Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers

Venue listed2012Added Nov 5, 2026

  • MS
  • PK

Authors: M Shafique, P A Kyriacou

Physiological Measurement

TL;DR

Pulse oximetry utilizes the technique of photoplethysmography to estimate arterial oxygen saturation (SpO(2)) values. During hypothermia, the amplitude of the photoplethysmograph (PPG) is compromised which can lead to inaccurate estimation of SpO(2). A new mutlimode PPG/pulse oximeter sensor was developed to investigate the behaviour of PPGs during conditions of induced hypothermia (hand immersed in an ice bath).

  • Published in Physiological Measurement (2012).

Abstract

Pulse oximetry utilizes the technique of photoplethysmography to estimate arterial oxygen saturation (SpO(2)) values. During hypothermia, the amplitude of the photoplethysmograph (PPG) is compromised which can lead to inaccurate estimation of SpO(2). A new mutlimode PPG/pulse oximeter sensor was developed to investigate the behaviour of PPGs during conditions of induced hypothermia (hand immersed in an ice bath). PPG measurements from 20 volunteers were conducted and SpO(2) values were estimated at all stages of the experiment. Good quality PPG signals were observed from the majority of the volunteers at almost all hand temperatures. At low temperature ranges, from 13 to 21 °C, the failure rate to estimate SpO(2) values from the multimode transreflectance PPG sensor was 2.4% as compared to the commercial pulse oximeter with a failure rate of 70%.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

SpO₂

Signals

Keywords

Kyriacou BibliographyPulse Oximetry Oxygenation

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method. Target: SpO₂.SetupSignals: PPGSignalsPPGMethodMethodTargetSpO₂O₂SpO₂

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Shafique, M., & Kyriacou, P. A. (2012). Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers. Physiological Measurement. https://doi.org/10.1088/0967-3334/33/12/2065
Shafique, M and P A Kyriacou. 2012. "Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers." Physiological Measurement. https://doi.org/10.1088/0967-3334/33/12/2065.
Shafique, M. and Kyriacou, P. A. (2012) 'Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers', Physiological Measurement. doi: 10.1088/0967-3334/33/12/2065.
Shafique, M, and P A Kyriacou "Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers." Physiological Measurement, 2012. https://doi.org/10.1088/0967-3334/33/12/2065.
M. Shafique and P. A. Kyriacou, "Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers," Physiological Measurement, 2012, doi: 10.1088/0967-3334/33/12/2065.
@article{shafique2012photoplethysmographic,
  title         = {{Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers}},
  author        = {Shafique, M. and Kyriacou, P. A.},
  year          = {2012},
  journal       = {Physiological Measurement},
  doi           = {10.1088/0967-3334/33/12/2065}
}

Added to the ChatPPG research hub