Paperdoi:10.1038/s41598-022-07314-0

Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict study

Venue listed2022Added Nov 22, 2026

  • AM
  • FH
  • SD
  • JN

Authors: AE Mason, FM Hecht, SK Davis, JL Natale

Scientific Reports, 2022

TL;DR

First TemPredict study: Oura ring finger skin temperature, heart rate, HRV and respiratory rate from 63,153 participants, with a COVID-19 detection model trained on 73 PCR-confirmed cases. It detected COVID-19 on average 2.75 days before testing with sensitivity 82%, specificity 63% and AUC 0.819, adding continuous temperature raised AUC by 4.9%, and accuracy varied with age and sex.

Abstract

Early detection of diseases such as COVID-19 could be a critical tool in reducing disease transmission by helping individuals recognize when they should self-isolate, seek testing, and obtain early medical intervention. Consumer wearable devices that continuously measure physiological metrics hold promise as tools for early illness detection. We gathered daily questionnaire data and physiological data using a consumer wearable (Oura Ring) from 63,153 participants, of whom 704 self-reported possible COVID-19 disease. We selected 73 of these 704 participants with reliable confirmation of COVID-19 by PCR testing and high-quality physiological data for algorithm training to identify onset of COVID-19 using machine learning classification. The algorithm identified COVID-19 an average of 2.75 days before participants sought diagnostic testing with a sensitivity of 82% and specificity of 63%. The receiving operating characteristic (ROC) area under the curve (AUC) was 0.819 (95% CI [0.809, 0.830]). Including continuous temperature yielded an AUC 4.9% higher than without this feature. For further validation, we obtained SARS CoV-2 antibody in a subset of participants and identified 10 additional participants who self-reported COVID-19 disease with antibody confirmation. The algorithm had an overall ROC AUC of 0.819 (95% CI [0.809, 0.830]), with a sensitivity of 90% and specificity of 80% in these additional participants. Finally, we observed substantial variation in accuracy based on age and biological sex. Findings highlight the importance of including temperature assessment, using continuous physiological features for alignment, and including diverse populations in algorithm development to optimize accuracy in COVID-19 detection from wearables.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Keywords

Core Body Temperature

How it works

How Method works: Setup → Method → TargetSetup: Signals (finger skin temperature, HR, HRV, respiratory rate (Oura)). Method: Method.SetupSignals: finger skin temperature, HR, HRV, respiratory rate (Oura)Signalsfinger skin temperature, HR, HRV…MethodMethod

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Mason, A., Hecht, F., Davis, S., Natale, J., et al. (2022). Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict study. Scientific Reports, 2022. https://doi.org/10.1038/s41598-022-07314-0
Mason, AE, FM Hecht, SK Davis, and JL Natale, et al. 2022. "Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict study." Scientific Reports, 2022. https://doi.org/10.1038/s41598-022-07314-0.
Mason, A., Hecht, F., Davis, S. and Natale, J. et al. (2022) 'Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict study', Scientific Reports, 2022. doi: 10.1038/s41598-022-07314-0.
Mason, AE, et al. "Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict study." Scientific Reports, 2022, 2022. https://doi.org/10.1038/s41598-022-07314-0.
A. Mason et al., "Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict study," Scientific Reports, 2022, 2022, doi: 10.1038/s41598-022-07314-0.
@article{mason2022detection,
  title         = {{Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict study}},
  author        = {Mason, AE and Hecht, FM and Davis, SK and Natale, JL and others},
  year          = {2022},
  journal       = {Scientific Reports, 2022},
  doi           = {10.1038/s41598-022-07314-0}
}

Added to the ChatPPG research hub