TL;DR

Evaluates the Cosinuss °Temp in-ear thermometer for monitoring ear-canal temperature in 49 workers in the lab and during real outdoor work, against hospital infrared ear thermometry. It was inaccurate without an individual correction factor; with correction it was reliable at rest but not outdoors or under helmets and hearing protection.

Abstract

Aimed at preventing heat strain, health problems, and absenteeism among workers with physically demanding occupations, a continuous, accurate, non-invasive measuring system may help such workers monitor their body (core) temperature. The aim of this study is to evaluate the accuracy and explore the usability of the wearable non-invasive Cosinuss° °Temp thermometer. Ear canal temperature was monitored in 49 workers in real-life working conditions. After individual correction, the results of the laboratory and field study revealed high correlations compared to ear canal infrared thermometry for hospital use. After performance of the real-life working tasks, this correlation was found to be moderate. It was also observed that the ambient environmental outdoor conditions and personal protective clothing influenced the accuracy and resulted in unrealistic ear canal temperature outliers. It was found that the Cosinuss° °Temp thermometer did not result in significant interference during work. Therefore, it was concluded that, without a correction factor, the Cosinuss° °Temp thermometer is inaccurate. Nevertheless, with a correction factor, the reliability of this wearable ear canal thermometer was confirmed at rest, but not in outdoor working conditions or while wearing a helmet or hearing protection equipment.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Core Body Temperature

How it works

How Method works: Setup → Method → TargetSetup: Signals (in-ear temperature (Cosinuss °Temp)). Method: Method.SetupSignals: in-ear temperature (Cosinuss °Temp)Signalsin-ear temperature (Cosinuss °Temp)MethodMethod

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Roossien, C., Hodselmans, A., Heus, R., Reneman, M., et al. (2021). Evaluation of a wearable non-invasive thermometer for monitoring ear canal temperature during physically demanding (outdoor) work. Int J Environ Res Public Health , 2021, 18(9), 4896. https://doi.org/10.3390/ijerph18094896
Roossien, CC, AP Hodselmans, R Heus, and MF Reneman, et al. 2021. "Evaluation of a wearable non-invasive thermometer for monitoring ear canal temperature during physically demanding (outdoor) work." Int J Environ Res Public Health , 2021 18 (9): 4896. https://doi.org/10.3390/ijerph18094896.
Roossien, C., Hodselmans, A., Heus, R. and Reneman, M. et al. (2021) 'Evaluation of a wearable non-invasive thermometer for monitoring ear canal temperature during physically demanding (outdoor) work', Int J Environ Res Public Health , 2021, 18(9), p. 4896. doi: 10.3390/ijerph18094896.
Roossien, CC, et al. "Evaluation of a wearable non-invasive thermometer for monitoring ear canal temperature during physically demanding (outdoor) work." Int J Environ Res Public Health , 2021, vol. 18, no. 9, 2021, p. 4896. https://doi.org/10.3390/ijerph18094896.
C. Roossien et al., "Evaluation of a wearable non-invasive thermometer for monitoring ear canal temperature during physically demanding (outdoor) work," Int J Environ Res Public Health , 2021, vol. 18, no. 9, p. 4896, 2021, doi: 10.3390/ijerph18094896.
@article{roossien2021evaluation,
  title         = {{Evaluation of a wearable non-invasive thermometer for monitoring ear canal temperature during physically demanding (outdoor) work}},
  author        = {Roossien, CC and Hodselmans, AP and Heus, R. and Reneman, MF and others},
  year          = {2021},
  journal       = {Int J Environ Res Public Health , 2021},
  volume        = {18},
  number        = {9},
  pages         = {4896},
  doi           = {10.3390/ijerph18094896}
}

Added to the ChatPPG research hub