Paperdoi:10.1364/ao.57.000b45
Large-scale clinical validation of noncontact and continuous extraction of blood pressure via multipoint defocused photonic imaging
Applied Optics 57(7):B45, 2017
TL;DR
A remote optical system tracked laser speckle patterns reflected from the skin at several points to measure pulse transit time without contact, then converted it to systolic and diastolic blood pressure with a model compared against a reference monitor.
- Form factor: camera
Abstract
Blood pressure (BP) is usually measured either invasively, by an intra-arterial catheter, or noninvasively, by a cuff-based sphygmomanometer. While the invasive method is continuous and more accurate, it has the risk of infection and generally is not comfortable for the patient. On the other hand, the cuff-based measurement is safer but less reliable and infrequent. Therefore, a reliable continuous noninvasive BP measurement is highly desirable. In this work, we propose a remote optical system, based on temporal analysis of secondary reflected speckle patterns, for computing a subject's pulse transit time (PTT). Afterward, a model is proposed and clinically validated for converting the PTT value into systolic and diastolic blood pressure. A full statistical analysis is performed over a comparison to a reference device (SOMNOtouch).
Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
- Wavelengths
- laser (λ not in abstract)
Cite this paper
Golberg, M., Ruiz-Rivas, J., Polani, S., Beiderman, Y., & Zalevsky, Z. (2017). Large-scale clinical validation of noncontact and continuous extraction of blood pressure via multipoint defocused photonic imaging. Applied Optics , 2017, 57(7), B45. https://doi.org/10.1364/ao.57.000b45
Golberg, Mark, J. Ruiz-Rivas, Sagi Polani, Yevgeny Beiderman, and Zeev Zalevsky. 2017. "Large-scale clinical validation of noncontact and continuous extraction of blood pressure via multipoint defocused photonic imaging." Applied Optics , 2017 57 (7): B45. https://doi.org/10.1364/ao.57.000b45.
Golberg, M., Ruiz-Rivas, J., Polani, S., Beiderman, Y. and Zalevsky, Z. (2017) 'Large-scale clinical validation of noncontact and continuous extraction of blood pressure via multipoint defocused photonic imaging', Applied Optics , 2017, 57(7), p. B45. doi: 10.1364/ao.57.000b45.
Golberg, Mark, et al. "Large-scale clinical validation of noncontact and continuous extraction of blood pressure via multipoint defocused photonic imaging." Applied Optics , 2017, vol. 57, no. 7, 2017, p. B45. https://doi.org/10.1364/ao.57.000b45.
M. Golberg, J. Ruiz-Rivas, S. Polani, Y. Beiderman, and Z. Zalevsky, "Large-scale clinical validation of noncontact and continuous extraction of blood pressure via multipoint defocused photonic imaging," Applied Optics , 2017, vol. 57, no. 7, p. B45, 2017, doi: 10.1364/ao.57.000b45.
@article{golberg2017largescale,
title = {{Large-scale clinical validation of noncontact and continuous extraction of blood pressure via multipoint defocused photonic imaging}},
author = {Golberg, Mark and Ruiz-Rivas, J. and Polani, Sagi and Beiderman, Yevgeny and Zalevsky, Zeev},
year = {2017},
journal = {Applied Optics , 2017},
volume = {57},
number = {7},
pages = {B45},
doi = {10.1364/ao.57.000b45}
}Added to the ChatPPG research hub