Paperdoi:10.1088/1742-6596/307/1/012016
Photoplethysmographic sensors for perfusion measurements in spinal cord tissue
Journal of Physics: Conference Series
TL;DR
Sensors for recording photoplethysmographic signals from the nervous tissue of the spinal cord are described. The purpose of these sensors is to establish whether perfusion is compromised in various states of injury which occur in certain animal models of spinal cord injury, for example compression injury. Various measures of perfusion are applicable such as the amplitude of the photoplethysmograph signal and the oxygen saturation, measured using a dual wavelength configuration.
Abstract
Sensors for recording photoplethysmographic signals from the nervous tissue of the spinal cord are described. The purpose of these sensors is to establish whether perfusion is compromised in various states of injury which occur in certain animal models of spinal cord injury, for example compression injury. Various measures of perfusion are applicable such as the amplitude of the photoplethysmograph signal and the oxygen saturation, measured using a dual wavelength configuration. Signals are usually compared to baseline measurements made in uninjured subjects. This paper describes two types of probe, one based on optical fibres, and one in which optotes are placed in direct contact with the tissue surface. Results from a study based on a compression model utilising a fibreoptic sensor are presented.
Verbatim from Semantic Scholar (opens in a new tab) · Abstract via Semantic Scholar; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Signals
Keywords
How it works
Cite this paper
Phillips, J. P., & Kyriacou, P. A. (2011). Photoplethysmographic sensors for perfusion measurements in spinal cord tissue. Journal of Physics: Conference Series. https://doi.org/10.1088/1742-6596/307/1/012016
Phillips, J P and P A Kyriacou. 2011. "Photoplethysmographic sensors for perfusion measurements in spinal cord tissue." Journal of Physics: Conference Series. https://doi.org/10.1088/1742-6596/307/1/012016.
Phillips, J. P. and Kyriacou, P. A. (2011) 'Photoplethysmographic sensors for perfusion measurements in spinal cord tissue', Journal of Physics: Conference Series. doi: 10.1088/1742-6596/307/1/012016.
Phillips, J P, and P A Kyriacou "Photoplethysmographic sensors for perfusion measurements in spinal cord tissue." Journal of Physics: Conference Series, 2011. https://doi.org/10.1088/1742-6596/307/1/012016.
J. P. Phillips and P. A. Kyriacou, "Photoplethysmographic sensors for perfusion measurements in spinal cord tissue," Journal of Physics: Conference Series, 2011, doi: 10.1088/1742-6596/307/1/012016.
@inproceedings{phillips2011photoplethysmographic,
title = {{Photoplethysmographic sensors for perfusion measurements in spinal cord tissue}},
author = {Phillips, J. P. and Kyriacou, P. A.},
year = {2011},
booktitle = {Journal of Physics: Conference Series},
doi = {10.1088/1742-6596/307/1/012016}
}Added to the ChatPPG research hub