Paperdoi:10.1007/s10877-010-9248-y

Measuring venous oxygenation using the photoplethysmograph waveform

Venue listed2010Added Nov 5, 2026

  • ZW
  • PK
  • DS
  • KS

Authors: Zachary D. Walton, Panayiotis A. Kyriacou, David G. Silverman, Kirk H. Shelley

Journal of Clinical Monitoring and Computing

TL;DR

Fundamental to the successful isolation of the venous saturation is the identification of PPG characteristics that are unique to the peripheral venous system. Two such characteristics have been identified. First, the peripheral venous waveform tends to reflect atrial contraction.

  • Published in Journal of Clinical Monitoring and Computing (2010).

Abstract

ObjectiveWe investigate the hypothesis that the photoplethysmograph (PPG) waveform can be analyzed to infer regional venous oxygen saturation.MethodsFundamental to the successful isolation of the venous saturation is the identification of PPG characteristics that are unique to the peripheral venous system. Two such characteristics have been identified. First, the peripheral venous waveform tends to reflect atrial contraction. Second, ventilation tends to move venous blood preferentially due to the low pressure and high compliance of the venous system. Red (660 nm) and IR (940 nm) PPG waveforms were collected from 10 cardiac surgery patients using an esophageal PPG probe. These waveforms were analyzed using algorithms written in Mathematica. Four time-domain saturation algorithms (ArtSat, VenSat, ArtInstSat, VenInstSat) and four frequency-domain saturation algorithms (RespDC, RespAC, Cardiac, and Harmonic) were applied to the data set.ResultsThree of the algorithms for calculating venous saturation (VenSat, VenInstSat, and RespDC) demonstrate significant difference from ArtSat (the conventional time-domain algorithm for measuring arterial saturation) using the Wilcoxon signed-rank test with Bonferroni correction (p ConclusionsThis work introduces new algorithms for PPG analysis. Three algorithms (VenSat, VenInstSat, and RespDC) succeed in detecting lower saturation blood. The next step is to confirm the accuracy of the measurement by comparing them to a gold standard (i.e., venous blood gas).

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

SpO₂

Signals

Keywords

Kyriacou BibliographyPulse Oximetry Oxygenation

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method. Target: SpO₂.SetupSignals: PPGSignalsPPGMethodMethodTargetSpO₂O₂SpO₂

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Walton, Z. D., Kyriacou, P. A., Silverman, D. G., & Shelley, K. H. (2010). Measuring venous oxygenation using the photoplethysmograph waveform. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-010-9248-y
Walton, Zachary D., Panayiotis A. Kyriacou, David G. Silverman, and Kirk H. Shelley. 2010. "Measuring venous oxygenation using the photoplethysmograph waveform." Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-010-9248-y.
Walton, Z. D., Kyriacou, P. A., Silverman, D. G. and Shelley, K. H. (2010) 'Measuring venous oxygenation using the photoplethysmograph waveform', Journal of Clinical Monitoring and Computing. doi: 10.1007/s10877-010-9248-y.
Walton, Zachary D., et al. "Measuring venous oxygenation using the photoplethysmograph waveform." Journal of Clinical Monitoring and Computing, 2010. https://doi.org/10.1007/s10877-010-9248-y.
Z. D. Walton, P. A. Kyriacou, D. G. Silverman, and K. H. Shelley, "Measuring venous oxygenation using the photoplethysmograph waveform," Journal of Clinical Monitoring and Computing, 2010, doi: 10.1007/s10877-010-9248-y.
@article{walton2010measuring,
  title         = {{Measuring venous oxygenation using the photoplethysmograph waveform}},
  author        = {Walton, Zachary D. and Kyriacou, Panayiotis A. and Silverman, David G. and Shelley, Kirk H.},
  year          = {2010},
  journal       = {Journal of Clinical Monitoring and Computing},
  doi           = {10.1007/s10877-010-9248-y}
}

Added to the ChatPPG research hub