PaperarXiv:2610.37132
Robust PPG-Exclusive Heart Rate Estimation During Maximal Exercise Using Population-Based Priors
Computing in Cardiology 2026 (53rd CinC, Madrid, 2026-09-20..23); arXiv 2610.37132 (2026-10-27)
TL;DR
HR priors are built from ground-truth ECG HR curves of the training subjects (leave-one-subject-out). Normalised HR curves are aligned with dynamic time warping (DTW) and averaged into a barycenter. For each test subject the PPG power spectral density is combined with the prior into a "posterior PSD", candidate HR trajectories are ranked by heuristic search, and the most likely path is chosen.
Abstract
PPG is the main technology for wearable heart rate (HR) monitoring. However, motion artifacts during intense physical activity reduce its reliability due to spectral overlap with the cardiac signal. This study investigates whether severely contaminated PPG signals can yield reliable HR estimates without auxiliary sensors by leveraging prior knowledge of HR dynamics. We acquired simultaneous PPG and ECG signals from 21 subjects during a maximal cycloergometer test. Using Leave-One-Subject-Out cross-validation, we built HR evolution priors from the ground-truth ECG and applied Dynamic Time Warping (DTW) to align normalized HR curves and estimate a barycenter average. DTW aligns normalized HR curves with minimal error across all subjects, validating robust population-based priors. For each test subject, we combined the PPG Power Spectral Density (PSD) with the prior distribution to generate a "posterior PSD". We identified and ranked candidate HR trajectories using heuristic search within the "posterior PSD" and selected the most likely path. Our approach reduced mean absolute error (MAE) in BPM relative to the ground-truth ECG by a median of 63.3% (IQR: 47.3%-74.6%) compared to a PPG+accelerometer benchmark. These results show that physiological priors and DTW-based alignment enable robust, PPG-exclusive HR monitoring during high-intensity exercise.
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards · 1
All leaderboards| Leaderboard | Method | Result | Rank |
|---|---|---|---|
| MAX-HIE-PPG-PRIOR-CYCLOERGOMETER MAE (BPM) (Median)Heart rate estimation | PPG-Prior Top-Traj | 8.88MAE (BPM), lower is better | #1 of 1 |
1 row is credited to this paper. Ranks apply within each leaderboard only, as reported by the source.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
De Giovanni, E., Urteaga, I., Croci, M., & Teijeiro, T. (2026). Robust PPG-Exclusive Heart Rate Estimation During Maximal Exercise Using Population-Based Priors. Computing in Cardiology 2026. https://arxiv.org/abs/2610.37132
De Giovanni, Elisabetta, Iñigo Urteaga, Matteo Croci, and Tomas Teijeiro. 2026. "Robust PPG-Exclusive Heart Rate Estimation During Maximal Exercise Using Population-Based Priors." Computing in Cardiology 2026. https://arxiv.org/abs/2610.37132.
De Giovanni, E., Urteaga, I., Croci, M. and Teijeiro, T. (2026) 'Robust PPG-Exclusive Heart Rate Estimation During Maximal Exercise Using Population-Based Priors', Computing in Cardiology 2026. Available at: https://arxiv.org/abs/2610.37132
De Giovanni, Elisabetta, et al. "Robust PPG-Exclusive Heart Rate Estimation During Maximal Exercise Using Population-Based Priors." Computing in Cardiology 2026, 2026. https://arxiv.org/abs/2610.37132.
E. De Giovanni, I. Urteaga, M. Croci, and T. Teijeiro, "Robust PPG-Exclusive Heart Rate Estimation During Maximal Exercise Using Population-Based Priors," Computing in Cardiology 2026, 2026, [Online]. Available: https://arxiv.org/abs/2610.37132.
@article{giovanni2026robust,
title = {{Robust PPG-Exclusive Heart Rate Estimation During Maximal Exercise Using Population-Based Priors}},
author = {De Giovanni, Elisabetta and Urteaga, Iñigo and Croci, Matteo and Teijeiro, Tomas},
year = {2026},
journal = {Computing in Cardiology 2026},
eprint = {2610.37132},
archivePrefix = {arXiv}
}Added to the ChatPPG research hub