Paperdoi:10.1007/s11517-012-0910-z

Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO2 sensor

Venue listed2012Added Nov 5, 2026

  • MS
  • PK
  • SP

Authors: M. Shafique, P. A. Kyriacou, S. K. Pal

Medical & Biological Engineering & Computing

TL;DR

Photoplethysmography (PPG) is a technique widely used to monitor volumetric blood changes induced by cardiac pulsations. Pulse oximetry uses the technique of PPG to estimate arterial oxygen saturation values (SpO₂). In poorly perfused tissues, SpO₂ readings may be compromised due to the poor quality of the PPG signals.

  • Published in Medical & Biological Engineering & Computing (2012).

Abstract

Photoplethysmography (PPG) is a technique widely used to monitor volumetric blood changes induced by cardiac pulsations. Pulse oximetry uses the technique of PPG to estimate arterial oxygen saturation values (SpO₂). In poorly perfused tissues, SpO₂ readings may be compromised due to the poor quality of the PPG signals. A multimode finger PPG probe that operates simultaneously in reflectance, transmittance and a combined mode called "transreflectance" was developed, in an effort to improve the quality of the PPG signals in states of hypoperfusion. Experiments on 20 volunteers were conducted to evaluate the performance of the multimode PPG sensor and compare the results with a commercial transmittance pulse oximeter. A brachial blood pressure cuff was used to induce artificial hypoperfusion. Results showed that the amplitude of the transreflectance AC PPG signals were significantly different (p < 0.05) than the AC PPG signals obtained from the other two conventional PPG sensors (reflectance and transmittance). At induced brachial pressures between 90 and 135 mmHg, the reflectance finger pulse oximeter failed 25 times (failure rate 42.2 %) to estimate SpO₂ values, whereas the transmittance pulse oximeter failed 8 times (failure rate 15.5 %). The transreflectance pulse oximeter failed only 3 times (failure rate 6.8 %) and the commercial pulse oximeter failed 17 times (failure rate 29.4 %).

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

SpO₂

Signals

Keywords

Kyriacou BibliographyPulse Oximetry Oxygenation

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method. Target: SpO₂.SetupSignals: PPGSignalsPPGMethodMethodTargetSpO₂O₂SpO₂

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Shafique, M., Kyriacou, P. A., & Pal, S. K. (2012). Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO2 sensor. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-012-0910-z
Shafique, M., P. A. Kyriacou, and S. K. Pal. 2012. "Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO2 sensor." Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-012-0910-z.
Shafique, M., Kyriacou, P. A. and Pal, S. K. (2012) 'Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO2 sensor', Medical & Biological Engineering & Computing. doi: 10.1007/s11517-012-0910-z.
Shafique, M., et al. "Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO2 sensor." Medical & Biological Engineering & Computing, 2012. https://doi.org/10.1007/s11517-012-0910-z.
M. Shafique, P. A. Kyriacou, and S. K. Pal, "Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO2 sensor," Medical & Biological Engineering & Computing, 2012, doi: 10.1007/s11517-012-0910-z.
@article{shafique2012investigation,
  title         = {{Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO2 sensor}},
  author        = {Shafique, M. and Kyriacou, P. A. and Pal, S. K.},
  year          = {2012},
  journal       = {Medical \& Biological Engineering \& Computing},
  doi           = {10.1007/s11517-012-0910-z}
}

Added to the ChatPPG research hub