Paperdoi:10.3390/s25020559

Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry

Venue listed2025Added Nov 5, 2026

Authors: Raghda Al-Halawani, Meha Qassem, Panicos A. Kyriacou

Sensors

First page or project page of “Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry” (opens in a new tab)

Raghda Al-Halawani et al., "Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry", doi:10.3390/s25020559, CC BY 4.0

TL;DR

Over the past ten years, there has been an increasing demand for reliable consumer wearables as users are inclined to monitor their health and fitness metrics in real-time, especially since the COVID-19 pandemic. Reflectance pulse oximeters in fitness trackers and smartwatches provide convenient, non-invasive SpO2 measurements but face challenges in achieving medical-grade accuracy, particularly due to difficulties in capturing physiological signals, which may be affected by skin pigmentation. Hence, this study sets out to investigate the influence of skin pigmentation, particularly in individuals with darker skin, on the accuracy and reliability of SpO2 measurement in consumer wearables that utilise reflectance pulse oximeters.

Abstract

Over the past ten years, there has been an increasing demand for reliable consumer wearables as users are inclined to monitor their health and fitness metrics in real-time, especially since the COVID-19 pandemic. Reflectance pulse oximeters in fitness trackers and smartwatches provide convenient, non-invasive SpO2 measurements but face challenges in achieving medical-grade accuracy, particularly due to difficulties in capturing physiological signals, which may be affected by skin pigmentation. Hence, this study sets out to investigate the influence of skin pigmentation, particularly in individuals with darker skin, on the accuracy and reliability of SpO2 measurement in consumer wearables that utilise reflectance pulse oximeters. A Monte Carlo model is developed to assess the effect on simulated reflectance pulse oximetry measurements across light, moderate, and dark skin types for oxygen saturation levels between 70 and 100%. The results indicate that a one-algorithm-fits-all calibration approach may be insufficient, and root mean square errors (RMSEs) of at least 0.3956%, 0.9132%, and 8.4111% for light, moderate, and dark skin are observed when compared to transmittance calibration algorithms. Further research is required to validate these findings and improve the performance of reflectance pulse oximeters in real-world applications, particularly in the context of consumer wearables.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

SpO₂

Signals

Keywords

Kyriacou BibliographyPulse Oximetry Oxygenation

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method. Target: SpO₂.SetupSignals: PPGSignalsPPGMethodMethodTargetSpO₂O₂SpO₂

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Al-Halawani, R., Qassem, M., & Kyriacou, P. A. (2025). Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry. Sensors. https://doi.org/10.3390/s25020559
Al-Halawani, Raghda, Meha Qassem, and Panicos A. Kyriacou. 2025. "Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry." Sensors. https://doi.org/10.3390/s25020559.
Al-Halawani, R., Qassem, M. and Kyriacou, P. A. (2025) 'Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry', Sensors. doi: 10.3390/s25020559.
Al-Halawani, Raghda, et al. "Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry." Sensors, 2025. https://doi.org/10.3390/s25020559.
R. Al-Halawani, M. Qassem, and P. A. Kyriacou, "Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry," Sensors, 2025, doi: 10.3390/s25020559.
@article{alhalawani2025monte,
  title         = {{Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry}},
  author        = {Al-Halawani, Raghda and Qassem, Meha and Kyriacou, Panicos A.},
  year          = {2025},
  journal       = {Sensors},
  doi           = {10.3390/s25020559}
}

Added to the ChatPPG research hub