Paperdoi:10.1088/1361-6579/acf991
Individualized monitoring of heat illness risk: adaptive physiological strain index (aPSI)
Physiological Measurement, 2023
TL;DR
Proposes the adaptive physiological strain index (aPSI), which adjusts the critical core temperature of the standard physiological strain index using the core-to-skin temperature gradient. In elite athletes running an 8 km time trial and soldiers marching 2 km in encapsulating protective equipment, end-of-exercise PSI differed widely between the groups (11.4 versus 7.6), while aPSI gave similar values (9.9 versus 9.0), better matching their shared very high heat strain.
Abstract
Objective . Exercise-heat strain estimation approaches often involve combinations of body core temperature (Tcore), skin temperature (Tsk) and heart rate (HR). A successful existing measure is the ‘Physiological Strain Index’ (PSI), which combines HR and Tcore values to estimate strain. However, depending on variables such as aerobic fitness and clothing, the equation’s ‘maximal/critical’ Tcore must be changed to accurately represent the strain, in part because high Tsk (small Tcore−Tsk) can increase cardiovascular strain and thereby negatively affect performance. Here, an ‘adaptive PSI’ (aPSI) is presented where the original PSI Tcore critical value is ‘adapted’ dynamically by the delta between Tcore and Tsk. Approach . PSI and aPSI were computed for athletes (ELITE, N = 11 male and 8 female, 8 km time-trial) and soldiers in fully encapsulating personal protective equipment (PPE, N = 8 male, 2 km approach-march). While these were dissimilar events, it was anticipated given that the clothing and work rates would elicit similar very-high exercise-heat strain values. Main results . Mean end HR values were similar (∼180 beats min −1 ) with higher Tcore = 40.1 ± 0.4 °C for ELITE versus PPE 38.4 ± 0.6 °C ( P P p > 0.05) indicating a ‘very high’ level of exercise-heat strain for both conditions. Significance . A simple adaptation of the PSI equation, which accounts for differences in Tcore-to-Tsk gradients, provides a physiological approach to dynamically adapt PSI to provide a more accurate index of exercise-heat strain under very different working conditions.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://publishingsupport.iopscience.iop.org/iop-standard/v1
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Signals
Keywords
How it works
Cite this paper
Buller, M., Atkinson, E., Driver, K., Tharion, W., et al. (2023). Individualized monitoring of heat illness risk: adaptive physiological strain index (aPSI). Physiological Measurement, 2023. https://doi.org/10.1088/1361-6579/acf991
Buller, MJ, EY Atkinson, KA Driver, and WJ Tharion, et al. 2023. "Individualized monitoring of heat illness risk: adaptive physiological strain index (aPSI)." Physiological Measurement, 2023. https://doi.org/10.1088/1361-6579/acf991.
Buller, M., Atkinson, E., Driver, K. and Tharion, W. et al. (2023) 'Individualized monitoring of heat illness risk: adaptive physiological strain index (aPSI)', Physiological Measurement, 2023. doi: 10.1088/1361-6579/acf991.
Buller, MJ, et al. "Individualized monitoring of heat illness risk: adaptive physiological strain index (aPSI)." Physiological Measurement, 2023, 2023. https://doi.org/10.1088/1361-6579/acf991.
M. Buller et al., "Individualized monitoring of heat illness risk: adaptive physiological strain index (aPSI)," Physiological Measurement, 2023, 2023, doi: 10.1088/1361-6579/acf991.
@article{buller2023individualized,
title = {{Individualized monitoring of heat illness risk: adaptive physiological strain index (aPSI)}},
author = {Buller, MJ and Atkinson, EY and Driver, KA and Tharion, WJ and others},
year = {2023},
journal = {Physiological Measurement, 2023},
doi = {10.1088/1361-6579/acf991}
}Record updated
Added to the ChatPPG research hub