Paperdoi:10.1016/j.cmpb.2026.109547

WatchForce: wrist-worn PPG and IMU sensing for hand force estimation (stub)

Venue listed2026Added Nov 1, 2026

  • H
  • Z
  • C
  • G
  • C
  • JR

Authors: Hu, Zhang, Choi, Gao, Chauhan, Jin (full names not in fetched record)

Computer Methods and Programs in Biomedicine (2026-07-01)

TL;DR

Title, venue, DOI and author surnames from OpenAlex; no abstract available in OpenAlex/S2. The title states wrist PPG + IMU are used to estimate hand force.

  • Form factor: wrist

Abstract

Background and objectiveRecent advancements in extended reality have reshaped human-computer interaction; yet, force estimation remains a critical missing element for achieving realistic interactions. Unlike traditional electromyography-based systems, which are highly accurate but hindered by usability challenges, this paper introduces WatchForce, a novel wrist-worn system that estimates hand force using photoplethysmography and an inertial measurement unit. The objective is to investigate whether smartwatch-compatible photoplethysmography and inertial measurement unit signals can support three-level force classification and MVC-normalized force regression under controlled experimental conditions.MethodsWatchForce employs a Vision Transformer-based model with a multimodal alignment strategy based on bidirectional InfoNCE. This approach separately encodes photoplethysmography and inertial measurement unit signals and aligns their representations for multimodal force estimation.ResultsWatchForce achieves 86.31% force classification accuracy under the session-level universal-model setting and 88.32% in user-dependent models. Under the same session-level universal-model setting, the regression task yields an nRMSE of 0.1386 on MVC-normalized force values and an R2 of 78.24%. In a leave-one-subject-out (LOSO) cross-subject evaluation, the PPG+IMU model achieves 78.50% classification accuracy and 0.1509 nRMSE/68.04% R2 for regression, providing initial evidence of generalization to held-out participants within the collected cohort. Additional posture, motion, and lighting evaluations further support robustness under the tested conditions, while broader population-level validation remains an important direction for future work.ConclusionsWatchForce provides proof-of-concept evidence that smartwatch-compatible PPG and IMU signals can support wrist-based hand-force estimation. Future studies with larger and more diverse cohorts, long-term daily-use evaluation, and commercial smartwatch hardware-level validation will be important for extending these findings toward real-world use.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Hand ForceGripHCI

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG, IMU); Form factor (wrist). Method: Method.SetupSignals: PPG, IMUSignalsPPG, IMUForm factor: wristForm factorwristMethodMethod

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

WatchForce: wrist-worn PPG and IMU sensing for hand force estimation (stub). (2026). Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2026.109547
@article{huwatchforcewris2026watchforce,
  title         = {{WatchForce: wrist-worn PPG and IMU sensing for hand force estimation (stub)}},
  year          = {2026},
  journal       = {Computer Methods and Programs in Biomedicine},
  doi           = {10.1016/j.cmpb.2026.109547}
}

Added to the ChatPPG research hub