Paperdoi:10.64898/2026.04.09.26350266

Wearable sleep staging performance declines with sleep apnea severity and is sensitive to training-set composition in very severe sleep apnea

Preprint2026Added Nov 15, 2026

  • SO
  • MK
  • TN
  • SF
  • NO
  • TY
  • YT
  • TO

Authors: Sho Ogaki, Michiru Kaneda, Tomoyuki Nohara, Syuhei Fujita, Naoshi Osako, Tomoko Yagi, Yasuhiro Tomita, Takanori Ogata

medRxiv (2026-04-10)

TL;DR

Deep-learning sleep staging from wrist PPG-derived RR intervals + accelerometry on 552 nights (318 sleep-lab, 234 hospital; 62 with AHI ≥ 50). 4-fold CV: 5-stage kappa 0.586 (sleep lab) vs 0.446 (hospital); 4-stage 0.632 vs 0.525. In the hospital set kappa falls with AHI severity (median ~0.2 lower in very severe vs mild).

  • Form factor: wrist

Abstract

We aimed to evaluate wearable sleep staging across sleep apnea severity, including very severe sleep apnea defined as an apnea–hypopnea index (AHI) ≥ 50 events/h, and to assess how training-set composition affects performance in this subgroup. We analyzed 552 overnight recordings: 318 from the Sleep Lab Dataset and 234 from the Hospital Dataset, of which 26.5% (N=62) had very severe sleep apnea. A deep learning model performed sleep staging from photoplethysmography-derived RR intervals and accelerometry recorded by a wrist-worn device. Baseline performance was assessed by 4-fold cross-validation using randomly partitioned folds from the combined datasets. We examined night-level associations with AHI severity. We also compared the baseline model with an ablation model trained on the same number of recordings but with all Sleep Lab Dataset recordings and lower-AHI Hospital Dataset recordings, evaluating both in the very severe subgroup. For 5-stage classification, Cohen’s kappa was 0.586 in the Sleep Lab Dataset and 0.446 in the Hospital Dataset. Under 4-stage staging, the gap narrowed, with kappa values of 0.632 and 0.525, respectively. In the Hospital Dataset, kappa declined with AHI severity, with median kappa differing by about 0.2 between mild and very severe groups. In the very severe subgroup, kappa decreased from 0.365 (baseline) to 0.303 (ablation). Wearable sleep staging performance tended to decline across greater sleep apnea severity. Clinical utility may benefit from training data spanning the target severity spectrum and staging granularity matched to the intended use.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: http://creativecommons.org/licenses/by-nc-nd/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Sleep staging

Signals

Keywords

ACCSleep StagingOSAAHIDomain ShiftTraining Composition

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG (RR), ACC); Form factor (wrist). Method: Method. Target: Sleep staging.SetupSignals: PPG (RR), ACCSignalsPPG (RR), ACCForm factor: wristForm factorwristMethodMethodTargetSleep stagingSleep staging

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Ogaki, S., Kaneda, M., Nohara, T., Fujita, S., Osako, N., Yagi, T., Tomita, Y., & Ogata, T. (2026). Wearable sleep staging performance declines with sleep apnea severity and is sensitive to training-set composition in very severe sleep apnea. medRxiv. https://doi.org/10.64898/2026.04.09.26350266
Ogaki, Sho, Michiru Kaneda, Tomoyuki Nohara, Syuhei Fujita, Naoshi Osako, Tomoko Yagi, Yasuhiro Tomita, and Takanori Ogata. 2026. "Wearable sleep staging performance declines with sleep apnea severity and is sensitive to training-set composition in very severe sleep apnea." medRxiv. https://doi.org/10.64898/2026.04.09.26350266.
Ogaki, S., Kaneda, M., Nohara, T., Fujita, S., Osako, N., Yagi, T., Tomita, Y. and Ogata, T. (2026) 'Wearable sleep staging performance declines with sleep apnea severity and is sensitive to training-set composition in very severe sleep apnea', medRxiv. doi: 10.64898/2026.04.09.26350266.
Ogaki, Sho, et al. "Wearable sleep staging performance declines with sleep apnea severity and is sensitive to training-set composition in very severe sleep apnea." medRxiv, 2026. https://doi.org/10.64898/2026.04.09.26350266.
S. Ogaki et al., "Wearable sleep staging performance declines with sleep apnea severity and is sensitive to training-set composition in very severe sleep apnea," medRxiv, 2026, doi: 10.64898/2026.04.09.26350266.
@misc{ogaki2026wearable,
  title         = {{Wearable sleep staging performance declines with sleep apnea severity and is sensitive to training-set composition in very severe sleep apnea}},
  author        = {Ogaki, Sho and Kaneda, Michiru and Nohara, Tomoyuki and Fujita, Syuhei and Osako, Naoshi and Yagi, Tomoko and Tomita, Yasuhiro and Ogata, Takanori},
  year          = {2026},
  howpublished  = {medRxiv},
  doi           = {10.64898/2026.04.09.26350266}
}

Added to the ChatPPG research hub