Paperdoi:10.1007/s10877-011-9302-4
Investigation of photoplethysmographic signals and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor
Journal of Clinical Monitoring and Computing
TL;DR
A dependable continuous readout of splanchnic organ oxygen saturation could flag malperfusion early and might head off multiple organ failure. Monitors available now have not been widely taken up in critical care. Ahead of an indwelling device, this 2011 Journal of Clinical Monitoring and Computing study tests a handheld fiber-optic PPG sensor for SpO2 in splanchnic organs during surgery. A sensor, instrumentation system, and virtual instrument were built for those measurements.
- Published in Journal of Clinical Monitoring and Computing (2011).
Abstract
ObjectiveA reliable, continuous method of monitoring splanchnic organ oxygen saturation could allow for the early detection of malperfusion, and may prevent the onset of multiple organ failure. Current monitoring techniques have not been widely accepted in critical care monitoring. As a preliminary to developing a continuous indwelling device, this study evaluates a new handheld fiber optic photoplethysmographic (PPG) sensor for estimating the blood oxygen saturation (SpO(2)) of splanchnic organs during surgery.MethodsA fiber optic splanchnic PPG sensor, instrumentation system and virtual instrument were developed to facilitate PPG and SpO(2) measurement from splanchnic organs. Following Local Research Ethics Committee approval, the sensor was evaluated on seventeen ASA 1 and 2 patients undergoing open laparotomy. PPG signals were obtained from the large bowel, small bowel, liver and stomach. Simultaneous PPG signals from the finger were also obtained using an identical fiber optic sensor.ResultsGood quality PPG signals with high signal-to-noise (SNR) ratios were obtained from all splanchnic sites under investigation. Analysis of the ac and dc amplitudes of the red and infrared PPG signals showed there to be a statistically significant difference between PPG signals obtained from splanchnic organs with those obtained from the finger (using fiber optic sensors). Estimated SpO(2) values from the splanchnic organs show good agreement with those obtained from the finger using both a fiber optic sensor and a commercial device. Furthermore, the results of a Bland and Altman analysis indicate that fiber optic splanchnic pulse oximetry, particularly of the bowel, may provide a suitable method for monitoring splanchnic organ perfusion.ConclusionThe evaluation of a new fiber optic sensor on anaesthetized patients undergoing laparotomy demonstrated that good quality PPG signals and SpO(2) estimates can be obtained from splanchnic organs. Such a sensor may provide a useful tool for the intraoperative assessment of splanchnic perfusion.
Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
Hickey, M., Samuels, N., Randive, N., Langford, R. M., & Kyriacou, P. A. (2011). Investigation of photoplethysmographic signals and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-011-9302-4
Hickey, Michelle, Neal Samuels, Nilesh Randive, R. M. Langford, and P. A. Kyriacou. 2011. "Investigation of photoplethysmographic signals and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor." Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-011-9302-4.
Hickey, M., Samuels, N., Randive, N., Langford, R. M. and Kyriacou, P. A. (2011) 'Investigation of photoplethysmographic signals and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor', Journal of Clinical Monitoring and Computing. doi: 10.1007/s10877-011-9302-4.
Hickey, Michelle, et al. "Investigation of photoplethysmographic signals and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor." Journal of Clinical Monitoring and Computing, 2011. https://doi.org/10.1007/s10877-011-9302-4.
M. Hickey, N. Samuels, N. Randive, R. M. Langford, and P. A. Kyriacou, "Investigation of photoplethysmographic signals and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor," Journal of Clinical Monitoring and Computing, 2011, doi: 10.1007/s10877-011-9302-4.
@article{hickey2011investigation,
title = {{Investigation of photoplethysmographic signals
and blood oxygen saturation values obtained from human splanchnic organs using a fiber optic sensor}},
author = {Hickey, Michelle and Samuels, Neal and Randive, Nilesh and Langford, R. M. and Kyriacou, P. A.},
year = {2011},
journal = {Journal of Clinical Monitoring and Computing},
doi = {10.1007/s10877-011-9302-4}
}Added to the ChatPPG research hub