TL;DR

Pulse oximetry is being used in everyday clinical practice in anesthesia utilizing peripheral saturation sensors. However, it may be unreliable in certain clinical situations such as peripheral hypoperfusion. Similar situations occur in burns patients and more importantly burns to extremities which limit the sites available for measurement of peripheral oxygen saturation (SpO2).

  • Published in 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (2013).

Abstract

Pulse oximetry is being used in everyday clinical practice in anesthesia utilizing peripheral saturation sensors. However, it may be unreliable in certain clinical situations such as peripheral hypoperfusion. Similar situations occur in burns patients and more importantly burns to extremities which limit the sites available for measurement of peripheral oxygen saturation (SpO2). To overcome these limitations, the esophagus has been investigated as an alternative measurement site, as perfusion may be preferentially preserved centrally. A miniaturized reflectance esophageal saturation (SpO2 probe has been constructed utilizing infrared and red photodiodes and a photodetector. Our case study was aimed at evaluating the reliability of esophageal pulse oximetry in a major burns infant. Measurable photoplethysmographic (PPG) traces and SpO2 values were obtained in the neonatal esophagus. It was found that the esophageal pulse oximeter results were in good agreement with oxygen saturation measurements obtained by a commercial ear lobe pulse oximeter. This study suggests that the esophagus can be used as an alternative site for monitoring arterial blood oxygen saturation by pulse oximetry in burned infants.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

SpO₂

Signals

Keywords

Kyriacou BibliographyPulse Oximetry Oxygenation

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method. Target: SpO₂.SetupSignals: PPGSignalsPPGMethodMethodTargetSpO₂O₂SpO₂

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Kyriacou, P. A., May, J. M., & Petros, A. J. (2013). Esophageal SpO<inf>2</inf> measurements from a pediatric burns-patient: A case study. 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2013.6609854
Kyriacou, P. A., J. M. May, and A. J. Petros. 2013. "Esophageal SpO<inf>2</inf> measurements from a pediatric burns-patient: A case study." 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2013.6609854.
Kyriacou, P. A., May, J. M. and Petros, A. J. (2013) 'Esophageal SpO<inf>2</inf> measurements from a pediatric burns-patient: A case study', 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. doi: 10.1109/embc.2013.6609854.
Kyriacou, P. A., et al. "Esophageal SpO<inf>2</inf> measurements from a pediatric burns-patient: A case study." 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2013. https://doi.org/10.1109/embc.2013.6609854.
P. A. Kyriacou, J. M. May, and A. J. Petros, "Esophageal SpO<inf>2</inf> measurements from a pediatric burns-patient: A case study," 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2013, doi: 10.1109/embc.2013.6609854.
@inproceedings{kyriacou2013esophageal,
  title         = {{Esophageal SpO<inf>2</inf> measurements from a pediatric burns-patient: A case study}},
  author        = {Kyriacou, P. A. and May, J. M. and Petros, A. J.},
  year          = {2013},
  booktitle     = {2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society},
  doi           = {10.1109/embc.2013.6609854}
}

Added to the ChatPPG research hub