Paperdoi:10.3390/bioengineering13111388

Efficient and Enhanced Signal Quality Assessment for EDA Wearables (unsupervised-pretrained lightweight EDA SQI; EDABE AUC 0.851, zero-shot wrist E4 0.740, 3.9 MFLOPs)

Venue listed2026Added Nov 19, 2026

  • LL
  • LE
  • OC
  • NH
  • MG

Authors: Luoluo Liu, Linda M. Eerikäinen, Octavian Cota, Nicholas Huang, Mark van Gastel

Bioengineering (MDPI) 13(11):1388, 2026-11-19

TL;DR

Lightweight signal quality index for electrodermal activity, pretrained with unsupervised denoising and forecasting and then fine-tuned on a public expert-labelled set. It reached mean ROC-AUC 0.851 and AUPRC 0.494 on EDABE, and 0.740 zero-shot on wrist Empatica E4 data recorded during real driving (AffectiveROAD) although training used finger-worn data, at 3.9 MFLOPs per inference.

  • Form factor: finger (training) → wrist Empatica E4 (zero-shot)

Abstract

Electrodermal activity (EDA) is a widely used marker of sympathetic arousal and stress, in both daily-life and clinical monitoring, but EDA signals from wearable devices are frequently degraded by artifacts, and expert-labeled data for quality assessment are scarce. We present a lightweight EDA signal quality index (SQI) system that uses unsupervised pre-training to reduce reliance on labeled data. The model is first pre-trained on unsupervised denoising and forecasting tasks, then fine-tuned using a publicly available expert-labeled dataset. On the EDABE benchmark, our method achieves a mean ROC-AUC of 0.851 and a mean AUPRC of 0.494, improvements of 8% and 18.5%, respectively, over the strongest baseline. The model also generalizes across devices, body locations, and types of motion: applied zero-shot to AffectiveROAD, wrist-worn Empatica E4 recordings from real-world driving (whereas training used finger-worn sensors), it achieves a ROC-AUC of 0.740, a 7.9% improvement over the same network trained from scratch, using high wrist acceleration as the reference for motion artifacts. The model requires 3.9 MFLOPs per inference. These results show that unsupervised pre-training improves performance, enabling scalable, low-power EDA quality assessment for continuous wearable monitoring.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Signal qualitySignal denoising

Signals

Keywords

Signal QualitySQISelf SupervisedPretrainingMotion ArtifactEdgeAffect

How it works

How Method works: Setup → Method → TargetSetup: Signals (EDA, accel (motion reference)); Form factor (finger (training) → wrist Empatica E4 (zero-shot)). Method: Method. Target: Signal quality; Signal denoising.SetupSignals: EDA, accel (motion reference)SignalsEDA, accel (motion reference)Form factor: finger (training) → wrist Empatica E4 (zero-shot)Form factorfinger (training) → wrist Empatica E4…MethodMethodTargetSignal qualitySignal qualitySignal denoisingSignal denoising

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Liu, L., Eerikäinen, L. M., Cota, O., Huang, N., & van Gastel, M. (2026). Efficient and Enhanced Signal Quality Assessment for EDA Wearables (unsupervised-pretrained lightweight EDA SQI; EDABE AUC 0.851, zero-shot wrist E4 0.740, 3.9 MFLOPs). Bioengineering, 13(11), 1388. https://doi.org/10.3390/bioengineering13111388
Liu, Luoluo, Linda M. Eerikäinen, Octavian Cota, Nicholas Huang, and Mark van Gastel. 2026. "Efficient and Enhanced Signal Quality Assessment for EDA Wearables (unsupervised-pretrained lightweight EDA SQI; EDABE AUC 0.851, zero-shot wrist E4 0.740, 3.9 MFLOPs)." Bioengineering 13 (11): 1388. https://doi.org/10.3390/bioengineering13111388.
Liu, L., Eerikäinen, L. M., Cota, O., Huang, N. and van Gastel, M. (2026) 'Efficient and Enhanced Signal Quality Assessment for EDA Wearables (unsupervised-pretrained lightweight EDA SQI; EDABE AUC 0.851, zero-shot wrist E4 0.740, 3.9 MFLOPs)', Bioengineering, 13(11), p. 1388. doi: 10.3390/bioengineering13111388.
Liu, Luoluo, et al. "Efficient and Enhanced Signal Quality Assessment for EDA Wearables (unsupervised-pretrained lightweight EDA SQI; EDABE AUC 0.851, zero-shot wrist E4 0.740, 3.9 MFLOPs)." Bioengineering, vol. 13, no. 11, 2026, p. 1388. https://doi.org/10.3390/bioengineering13111388.
L. Liu, L. M. Eerikäinen, O. Cota, N. Huang, and M. van Gastel, "Efficient and Enhanced Signal Quality Assessment for EDA Wearables (unsupervised-pretrained lightweight EDA SQI; EDABE AUC 0.851, zero-shot wrist E4 0.740, 3.9 MFLOPs)," Bioengineering, vol. 13, no. 11, p. 1388, 2026, doi: 10.3390/bioengineering13111388.
@article{liu2026efficient,
  title         = {{Efficient and Enhanced Signal Quality Assessment for EDA Wearables (unsupervised-pretrained lightweight EDA SQI; EDABE AUC 0.851, zero-shot wrist E4 0.740, 3.9 MFLOPs)}},
  author        = {Liu, Luoluo and Eerikäinen, Linda M. and Cota, Octavian and Huang, Nicholas and van Gastel, Mark},
  year          = {2026},
  journal       = {Bioengineering},
  volume        = {13},
  number        = {11},
  pages         = {1388},
  publisher     = {MDPI},
  doi           = {10.3390/bioengineering13111388}
}

Added to the ChatPPG research hub