Paperdoi:10.1109/embc.2013.6610088
Pulse oximetry of body cavities and organs
2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
TL;DR
The focus of this paper will be in the development and in vivo applications of new custom made photoplethysmographic (PPG) and pulse oximetry optical and fiber optic sensors and instrumentation in an effort to investigate their suitability in the estimation of blood oxygen saturation and their contribution in the assessment of organ/tissue perfusion and viability. The paper describes the development of optical and fiber optic PPG and blood oxygen saturation (SpO2) sensors and covers examples of application areas including real-time PPG monitoring from body cavities (esophagus) and solid or hollow organs (bowel, liver, stomach, brain, etc). The clinical studies presented successfully demonstrated the feasibility in acquiring PPGs and estimating blood oxygen saturation values from a variety of organs and tissues.
- Published in 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (2013).
Abstract
The focus of this paper will be in the development and in vivo applications of new custom made photoplethysmographic (PPG) and pulse oximetry optical and fiber optic sensors and instrumentation in an effort to investigate their suitability in the estimation of blood oxygen saturation and their contribution in the assessment of organ/tissue perfusion and viability. The paper describes the development of optical and fiber optic PPG and blood oxygen saturation (SpO2) sensors and covers examples of application areas including real-time PPG monitoring from body cavities (esophagus) and solid or hollow organs (bowel, liver, stomach, brain, etc). The clinical studies presented successfully demonstrated the feasibility in acquiring PPGs and estimating blood oxygen saturation values from a variety of organs and tissues. The technological developments and the measurements presented in this work pave the way in a new era of pulse oximetry where direct and continuous monitoring of blood oxygen saturation of internal organs and tissues could be made possible.
Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
Kyriacou, P. A., Hickey, M., & Phillips, J. P. (2013). Pulse oximetry of body cavities and organs. 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2013.6610088
Kyriacou, P. A., M. Hickey, and J. P. Phillips. 2013. "Pulse oximetry of body cavities and organs." 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2013.6610088.
Kyriacou, P. A., Hickey, M. and Phillips, J. P. (2013) 'Pulse oximetry of body cavities and organs', 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. doi: 10.1109/embc.2013.6610088.
Kyriacou, P. A., et al. "Pulse oximetry of body cavities and organs." 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2013. https://doi.org/10.1109/embc.2013.6610088.
P. A. Kyriacou, M. Hickey, and J. P. Phillips, "Pulse oximetry of body cavities and organs," 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2013, doi: 10.1109/embc.2013.6610088.
@inproceedings{kyriacou2013pulse,
title = {{Pulse oximetry of body cavities and organs}},
author = {Kyriacou, P. A. and Hickey, M. and Phillips, J. P.},
year = {2013},
booktitle = {2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society},
doi = {10.1109/embc.2013.6610088}
}Added to the ChatPPG research hub