Paperdoi:10.3390/s26092674

From PPG to Blood Pressure at the Edge: Quantization-Aware Architecture Selection and On-MCU Validation

Venue listed2026Added Oct 11, 2026

  • EL
  • EL
  • FB

Authors: Elisabetta Leogrande, Emanuele De Luca, Francesco Dell’Olio (Polytechnic University of Bari)

Sensors (MDPI) 26(9):2674

TL;DR

Benchmarks several 1D CNNs for SBP/DBP from single-channel PPG jointly on error, footprint and INT8 quantization robustness. Float accuracy poorly predicts deployability: some light CNNs drift after INT8, while a compact residual 1D CNN keeps near-identical error. Deployed on an STM32N6 MCU with real-time inference and low bias.

  • Form factor: any

Abstract

Blood pressure is a central marker of cardiovascular risk, but continuous monitoring remains difficult because cuff-based measurements are intermittent and uncomfortable. Photoplethysmography (PPG) is already ubiquitous in wearables and can, in principle, enable cuffless blood pressure estimation from a single optical signal. However, many deep learning approaches that perform well in floating-point are impractical for microcontroller-class devices, where memory budgets, latency, and integer-only arithmetic constrain what can be deployed. A key open question is which neural architectures retain accuracy after full-integer quantization, rather than only under desktop inference. Here, we show an end-to-end, microcontroller-oriented evaluation framework that benchmarks multiple 1D convolutional models for cuffless systolic and diastolic pressure estimation from single-channel PPG, jointly optimizing estimation error, model footprint, and quantization robustness. We find that floating-point accuracy alone is a poor predictor of deployability: some lightweight CNNs exhibit substantial performance drift after INT8 conversion, whereas a compact residual 1D CNN preserves its predictions with near-identical error statistics after integer quantization. We then deploy the selected integer-only model on an STM32N6 microcontroller using an industrial toolchain and confirm that on-device inference maintains low bias and limited error dispersion while meeting real-time constraints for continuous operation. These results highlight architecture-dependent quantization stability as a critical design dimension for sensor-edge intelligence and support the feasibility of fully on-device cuffless blood pressure monitoring without multimodal sensing or cloud processing.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Blood pressure

Signals

Keywords

cuffless-BPedgequantizationMCUINT8

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG); Form factor (any). Method: Method. Target: Blood pressure.SetupSignals: PPGSignalsPPGForm factor: anyForm factoranyMethodMethodTargetBlood pressureBlood pressure

Cite this paper

APA

Leogrande, E., De Luca, E., & Dell’Olio, F. (2026). From PPG to Blood Pressure at the Edge: Quantization-Aware Architecture Selection and On-MCU Validation. Sensors. https://doi.org/10.3390/s26092674

BibTeX

@article{leogrande2026from,
  title         = {{From PPG to Blood Pressure at the Edge: Quantization-Aware Architecture Selection and On-MCU Validation}},
  author        = {Leogrande, Elisabetta and De Luca, Emanuele and Dell’Olio, Francesco},
  year          = {2026},
  journal       = {Sensors},
  doi           = {10.3390/s26092674}
}

Built from the hub record. Check it against the publisher before submitting.

Added to the ChatPPG research hub