An In Vivo Investigation of Photoplethysmographic Signals and Preliminary Pulse Oximetry Estimation from the Bowel Using a New Fiberoptic Sensor

Venue listed2011Added Nov 5, 2026

  • MH
  • NS
  • NR
  • RL
  • PK

Authors: Michelle Hickey, Neal Samuels, Nilesh Randive, Richard M. Langford, Panayiotis A. Kyriacou

Anesthesia & Analgesia

TL;DR

The continuous monitoring of splanchnic organ oxygen saturation could make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischemia, multiple organ failure, and, ultimately, death. Current methods for assessing splanchnic perfusion have not been widely accepted for use in the clinical care environment. In an attempt to overcome the limitations of the current techniques, a new fiberoptic photoplethysmographic (PPG)/pulse oximetry sensor was developed as a means of assessing splanchnic organ perfusion during surgery in humans.

  • Published in Anesthesia & Analgesia (2011).

Abstract

BackgroundThe continuous monitoring of splanchnic organ oxygen saturation could make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischemia, multiple organ failure, and, ultimately, death. Current methods for assessing splanchnic perfusion have not been widely accepted for use in the clinical care environment. In an attempt to overcome the limitations of the current techniques, a new fiberoptic photoplethysmographic (PPG)/pulse oximetry sensor was developed as a means of assessing splanchnic organ perfusion during surgery in humans.MethodsA new fiberoptic splanchnic pulse oximeter and an optically identical fiberoptic finger pulse oximeter have been developed. Simultaneous PPG signals and preliminary estimates of arterial oxygen saturation from the bowel (small and large) and finger were obtained in 17 patients (3 men and 14 women) undergoing open laparotomy.ResultsGood quality PPG signals were obtained from the small and large bowel and from the finger in all patients (lower 95% confidence limit for the proportion was 0.64). Comparisons of blood oxygen saturation values acquired when using the splanchnic and the finger fiberoptic sensors and a commercial finger pulse oximeter indicated that there was no statistically significant difference between them (all P>0.454). A Bland and Altman plot of the difference between blood oxygen saturation values from the bowel fiberoptic pulse oximeter and the fiberoptic finger pulse oximeter against their mean showed that the limits of agreement between the 2 pulse oximeters were -3.8% and 4.2% for small bowel measurements, and -3.4% and 4.3% for large bowel measurements. The 95% prediction interval for the difference between the 2 devices was between -4.2% and 4.7%.ConclusionThis study demonstrated that good quality PPG signals can be obtained from the bowel using a new fiberoptic sensor. Further evaluation is required to determine whether fiberoptic pulse oximetry of the bowel may provide a suitable method for monitoring splanchnic perfusion.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

SpO₂

Signals

Keywords

Kyriacou BibliographyPulse Oximetry Oxygenation

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method. Target: SpO₂.SetupSignals: PPGSignalsPPGMethodMethodTargetSpO₂O₂SpO₂

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Hickey, M., Samuels, N., Randive, N., Langford, R. M., & Kyriacou, P. A. (2011). An In Vivo Investigation of Photoplethysmographic Signals and Preliminary Pulse Oximetry Estimation from the Bowel Using a New Fiberoptic Sensor. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e31820f8df3
Hickey, Michelle, Neal Samuels, Nilesh Randive, Richard M. Langford, and Panayiotis A. Kyriacou. 2011. "An In Vivo Investigation of Photoplethysmographic Signals and Preliminary Pulse Oximetry Estimation from the Bowel Using a New Fiberoptic Sensor." Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e31820f8df3.
Hickey, M., Samuels, N., Randive, N., Langford, R. M. and Kyriacou, P. A. (2011) 'An In Vivo Investigation of Photoplethysmographic Signals and Preliminary Pulse Oximetry Estimation from the Bowel Using a New Fiberoptic Sensor', Anesthesia & Analgesia. doi: 10.1213/ane.0b013e31820f8df3.
Hickey, Michelle, et al. "An In Vivo Investigation of Photoplethysmographic Signals and Preliminary Pulse Oximetry Estimation from the Bowel Using a New Fiberoptic Sensor." Anesthesia & Analgesia, 2011. https://doi.org/10.1213/ane.0b013e31820f8df3.
M. Hickey, N. Samuels, N. Randive, R. M. Langford, and P. A. Kyriacou, "An In Vivo Investigation of Photoplethysmographic Signals and Preliminary Pulse Oximetry Estimation from the Bowel Using a New Fiberoptic Sensor," Anesthesia & Analgesia, 2011, doi: 10.1213/ane.0b013e31820f8df3.
@article{hickey2011vivo,
  title         = {{An In Vivo Investigation of Photoplethysmographic Signals and Preliminary Pulse Oximetry Estimation from the Bowel Using a New Fiberoptic Sensor}},
  author        = {Hickey, Michelle and Samuels, Neal and Randive, Nilesh and Langford, Richard M. and Kyriacou, Panayiotis A.},
  year          = {2011},
  journal       = {Anesthesia \& Analgesia},
  doi           = {10.1213/ane.0b013e31820f8df3}
}

Added to the ChatPPG research hub