Pulse oximetry probes placed peripherally may fail to give accurate values of blood oxygen saturation when the peripheral circulation is poor. A reflectance blood oxygen saturation probe was developed and evaluated in 49 patients undergoing cardiothoracic surgery. The oesophageal pulse oximeter results were in good agreement with oxygen saturation measurements obtained by a blood gas analyser, a CO‐oximeter and a commercial finger pulse oximeter.

  • Published in Anaesthesia (2003).

Abstract

Pulse oximetry probes placed peripherally may fail to give accurate values of blood oxygen saturation when the peripheral circulation is poor. Because central blood flow may be preferentially preserved, we investigated the oesophagus as an alternative monitoring site. A reflectance blood oxygen saturation probe was developed and evaluated in 49 patients undergoing cardiothoracic surgery. The oesophageal pulse oximeter results were in good agreement with oxygen saturation measurements obtained by a blood gas analyser, a CO‐oximeter and a commercial finger pulse oximeter. The median (IQR [range]) difference between the oesophageal oxygen saturation results and those from blood gas analysis were 0.00 (−0.30 to 0.30 [−4.47 to 2.60]), and between the oesophageal oxygen saturation results and those from CO‐oximetry were 0.75 (0.30 to 1.20 [−1.80 to 1.80]). Bland–Altman analysis showed that the bias and the limits of agreement between the oesophageal and finger pulse oximeters were −0.3% and −3.3 to 2.7%, respectively. In five (10.2%) patients, the finger pulse oximeter failed for at least 10 min, whereas the oesophageal readings remained reliable. The results suggest that the oesophagus may be used as an alternative monitoring site for pulse oximetry even in patients with compromised peripheral perfusion.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: http://onlinelibrary.wiley.com/termsAndConditions#vor

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

SpO₂

Signals

Keywords

Kyriacou BibliographyPulse Oximetry Oxygenation

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method. Target: SpO₂.SetupSignals: PPGSignalsPPGMethodMethodTargetSpO₂O₂SpO₂

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Kyriacou, P. A., Powell, S. L., Jones, D. P., & Langford, R. M. (2003). Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery*. Anaesthesia. https://doi.org/10.1046/j.1365-2044.2003.03091.x
Kyriacou, P. A., S. L. Powell, D. P. Jones, and R. M. Langford. 2003. "Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery*." Anaesthesia. https://doi.org/10.1046/j.1365-2044.2003.03091.x.
Kyriacou, P. A., Powell, S. L., Jones, D. P. and Langford, R. M. (2003) 'Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery*', Anaesthesia. doi: 10.1046/j.1365-2044.2003.03091.x.
Kyriacou, P. A., et al. "Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery*." Anaesthesia, 2003. https://doi.org/10.1046/j.1365-2044.2003.03091.x.
P. A. Kyriacou, S. L. Powell, D. P. Jones, and R. M. Langford, "Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery*," Anaesthesia, 2003, doi: 10.1046/j.1365-2044.2003.03091.x.
@article{kyriacou2003evaluation,
  title         = {{Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery*}},
  author        = {Kyriacou, P. A. and Powell, S. L. and Jones, D. P. and Langford, R. M.},
  year          = {2003},
  journal       = {Anaesthesia},
  doi           = {10.1046/j.1365-2044.2003.03091.x}
}

Added to the ChatPPG research hub