CLMT is a small (0.09B parameter) model that translates between physiological signals, such as PPG to ECG, and between sampling rates using a two-stage discrete latent approach. In PPG-to-ECG synthesis it raised R-peak detection F1 from 0.37 to 0.83, and upsampling from 25 Hz to 100 Hz reached a Pearson correlation of 0.9956.

  • Parameters: 0.09B
  • Signals: PPG, ECG
  • Result: PPG-to-ECG R-peak F1 0.37 to 0.83
  • Result: 25 Hz to 100 Hz super-resolution, r = 0.9956
At a glance
Venue
arXiv preprint
Published
2026
DOI
Not reported
PMID
Not reported
Licence
Not reported
Signals
PPGECG
Form factor
Not reported
Subjects
Not reported
Code
Not reported
Added
Oct 13, 2026

Abstract

The analysis of physiological time series, such as electrocardiograms (ECG) and photoplethysmograms (PPG), is persistently hindered by modality and frequency gaps stemming from heterogeneous recording devices. Existing foundation models typically rely on continuous latent spaces, which frequently suffer from severe modality entanglement, lack high-fidelity cross-frequency generative capacity, and impose high computational costs that prohibit edge-device deployment. In this paper, we propose Compact Latent Manifold Translation (CLMT), a highly parameter-efficient (0.09B) unified framework that bridges these gaps through a novel two-stage discrete translation paradigm. First, we introduce a Universal Tokenizer utilizing Hierarchical Residual Vector Quantization (RVQ) to decouple heterogeneous signals into isolated, well-structured discrete latent manifolds, effectively preventing inter-modality interference. Second, a Context-Prompted Latent Translator maps these discrete tokens across modalities by integrating static physiological priors, reframing complex signal synthesis as a pure latent sequence translation task. Extensive evaluations demonstrate that our 0.09B model significantly outperforms massive baselines. In cross-modal PPG-to-ECG synthesis, it resolves temporal phase drift and dramatically improves the clinical R-peak detection F1-score from 0.37 (baseline) to 0.83. Furthermore, in extreme cross-frequency super-resolution (25Hz to 100Hz), it successfully recovers high-frequency diagnostic landmarks, achieving an unprecedented Pearson correlation of 0.9956. By learning a universal discrete language for biological signals with a fraction of the computational footprint, our approach sets a new trajectory for edge-deployable, multi-modal medical foundation models.

Verbatim fromarXiv· arXiv metadata (abstracts are released under CC0)

Compact Latent Manifold Translation: A Parameter-Efficient Foundation Model for Cross-Modal and Cross-Frequency Physiological Signal Synthesis: ChatPPG research summary card

Key results

0.37
F1
In PPG-to-ECG synthesis it raised R-peak detection F1 from 0.37 to 0.83, and upsampling from 25 Hz to 100 Hz reached a Pearson correlatio…

How it works

How Method works: Setup → Method → ResultSetup: Signals (PPG, ECG). Method: Method. Result: Result (PPG-to-ECG R-peak F1 0.37 to 0.83); Result (25 Hz to 100 Hz super-resolution, r = 0.9956).SetupSignals: PPG, ECGSignalsPPG, ECGMethodMethodResultResult: PPG-to-ECG R-peak F1 0.37 to 0.83ResultPPG-to-ECG R-peak F1 0.37 to 0.83Result: 25 Hz to 100 Hz super-resolution, r = 0.9956Result25 Hz to 100 Hz super-resolution, r =…

Cite

@article{clmtcompactlatentmanifol2026,
  title = {{Compact Latent Manifold Translation: A Parameter-Efficient Foundation Model for Cross-Modal and Cross-Frequency Physiological Signal Synthesis}},
  author = {Bo Cui and Xiaowen Song and Yaowen Zhang and Shunzhe Zhang and B. J. F. van Beijnum and Monique Tabak and Ying Wang},
  year = {2026},
  journal = {arXiv preprint},
  eprint = {2605.13248},
  url = {https://arxiv.org/abs/2605.13248}
}

History

  1. Added to the ChatPPG research hub