Paper

ECG-RSI: Recursive Self-Improvement through Targeted Electrocardiogram Waveform Evolution

Xiaoliang Wang, Zhuo Chen, Chuanyang Zheng, Jiangwei Lao, Quanbin Wang, Honglin Lin +5 more
arXiv 2610.177182026ECGOpen code
PreprintFirst posted: Oct 13, 2026Added to atlas: Oct 14, 2026Source
Citations—Not available
GitHub stars—Not available
HF downloads—Not available

Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.

ECG models need supervision that targets evolving weaknesses and stays faithful to waveform evidence. Across seven benchmarks and three rounds, Qwen3.5-35B-A3B mean question-answering accuracy rises from 34.57% → 56.04% and mean classification F1 from 24.27 → 34.03.

  • Venue: arXiv 2610.17718 (2026-10-13, cs.AI / cs.LG / eess.SP / q-bio.QM)
  • Signals: ECG
  • Form factor: clinical
At a glance
Venue
arXiv 2610.17718 (2026-10-13, cs.AI / cs.LG / eess.SP / q-bio.QM)
Published
2026
DOI
Not reported
PMID
Not reported
Licence
Not reported
Signals
ECG
Form factor
Clinical
Subjects
Not reported
Code
Open
Added
Oct 14, 2026

Abstract

Electrocardiogram (ECG) models need supervision that targets evolving weaknesses and remains faithful to waveform evidence. We introduce ECG-RSI, a recursive self-improvement framework combining verified waveform synthesis with feedback-guided intervention search. Signal remeasurement verifies waveform edits; construction errors guide generator repair, while learner errors motivate interventions compared on a separate selection set. Across seven benchmarks, three rounds raise Qwen3.5-35B-A3B's mean question-answering accuracy from 34.57% to 56.04% and mean classification F1 from 24.27 to 34.03. Across the retained trajectory, the preferred supervision shifts from direct reinforcement to confusion-focused contrasts. Continued feedback correction yields diminishing external gains. These results motivate separating error diagnosis from intervention selection and checking whether gains on the feedback set transfer to independent benchmarks.

Verbatim fromarXiv· arXiv metadata (abstracts are released under CC0)

ECG-RSI: Recursive Self-Improvement through Targeted Electrocardiogram Waveform Evolution: ChatPPG research summary card

Key results

34.57%
accuracy
Across seven benchmarks and three rounds, Qwen3.5-35B-A3B mean question-answering accuracy rises from 34.57% → 56.04% and mean classifica…

How it works

How Method works: Setup → Method → TargetSetup: Signals (ECG); Form factor (clinical). Method: Method (Language-aligned).SetupSignals: ECGSignalsECGForm factor: clinicalForm factorclinicalMethodMethodLanguage-aligned

Cite

@article{ecgrsirecursiveselfimpro2026,
  title = {{ECG-RSI: Recursive Self-Improvement through Targeted Electrocardiogram Waveform Evolution}},
  author = {Xiaoliang Wang and Zhuo Chen and Chuanyang Zheng and Jiangwei Lao and Quanbin Wang and Honglin Lin and Jiajia Liu and Zhihong Lu and Hao Jin and Jian Wang and Lijun Wu},
  year = {2026},
  journal = {arXiv 2610.17718 (2026-10-13, cs.AI / cs.LG / eess.SP / q-bio.QM)},
  eprint = {2610.17718},
  url = {https://arxiv.org/abs/2610.17718}
}

History

  1. Added to the ChatPPG research hub