PaperarXiv:2608.02946
Sedentary Behavior Classification for Wearable Sensors with a CNN-BiLSTM Model (CHAP hip→wrist transfer on iWatch)
arXiv cs.LG, v2 updated 2026-11-03 (v1 2026-08-03)
TL;DR
Task: sitting vs non-sitting from triaxial accelerometer; CHAP = CNN encoder per 10 s window + BiLSTM over 7 min (42 windows @ 10 Hz). Hip zero-shot (pretrained CHAP): test balanced accuracy 88.74%; finetuning adds little on hip. Wrist zero-shot drops to 71.83%; wrist finetune recovers 82.56% bal-acc (vs ViT-Small from scratch 79.39%).
- Form factor: hip and wrist ActiGraph GT3X+
Abstract
Accurate detection of sedentary behavior is important for studying health risks related to prolonged sitting, but posture-based classification remains challenging with wearable sensors, especially at the wrist. We study whether a deep learning model trained on hip-worn accelerometer data can transfer to wrist-worn accelerometer data for sitting versus non-sitting classification. We use CHAP, a CNN-BiLSTM model originally developed for hip accelerometers, and evaluate its zero-shot performance on wrist data as well as its adaptation through finetuning with varying amounts of labeled wrist data. Experiments are conducted on the iWatch dataset with ground-truth posture labels derived from wearable cameras. The hip-trained model performs strongly on hip data without retraining, but accuracy drops on wrist data due to sensor placement shift. Finetuning CHAP provides consistent advantages over transformer models trained from scratch. These findings suggest that hip-based pretraining provides a useful starting point for wrist deployment, while highlighting the need for wrist-specific adaptation to handle higher signal variability.
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
Chen, Y., Shi, W., Zablocki, R., Kumar, A., Carlson, J. A., Hartman, S. J., Greenwood-Hickman, M. A., Hibbing, P. R., Jankowska, M., Yang, J., Zou, J., Kumar, A., & Natarajan, L. (2026). Sedentary Behavior Classification for Wearable Sensors with a CNN-BiLSTM Model (CHAP hip→wrist transfer on iWatch). arXiv cs.LG, v2 updated. https://arxiv.org/abs/2608.02946
Chen, Yuliang, Weiwei Shi, Rong Zablocki, Animesh Kumar, Jordan A. Carlson, Sheri J. Hartman, and Mikael Anne Greenwood-Hickman, et al. 2026. "Sedentary Behavior Classification for Wearable Sensors with a CNN-BiLSTM Model (CHAP hip→wrist transfer on iWatch)." arXiv cs.LG, v2 updated. https://arxiv.org/abs/2608.02946.
Chen, Y., Shi, W., Zablocki, R., Kumar, A., Carlson, J. A., Hartman, S. J. and Greenwood-Hickman, M. A. et al. (2026) 'Sedentary Behavior Classification for Wearable Sensors with a CNN-BiLSTM Model (CHAP hip→wrist transfer on iWatch)', arXiv cs.LG, v2 updated. Available at: https://arxiv.org/abs/2608.02946
Chen, Yuliang, et al. "Sedentary Behavior Classification for Wearable Sensors with a CNN-BiLSTM Model (CHAP hip→wrist transfer on iWatch)." arXiv cs.LG, v2 updated, 2026. https://arxiv.org/abs/2608.02946.
Y. Chen et al., "Sedentary Behavior Classification for Wearable Sensors with a CNN-BiLSTM Model (CHAP hip→wrist transfer on iWatch)," arXiv cs.LG, v2 updated, 2026, [Online]. Available: https://arxiv.org/abs/2608.02946.
@misc{chen2026sedentary,
title = {{Sedentary Behavior Classification for Wearable Sensors with a CNN-BiLSTM Model (CHAP hip→wrist transfer on iWatch)}},
author = {Chen, Yuliang and Shi, Weiwei and Zablocki, Rong and Kumar, Animesh and Carlson, Jordan A. and Hartman, Sheri J. and Greenwood-Hickman, Mikael Anne and Hibbing, Paul R. and Jankowska, Marta and Yang, Jay and Zou, Jingjing and Kumar, Arun and Natarajan, Loki},
year = {2026},
howpublished = {arXiv cs.LG, v2 updated},
eprint = {2608.02946},
archivePrefix = {arXiv}
}Added to the ChatPPG research hub