Paperdoi:10.1016/j.jtherbio.2025.104241

Validity of the CORE wearable sensor during constant-load cycling exercise in the heat

Venue listed2025Added Nov 22, 2026

  • BM
  • JA
  • AL

Authors: BC McLaughlin, JT Aguilera, AC D'Lugos

Journal of Thermal Biology, 2025

TL;DR

Validity of the CORE wearable sensor (chest heat flux and skin temperature) against a rectal probe in 24 adults (13 men, 11 women) cycling for 60 minutes at 60% of maximal aerobic power in 35.9 °C heat. Overall bias was +0.15 ± 0.43 °C, with +0.31 and +0.36 °C in the third and fourth quarters of exercise. CORE skin temperature over-read by 1.28 °C, and subcutaneous fat was correlated with bias.

Abstract

Heat exposure is an increasing threat to human health and accurately monitoring core body temperature is vital to avoiding heat-related illnesses during exercise and outdoor occupations. Recently, a wearable device (CORETM) was developed to non-invasively estimate core body temperature (TC). The purpose of this study was to determine the validity of the CORE sensor and identify subcutaneous fat as a potential contributor to the device's bias. Twenty-four healthy males (n = 13) and females (n = 11) completed 60 min of cycling exercise at 60 % of their maximum aerobic power output (166 ± 46.5 W) in the heat (35.9 °C & 20.7 % relative humidity). During exercise, TC and skin temperature (TSK) measures from the CORE sensor were compared to rectal probe and skin surface probe, respectively. Midaxillary subcutaneous fat thickness (MSFT) at the site of the CORE sensor was measured via ultrasonography. Throughout the entire exercise bout, the CORE displayed a non-statistically significant overestimation of TC (0.15 ± 0.43 °C, p = 0.057). However, CORE significantly overestimated TC during the third (0.31 ± 0.43 °C, p = 0.002) and fourth (0.36 ± 0.45 °C, p = 0.004) quarters of exercise. CORE also significantly overestimated TSK (1.28 ± 0.96 °C, p C (overestimation by CORE) during the third (r = 0.438, p = 0.032) and fourth (r = 0.482, p = 0.017) quarters of exercise. In conclusion, compared to rectal temperature, the CORE sensor overestimated TC during constant-load exercise in a hot environment. Overestimated TSK and local subcutaneous fat may be potential contributors to bias in the CORE sensor's TC estimation.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Models

How it works

How greenTEG CALERA / CORE core-body-temperature algorithm (heat flux + skin temperature + HR) works: Setup → Method → TargetSetup: Signals (chest heat flux + skin temperature (CORE)). Method: greenTEG CALERA / CORE core-body-temperature algorithm (heat flux + skin temperature + HR).SetupSignals: chest heat flux + skin temperature (CORE)Signalschest heat flux + skin temperature…MethodgreenTEG CALERA / CORE…

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

McLaughlin, B., Aguilera, J., D'Lugos, A., et al. (2025). Validity of the CORE wearable sensor during constant-load cycling exercise in the heat. Journal of Thermal Biology, 2025. https://doi.org/10.1016/j.jtherbio.2025.104241
McLaughlin, BC, JT Aguilera, and AC D'Lugos, et al. 2025. "Validity of the CORE wearable sensor during constant-load cycling exercise in the heat." Journal of Thermal Biology, 2025. https://doi.org/10.1016/j.jtherbio.2025.104241.
McLaughlin, B., Aguilera, J. and D'Lugos, A. et al. (2025) 'Validity of the CORE wearable sensor during constant-load cycling exercise in the heat', Journal of Thermal Biology, 2025. doi: 10.1016/j.jtherbio.2025.104241.
McLaughlin, BC, et al. "Validity of the CORE wearable sensor during constant-load cycling exercise in the heat." Journal of Thermal Biology, 2025, 2025. https://doi.org/10.1016/j.jtherbio.2025.104241.
B. McLaughlin et al., "Validity of the CORE wearable sensor during constant-load cycling exercise in the heat," Journal of Thermal Biology, 2025, 2025, doi: 10.1016/j.jtherbio.2025.104241.
@article{mclaughlin2025validity,
  title         = {{Validity of the CORE wearable sensor during constant-load cycling exercise in the heat}},
  author        = {McLaughlin, BC and Aguilera, JT and D'Lugos, AC and others},
  year          = {2025},
  journal       = {Journal of Thermal Biology, 2025},
  doi           = {10.1016/j.jtherbio.2025.104241}
}

Record updated