2026
Form factor
Clinical
ECGTextWACV 2027Weights: not released
Nguyen, Huynh Dang et al., "IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for Electrocardiogram", arXiv:2610.28083, CC BY 4.0
Venue listedCatalog paper date: 2026Added to atlas: Oct 21, 2026Source

Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.

Point-level abnormality localization AUROC 75.55 % on ECGAD (190 cardiologist-annotated abnormal PTB-XL samples), reported as SOTA vs attribution baselines. Classification is "competitive" but below TolerantECG on all four columns of the authors' Appendix K table (e.g. 80.06 vs 81.53).

Signals
ECG, Text
Pretraining data
MIMIC-IV-ECG: >800k 10-s 12-lead ECGs, ~160k patients
Form factor
Clinical
License
No code or weights released or promised.
Year
2026
Architecture

1-D ViT ECG encoder (12 layers, 12 heads, width 768, patch 50) with spatial-temporal lead/time embedding over the flattened 12-lead signal; frozen MedCPT text encoder; multimodal text decoder for report captioning; CLS attention supervised by clinical-rule heatmap pseudo-labels (KL loss, gamma 0.5) from a UNet3+ wave-delineation pipeline

At a glance
Type
Foundation model
Modalities
ECGText
Form factor
Clinical
Parameters
Not reported
Architecture
1-D ViT ECG encoder (12 layers, 12 heads, width 768, patch 50) with spatial-temporal lead/time embedding over the flattened 12-lead signal; frozen MedCPT text encoder; multimodal text decoder for report captioning; CLS attention supervised by clinical-rule heatmap pseudo-labels (KL loss, gamma 0.5) from a UNet3+ wave-delineation pipeline
Venue
WACV 2027 (accepted, per arXiv comment); arXiv 2610.28083v1 2026-10-20
Year
2026
DOI
Not reported
Code
Not released
Weights
Not released
Licence
No code or weights released or promised.
Caveats
Not reported
Added
Oct 21, 2026
Updated
Oct 26, 2026

Abstract

Electrocardiography (ECG) is a cornerstone of cardiac diagnosis, yet most machine learning methods for ECG analysis lack interpretability, limiting their clinical adoption. We present IECG, a weakly-supervised ECG foundation model that jointly performs diagnostic classification and abnormality localization without requiring manual abnormal region annotations, overcoming a long-standing bottleneck in interpretable ECG learning. Central to IECG is a weakly-supervised attention strategy that explicitly incorporates clinical priors by deriving abnormality heatmap pseudo-labels from established ECG clinical knowledge. These pseudo-labels guide the model's CLS-token attention through a KL-divergence loss, encouraging it to focus on diagnostically relevant waveform regions. During pretraining, IECG is jointly optimized with clinically guided attention supervision, ECG-text contrastive alignment, and report captioning objectives, enabling it to learn rich multimodal representations while producing localized waveform evidence. By explicitly aggregating features from clinically guided attention regions, IECG grounds its diagnostic predictions in interpretable waveform evidence without sacrificing classification performance. Extensive experiments demonstrate that IECG achieves state-of-the-art abnormal region localization while maintaining strong classification performance, advancing trustworthy foundation models for ECG analysis.

Verbatim fromarXiv· arXiv metadata (abstracts are released under CC0)

Key results

75.55 %
AUROC
Point-level abnormality localization AUROC 75.55 % on ECGAD (190 cardiologist-annotated abnormal PTB-XL samples), reported as SOTA vs att…

How it works

How IECG works: Input signals → Foundation model → Downstream tasksInput signals: ECG (Electrocardiogram); Text (Language). Datasets: MIMIC-IV-ECG, PTB-XL, Chapman–Shaoxing–Ningbo 12-lead ECG arrhythmia database (PhysioNet). Foundation model: IECG (Transformer · Convolutional network).Input signalsECG: ElectrocardiogramECGElectrocardiogramText: LanguageTextLanguageDatasets: MIMIC-IV-ECG, PTB-XL, Chapman–Shaoxing–Ningbo 12-lead ECG arrhythmia database (PhysioNet)DatasetsMIMIC-IV-ECG, PTB-XL +1 moreFoundation model×NIECGTransformer · Convolutional network

Datasets linked in the hub; pretraining vs evaluation roles follow the paper.

Pretraining data
MIMIC-IV-ECG: >800k 10-s 12-lead ECGs, ~160k patients
Architecture
1-D ViT ECG encoder (12 layers, 12 heads, width 768, patch 50) with spatial-temporal lead/time embedding over the flattened 12-lead signal; frozen MedCPT text encoder; multimodal text decoder for report captioning; CLS attention supervised by clinical-rule heatmap pseudo-labels (KL loss, gamma 0.5) from a UNet3+ wave-delineation pipeline
Inputs
ECG, Text
Approach
ECG · foundation model · interpretability · attention supervision · ECG text contrastive · captioning

Datasets· 3

Papers· 1

Cite

APA

Nguyen, H. D., Pham, T.-T., Do, A.-T., Dinh, P.-N., Patel, B., Le, N., & Nguyen, V. (2026). IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for Electrocardiogram. WACV 2027. https://arxiv.org/abs/2610.28083

BibTeX

@article{nguyen2026iecg,
  title         = {{IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for Electrocardiogram}},
  author        = {Nguyen, Huynh Dang and Pham, Trong-Thang and Do, Anh-Thuan and Dinh, Phuong-Nhi and Patel, Brijesh and Le, Ngan and Nguyen, Van},
  year          = {2026},
  journal       = {WACV 2027},
  eprint        = {2610.28083},
  archivePrefix = {arXiv}
}

Built from the hub record. Check it against the publisher before submitting.