Model

UAMMS (uncertainty-aware meta-learned model switching)

Cite
UnconfirmedCatalog paper date: 2026Added to atlas: Nov 20, 2026Source

Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.

Reusable on-device pattern: a cheap compressed model runs by default and escalates to a full-precision model when MC-dropout uncertainty crosses a threshold. On a reconstructed 4-class PhysioNet/CinC 2017 comparison (random 64/16/20 split, 5 seeds), MC dropout reached accuracy 0.810 ± 0.012 and macro-F1 0.739 ± 0.022 (abstract). Paper: mhamdi-uamms-uncertainty-meta-learned-model-switching-wearable-cardiac-cbm-2026.

Signals
ECG, time series
Pretraining data
n/a (task-trained)
License
none released
Year
2026
Architecture

MAML subject adaptation; compressed model zoo (structured pruning, quantization, distillation); resource-aware switching controller using MC-dropout uncertainty and device telemetry, falling back to a high-fidelity model above an uncertainty threshold (abstract)

At a glance
Type
Task model
Modalities
ECGtime series
Form factor
Not reported
Parameters
Not reported
Architecture
MAML subject adaptation; compressed model zoo (structured pruning, quantization, distillation); resource-aware switching controller using MC-dropout uncertainty and device telemetry, falling back to a high-fidelity model above an uncertainty threshold (abstract)
Venue
Not reported
Year
2026
arXiv
Not reported
Code
Not released
Weights
Not released
Licence
none released
Caveats
Not reported
Added
Nov 20, 2026
Updated
Nov 20, 2026

Abstract

Wearable cardiac monitoring during sport requires predictive models that remain reliable under subject-specific physiology, motion artifacts, non-stationary exercise states, and stringent energy constraints. This study presents Uncertainty-Aware Meta-Learned Model Switching (UAMMS), a proof-of-concept framework for adaptive inference on wearable devices using physiological signals. UAMMS combines model-agnostic meta-learning for rapid subject-specific adaptation, a compressed model zoo generated by structured pruning, quantization, and knowledge distillation, and a resource-aware switching controller informed by Monte Carlo dropout uncertainty estimates and device telemetry. When predictive uncertainty exceeds a predefined threshold, the controller falls back to a high-fidelity model and initiates lightweight online adaptation. The original prototype evaluation reported an F1 score of 0.90 and a 59% reduction in energy relative to the static full-precision baseline; these figures refer to the manuscript's original binary/proxy-task and energy-accounting protocol. In a separate reconstructed four-class PhysioNet/CinC 2017 comparison using a fixed 64/16/20 train/validation/test split and five random-seed repetitions, MC dropout achieved mean accuracy 0.810 ± 0.012 and macro-F1 0.739 ± 0.022. A three-member deep ensemble achieved the highest mean accuracy (0.823 ± 0.003) and macro-F1 (0.756 ± 0.005), while temperature scaling reduced expected calibration error for all methods. These comparator results are reported separately and do not replace or directly validate the original UAMMS prototype results. The available latency records do not establish that the manuscript's 19.8 ± 1.2 ms system-level value includes all ten MC-dropout passes; the 125-452 ms figure is a first-order estimate derived from the original single-pass ARM Cortex-M7 timings. The new inference profile was collected in a separate Kaggle runtime and is not a target-wearable measurement. The datasets and labels do not constitute prospective clinical diagnosis of heart disease in athletes; the findings remain methodological and require external prospective validation before clinical deployment.

Verbatim fromEurope PMC· Abstract via Europe PMC; © the authors/publisher

UAMMS (uncertainty-aware meta-learned model switching): ChatPPG research summary card

Key results

0.810
accuracy
On a reconstructed 4-class PhysioNet/CinC 2017 comparison (random 64/16/20 split, 5 seeds), MC dropout reached accuracy 0.810 ± 0.012 and…

How it works

How UAMMS (uncertainty-aware meta-learned model switching) works: Input signals → Model → Downstream tasksInput signals: ECG (Electrocardiogram); time series. Dataset: PhysioNet/CinC Challenge 2017: AF classification from a short single-lead ECG (AliveCor). Model: UAMMS (uncertainty-aware meta-learned model switching) (Masked reconstruction).Input signalsECG: ElectrocardiogramECGElectrocardiogramtime seriestime seriesDataset: PhysioNet/CinC Challenge 2017: AF classification from a short single-lead ECG (AliveCor)DatasetPhysioNet/CinC Challenge 2017: AF…ModelMASK → RECONSTRUCTUAMMS (uncertainty-aware…Masked reconstruction

Datasets linked in the hub; pretraining vs evaluation roles follow the paper.

Pretraining data
n/a (task-trained)
Architecture
MAML subject adaptation; compressed model zoo (structured pruning, quantization, distillation); resource-aware switching controller using MC-dropout uncertainty and device telemetry, falling back to a high-fidelity model above an uncertainty threshold (abstract)
Inputs
ECG, time series
Approach
on device · model switching · uncertainty · mc dropout · maml · no code

Datasets used· 1

Cite this model

Cite the publication recorded for this model. Check it against the publisher before submitting.

UAMMS (uncertainty-aware meta-learned model switching). (2026). https://doi.org/10.1016/j.compbiomed.2026.112078
@misc{uamms2026uamms,
  title         = {{UAMMS (uncertainty-aware meta-learned model switching)}},
  year          = {2026},
  doi           = {10.1016/j.compbiomed.2026.112078}
}

History

  1. Added to the ChatPPG research hub