10.3389/fphys.2026.1956566
Gonzalez-Garcia, Mauricio, Carlos A. Torres-Duque, Carlos Aguirre-Franco, Abraham Alí-Munive, Nadia Juliana Proaños, Carolina Perez, and Alejandro Casas-Herrera. 2026. "Differences in pulse oximetry saturation from sea level to high altitude among subjects with and without respiratory disease. A population-based, cross-sectional study." Frontiers in Physiology. https://doi.org/10.3389/fphys.2026.1956566.
Gonzalez-Garcia, M., Torres-Duque, C. A., Aguirre-Franco, C., Alí-Munive, A., Proaños, N. J., Perez, C. and Casas-Herrera, A. (2026) 'Differences in pulse oximetry saturation from sea level to high altitude among subjects with and without respiratory disease. A population-based, cross-sectional study', Frontiers in Physiology. doi: 10.3389/fphys.2026.1956566.
Gonzalez-Garcia, Mauricio, et al. "Differences in pulse oximetry saturation from sea level to high altitude among subjects with and without respiratory disease. A population-based, cross-sectional study." Frontiers in Physiology, 2026. https://doi.org/10.3389/fphys.2026.1956566.
M. Gonzalez-Garcia et al., "Differences in pulse oximetry saturation from sea level to high altitude among subjects with and without respiratory disease. A population-based, cross-sectional study," Frontiers in Physiology, 2026, doi: 10.3389/fphys.2026.1956566.
@article{gonzalezgarcia2026differences,
title = {{Differences in pulse oximetry saturation from sea level to high altitude among subjects with and without respiratory disease. A population-based, cross-sectional study}},
author = {Gonzalez-Garcia, Mauricio and Torres-Duque, Carlos A. and Aguirre-Franco, Carlos and Alí-Munive, Abraham and Proaños, Nadia Juliana and Perez, Carolina and Casas-Herrera, Alejandro},
year = {2026},
journal = {Frontiers in Physiology},
doi = {10.3389/fphys.2026.1956566}
}Added to the ChatPPG research hub