Paperdoi:10.1088/0967-3334/33/12/2065
Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers
Physiological Measurement
TL;DR
Pulse oximetry utilizes the technique of photoplethysmography to estimate arterial oxygen saturation (SpO(2)) values. During hypothermia, the amplitude of the photoplethysmograph (PPG) is compromised which can lead to inaccurate estimation of SpO(2). A new mutlimode PPG/pulse oximeter sensor was developed to investigate the behaviour of PPGs during conditions of induced hypothermia (hand immersed in an ice bath).
- Published in Physiological Measurement (2012).
Abstract
Pulse oximetry utilizes the technique of photoplethysmography to estimate arterial oxygen saturation (SpO(2)) values. During hypothermia, the amplitude of the photoplethysmograph (PPG) is compromised which can lead to inaccurate estimation of SpO(2). A new mutlimode PPG/pulse oximeter sensor was developed to investigate the behaviour of PPGs during conditions of induced hypothermia (hand immersed in an ice bath). PPG measurements from 20 volunteers were conducted and SpO(2) values were estimated at all stages of the experiment. Good quality PPG signals were observed from the majority of the volunteers at almost all hand temperatures. At low temperature ranges, from 13 to 21 °C, the failure rate to estimate SpO(2) values from the multimode transreflectance PPG sensor was 2.4% as compared to the commercial pulse oximeter with a failure rate of 70%.
Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
Shafique, M., & Kyriacou, P. A. (2012). Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers. Physiological Measurement. https://doi.org/10.1088/0967-3334/33/12/2065
Shafique, M and P A Kyriacou. 2012. "Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers." Physiological Measurement. https://doi.org/10.1088/0967-3334/33/12/2065.
Shafique, M. and Kyriacou, P. A. (2012) 'Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers', Physiological Measurement. doi: 10.1088/0967-3334/33/12/2065.
Shafique, M, and P A Kyriacou "Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers." Physiological Measurement, 2012. https://doi.org/10.1088/0967-3334/33/12/2065.
M. Shafique and P. A. Kyriacou, "Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers," Physiological Measurement, 2012, doi: 10.1088/0967-3334/33/12/2065.
@article{shafique2012photoplethysmographic,
title = {{Photoplethysmographic signals and blood oxygen saturation values during artificial hypothermia in healthy volunteers}},
author = {Shafique, M. and Kyriacou, P. A.},
year = {2012},
journal = {Physiological Measurement},
doi = {10.1088/0967-3334/33/12/2065}
}Added to the ChatPPG research hub