Paperdoi:10.3390/s26092674
From PPG to Blood Pressure at the Edge: Quantization-Aware Architecture Selection and On-MCU Validation
Sensors (MDPI) 26(9):2674
TL;DR
Benchmarks several 1D CNNs for SBP/DBP from single-channel PPG jointly on error, footprint and INT8 quantization robustness. Float accuracy poorly predicts deployability: some light CNNs drift after INT8, while a compact residual 1D CNN keeps near-identical error. Deployed on an STM32N6 MCU with real-time inference and low bias.
- Form factor: any
Abstract
Blood pressure is a central marker of cardiovascular risk, but continuous monitoring remains difficult because cuff-based measurements are intermittent and uncomfortable. Photoplethysmography (PPG) is already ubiquitous in wearables and can, in principle, enable cuffless blood pressure estimation from a single optical signal. However, many deep learning approaches that perform well in floating-point are impractical for microcontroller-class devices, where memory budgets, latency, and integer-only arithmetic constrain what can be deployed. A key open question is which neural architectures retain accuracy after full-integer quantization, rather than only under desktop inference. Here, we show an end-to-end, microcontroller-oriented evaluation framework that benchmarks multiple 1D convolutional models for cuffless systolic and diastolic pressure estimation from single-channel PPG, jointly optimizing estimation error, model footprint, and quantization robustness. We find that floating-point accuracy alone is a poor predictor of deployability: some lightweight CNNs exhibit substantial performance drift after INT8 conversion, whereas a compact residual 1D CNN preserves its predictions with near-identical error statistics after integer quantization. We then deploy the selected integer-only model on an STM32N6 microcontroller using an industrial toolchain and confirm that on-device inference maintains low bias and limited error dispersion while meeting real-time constraints for continuous operation. These results highlight architecture-dependent quantization stability as a critical design dimension for sensor-edge intelligence and support the feasibility of fully on-device cuffless blood pressure monitoring without multimodal sensing or cloud processing.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
APA
Leogrande, E., De Luca, E., & Dell’Olio, F. (2026). From PPG to Blood Pressure at the Edge: Quantization-Aware Architecture Selection and On-MCU Validation. Sensors. https://doi.org/10.3390/s26092674
BibTeX
@article{leogrande2026from,
title = {{From PPG to Blood Pressure at the Edge: Quantization-Aware Architecture Selection and On-MCU Validation}},
author = {Leogrande, Elisabetta and De Luca, Emanuele and Dell’Olio, Francesco},
year = {2026},
journal = {Sensors},
doi = {10.3390/s26092674}
}Built from the hub record. Check it against the publisher before submitting.
Added to the ChatPPG research hub