PaperarXiv:2606.25116

BCoughBench: Benchmarking Respiratory Acoustic Foundation Models Under Body-Coupled Wearable Sensor Conditions

Preprint2026Added Nov 1, 2026

arXiv 2606.25116 (submitted 2026-06-23 per arXiv published timestamp)

First page or project page of “BCoughBench: Benchmarking Respiratory Acoustic Foundation Models Under Body-Coupled Wearable Sensor Conditions” (opens in a new tab)

Sanap, Mayur et al., "BCoughBench: Benchmarking Respiratory Acoustic Foundation Models Under Body-Coupled Wearable Sensor Conditions", arXiv:2606.25116, CC BY 4.0

TL;DR

Sanap, Desikan, Lobaton. arXiv:2606.25116, arXiv published timestamp 2026-06-23T19:43:03Z. Carded 2026-11-08 from the arXiv export-API abstract.

  • Form factor: body-coupled wearable (vs smartphone audio)

Abstract

Respiratory acoustic foundation models (FMs) are benchmarked exclusively on smartphone recordings, yet clinical deployment increasingly targets body-coupled (BC) wearables whose sensors attenuate high-frequency content through tissue and bone, leaving FM reliability uncharacterised. We introduce BCoughBench, evaluating five FMs (OPERA-CT/CE/GT, HeAR, M2D+Resp) on nine classification tasks (AUROC, sensitivity at 95% specificity, Expected Calibration Error) and three age regression tasks (MAE vs. a mean-predictor baseline) across five EBEN-simulated BC sensor conditions on five labeled cough datasets. Mean AUROC declines from 0.785 (smartphone) to 0.689-0.723, degrading most under temple vibration pickup ( = -0.096) and least under the soft in-ear ( = -0.062). No FM meets the clinical sensitivity threshold (Se@Sp95 ≥ 0.20) on most disease tasks under any BC sensor. Sex classification on the CIDRZ cohort collapses (AUROC 0.954 to 0.596-0.628, = -0.341) while COVID detection is nearly unaffected ( = -0.004). Age regression is robust, improving under the forehead accelerometer on CoughVID (MAE 9.61 to 8.97 yr); HeAR leads on regression and demographic tasks, M2D+Resp on disease and characteristic tasks. BCoughBench provides a reproducible framework for FM evaluation under wearable conditions.

Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Respiration

Signals

Keywords

BenchmarkCoughRespiratoryFoundation ModelWearable

How it works

How Method works: Setup → Method → TargetSetup: Signals (audio); Form factor (body-coupled wearable (vs smartphone audio)). Method: Method. Target: Respiration.SetupSignals: audioSignalsaudioForm factor: body-coupled wearable (vs smartphone audio)Form factorbody-coupled wearable (vs smartphone…MethodMethodTargetRespirationRespiration

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

BCoughBench: Benchmarking Respiratory Acoustic Foundation Models Under Body-Coupled Wearable Sensor Conditions. (2026). arXiv 2606.25116. https://arxiv.org/abs/2606.25116
@misc{sanapbcoughbench2026bcoughbench,
  title         = {{BCoughBench: Benchmarking Respiratory Acoustic Foundation Models Under Body-Coupled Wearable Sensor Conditions}},
  year          = {2026},
  howpublished  = {arXiv 2606.25116},
  eprint        = {2606.25116},
  archivePrefix = {arXiv}
}

Source metadata: 2026

Record updated Nov 8, 2026